{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1464170300"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1464170300","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Terahertz Spectroscopic Breath Analysis as a Viable Analytical Chemical Sensing Technique","abstract":"The ability to quantify trace chemicals in human breath enables the possibility of identifying breath biomarkers to aid in diagnosis. The vast majority of the studies in the analytical breath analysis rely on GC-MS techniques for quantification of the human breath composition1,2,3,4. THz spectroscopy of breath is rapid, sensitive, and highly specific molecular identification in complex mixtures containing 10-100 analytes with near `absolute' specificity. THz spectroscopic breath analyzers require chemical preconcentration. A newly developed custom preconcentrator was constructed and compared in its performance to a commercial system. Unlike the commercial counterpart, the new system does not require cryogenic liquids, is compact, and offers significant advantages in terms of ease of operation and facilitates further development of THz breath sensors. Its preconcentration efficiency was assessed. The THz spectrometer coupled with the custom preconcentrator demonstrated first THz detection of breath isoprene, a chemical not detected with the commercial device.","abstract_html":"The ability to quantify trace chemicals in human breath enables the possibility of identifying breath biomarkers to aid in diagnosis. The vast majority of the studies in the analytical breath analysis rely on GC-MS techniques for quantification of the human breath composition1,2,3,4. THz spectroscopy of breath is rapid, sensitive, and highly specific molecular identification in complex mixtures containing 10-100 analytes with near `absolute&#x27; specificity. THz spectroscopic breath analyzers require chemical preconcentration. A newly developed custom preconcentrator was constructed and compared in its performance to a commercial system. Unlike the commercial counterpart, the new system does not require cryogenic liquids, is compact, and offers significant advantages in terms of ease of operation and facilitates further development of THz breath sensors. Its preconcentration efficiency was assessed. The THz spectrometer coupled with the custom preconcentrator demonstrated first THz detection of breath isoprene, a chemical not detected with the commercial device.","abstract_has_math":false,"creators":["Schueler, Robert M."],"institution":"Wright State University","degree_name":"Master of Science (MS)","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Medvedev , Ivan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-05-27","date_published":"2016-05-27","updated_at":"2026-11-26T05:29:35Z","subjects":["Physics","spectroscopy , TERAHERTZ , Breath,THz, preconcentrator"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1464170300","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1464170300","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1464170300","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1464170300","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Medvedev , Ivan"]},{"key":"dc:creator","label":"Author","values":["Schueler, Robert M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-05-27"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","spectroscopy , TERAHERTZ , Breath,THz, preconcentrator"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1464170300"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The ability to quantify trace chemicals in human breath enables the possibility of identifying breath biomarkers to aid in diagnosis. The vast majority of the studies in the analytical breath analysis rely on GC-MS techniques for quantification of the human breath composition1,2,3,4. THz spectroscopy of breath is rapid, sensitive, and highly specific molecular identification in complex mixtures containing 10-100 analytes with near `absolute' specificity. THz spectroscopic breath analyzers require chemical preconcentration. A newly developed custom preconcentrator was constructed and compared in its performance to a commercial system. Unlike the commercial counterpart, the new system does not require cryogenic liquids, is compact, and offers significant advantages in terms of ease of operation and facilitates further development of THz breath sensors. Its preconcentration efficiency was assessed. The THz spectrometer coupled with the custom preconcentrator demonstrated first THz detection of breath isoprene, a chemical not detected with the commercial device."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.53","2.25 MB"]},{"key":"dc:title","label":"Title","values":["Terahertz Spectroscopic Breath Analysis as a Viable Analytical Chemical Sensing Technique"]}]}],"canonical_facts":{"dc:contributor":["Medvedev , Ivan"],"dc:creator":["Schueler, Robert M."],"dc:date":["2016-05-27"],"dc:description":["The ability to quantify trace chemicals in human breath enables the possibility of identifying breath biomarkers to aid in diagnosis. The vast majority of the studies in the analytical breath analysis rely on GC-MS techniques for quantification of the human breath composition1,2,3,4. THz spectroscopy of breath is rapid, sensitive, and highly specific molecular identification in complex mixtures containing 10-100 analytes with near `absolute' specificity. THz spectroscopic breath analyzers require chemical preconcentration. A newly developed custom preconcentrator was constructed and compared in its performance to a commercial system. Unlike the commercial counterpart, the new system does not require cryogenic liquids, is compact, and offers significant advantages in terms of ease of operation and facilitates further development of THz breath sensors. Its preconcentration efficiency was assessed. The THz spectrometer coupled with the custom preconcentrator demonstrated first THz detection of breath isoprene, a chemical not detected with the commercial device."],"dc:format":["application/pdf","p.53","2.25 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1464170300"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Physics","spectroscopy , TERAHERTZ , Breath,THz, preconcentrator"],"dc:title":["Terahertz Spectroscopic Breath Analysis as a Viable Analytical Chemical Sensing Technique"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science (MS)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T05:29:35Z"}