{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1501711461736129"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1501711461736129","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Identifying the Impact of Noise on Anomaly Detection through Functional Near-Infrared Spectroscopy (fNIRS) and Eye-tracking","abstract":"Occupational noise frequently occurs in the work environment in military intelligence, surveillance, and reconnaissance (ISR) operations. This impacts cognitive performance by acting as a stressor, potentially interfering with the analysts’ decision making process. In this study the effects of different noise stimuli on analysts’ performance and workload in anomaly detection were investigated by simulating a noisy work environment. Functional near infrared spectroscopy (fNIRS) was utilized to quantify oxy-hemoglobin (HbO) and deoxy-hemoglobin (HbD) concentration changes in the prefrontal cortex (PFC), as well as behavioral measures which include eye-tracking, reaction time, and accuracy rate. It was found that HbO for some of the channels analyzed were significantly different across noise types (p<0.05). The results indicated that HbO activation for short intermittent noise stimuli was greater in the PFC compared to long intermittent noises. Target transition rates were also significantly higher (p<0.05) for no noise conditions compared to noise filled environments. These approaches using fNIRS in conjunction with an understanding of the impact on human analysts in anomaly detection, could potentially lead to better performance by optimizing work environments.","abstract_html":"Occupational noise frequently occurs in the work environment in military intelligence, surveillance, and reconnaissance (ISR) operations. This impacts cognitive performance by acting as a stressor, potentially interfering with the analysts’ decision making process. In this study the effects of different noise stimuli on analysts’ performance and workload in anomaly detection were investigated by simulating a noisy work environment. Functional near infrared spectroscopy (fNIRS) was utilized to quantify oxy-hemoglobin (HbO) and deoxy-hemoglobin (HbD) concentration changes in the prefrontal cortex (PFC), as well as behavioral measures which include eye-tracking, reaction time, and accuracy rate. It was found that HbO for some of the channels analyzed were significantly different across noise types (p&lt;0.05). The results indicated that HbO activation for short intermittent noise stimuli was greater in the PFC compared to long intermittent noises. Target transition rates were also significantly higher (p&lt;0.05) for no noise conditions compared to noise filled environments. These approaches using fNIRS in conjunction with an understanding of the impact on human analysts in anomaly detection, could potentially lead to better performance by optimizing work environments.","abstract_has_math":false,"creators":["Gabbard, Ryan Dwight"],"institution":"Wright State University","degree_name":"Master of Science in Biomedical Engineering (MSBME)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Fendley, Mary"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-08-11","date_published":"2017-08-11","updated_at":"2026-11-27T04:48:11Z","subjects":["Neurosciences","Biomedical Engineering","functional near-infrared spectroscopy","workload","prefrontal cortex","eye tracking","noise","anomaly detection"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1501711461736129","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1501711461736129","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1501711461736129","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1501711461736129","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fendley, Mary"]},{"key":"dc:creator","label":"Author","values":["Gabbard, Ryan Dwight"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-08-11"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering (MSBME)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neurosciences","Biomedical Engineering","functional near-infrared spectroscopy","workload","prefrontal cortex","eye tracking","noise","anomaly detection"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1501711461736129"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Occupational noise frequently occurs in the work environment in military intelligence, surveillance, and reconnaissance (ISR) operations. This impacts cognitive performance by acting as a stressor, potentially interfering with the analysts’ decision making process. In this study the effects of different noise stimuli on analysts’ performance and workload in anomaly detection were investigated by simulating a noisy work environment. Functional near infrared spectroscopy (fNIRS) was utilized to quantify oxy-hemoglobin (HbO) and deoxy-hemoglobin (HbD) concentration changes in the prefrontal cortex (PFC), as well as behavioral measures which include eye-tracking, reaction time, and accuracy rate. It was found that HbO for some of the channels analyzed were significantly different across noise types (p<0.05). The results indicated that HbO activation for short intermittent noise stimuli was greater in the PFC compared to long intermittent noises. Target transition rates were also significantly higher (p<0.05) for no noise conditions compared to noise filled environments. These approaches using fNIRS in conjunction with an understanding of the impact on human analysts in anomaly detection, could potentially lead to better performance by optimizing work environments."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.114","3.71 MB"]},{"key":"dc:title","label":"Title","values":["Identifying the Impact of Noise on Anomaly Detection through Functional Near-Infrared Spectroscopy (fNIRS) and Eye-tracking"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fendley, Mary"],"dc:creator":["Gabbard, Ryan Dwight"],"dc:date":["2017-08-11"],"dc:description":["Occupational noise frequently occurs in the work environment in military intelligence, surveillance, and reconnaissance (ISR) operations. This impacts cognitive performance by acting as a stressor, potentially interfering with the analysts’ decision making process. In this study the effects of different noise stimuli on analysts’ performance and workload in anomaly detection were investigated by simulating a noisy work environment. Functional near infrared spectroscopy (fNIRS) was utilized to quantify oxy-hemoglobin (HbO) and deoxy-hemoglobin (HbD) concentration changes in the prefrontal cortex (PFC), as well as behavioral measures which include eye-tracking, reaction time, and accuracy rate. It was found that HbO for some of the channels analyzed were significantly different across noise types (p<0.05). The results indicated that HbO activation for short intermittent noise stimuli was greater in the PFC compared to long intermittent noises. Target transition rates were also significantly higher (p<0.05) for no noise conditions compared to noise filled environments. These approaches using fNIRS in conjunction with an understanding of the impact on human analysts in anomaly detection, could potentially lead to better performance by optimizing work environments."],"dc:format":["application/pdf","p.114","3.71 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1501711461736129"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Neurosciences","Biomedical Engineering","functional near-infrared spectroscopy","workload","prefrontal cortex","eye tracking","noise","anomaly detection"],"dc:title":["Identifying the Impact of Noise on Anomaly Detection through Functional Near-Infrared Spectroscopy (fNIRS) and Eye-tracking"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Engineering (MSBME)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:48:11Z"}