{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1514514772104065"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1514514772104065","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Determination of the Shape of a Flattening Filter Free (FFF) Radiation Beam When Modified by a Physical Wedge","abstract":"The determination of a flattening filter free (FFF) beam profile when the collimator is intentionally modified to incorporate a physical wedge. Specifically, radiation beam profiles change shape when a metallic wedge is placed in the path of the beam. Examination of this unknown is necessary to ascertain whether a physical wedge is clinically beneficial for applications involving FFF beams. The aim of this study is to determine if the radiation profile of a flattening filter free beam having a physical wedge is comparable to a beam with a flattening filter, with the same wedge inserted. This research involves measurement of relative dose along the wedged plane. A commercially available particle accelerator was used for this study, which was capable of producing 6 MV bremsstrahlung x-rays. Only beams operating at 6 MV were considered for the investigation. The results indicate that Wedged profiles are similar in many respects when a FFF beam uses the same physical wedge designed for flattening filter beams. Differences in wedged profiles between the FFF and FF beams are discussed.","abstract_html":"The determination of a flattening filter free (FFF) beam profile when the collimator is intentionally modified to incorporate a physical wedge. Specifically, radiation beam profiles change shape when a metallic wedge is placed in the path of the beam. Examination of this unknown is necessary to ascertain whether a physical wedge is clinically beneficial for applications involving FFF beams. The aim of this study is to determine if the radiation profile of a flattening filter free beam having a physical wedge is comparable to a beam with a flattening filter, with the same wedge inserted. This research involves measurement of relative dose along the wedged plane. A commercially available particle accelerator was used for this study, which was capable of producing 6 MV bremsstrahlung x-rays. Only beams operating at 6 MV were considered for the investigation. The results indicate that Wedged profiles are similar in many respects when a FFF beam uses the same physical wedge designed for flattening filter beams. Differences in wedged profiles between the FFF and FF beams are discussed.","abstract_has_math":false,"creators":["Alsaeed, Kalel"],"institution":"Wright State University","degree_name":"Master of Science (MS)","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":["Foy, Brent"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-27T04:48:23Z","subjects":["Physics","Wedge","FFF beam","FF beam","using wedge with FFF beam"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1514514772104065","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1514514772104065","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1514514772104065","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1514514772104065","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Foy, Brent"]},{"key":"dc:creator","label":"Author","values":["Alsaeed, Kalel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","Wedge","FFF beam","FF beam","using wedge with FFF beam"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1514514772104065"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The determination of a flattening filter free (FFF) beam profile when the collimator is intentionally modified to incorporate a physical wedge. Specifically, radiation beam profiles change shape when a metallic wedge is placed in the path of the beam. Examination of this unknown is necessary to ascertain whether a physical wedge is clinically beneficial for applications involving FFF beams. The aim of this study is to determine if the radiation profile of a flattening filter free beam having a physical wedge is comparable to a beam with a flattening filter, with the same wedge inserted. This research involves measurement of relative dose along the wedged plane. A commercially available particle accelerator was used for this study, which was capable of producing 6 MV bremsstrahlung x-rays. Only beams operating at 6 MV were considered for the investigation. The results indicate that Wedged profiles are similar in many respects when a FFF beam uses the same physical wedge designed for flattening filter beams. Differences in wedged profiles between the FFF and FF beams are discussed."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.59","1.18 MB"]},{"key":"dc:title","label":"Title","values":["Determination of the Shape of a Flattening Filter Free (FFF) Radiation Beam When Modified by a Physical Wedge"]}]}],"canonical_facts":{"dc:contributor.advisor":["Foy, Brent"],"dc:creator":["Alsaeed, Kalel"],"dc:date":["2017"],"dc:description":["The determination of a flattening filter free (FFF) beam profile when the collimator is intentionally modified to incorporate a physical wedge. Specifically, radiation beam profiles change shape when a metallic wedge is placed in the path of the beam. Examination of this unknown is necessary to ascertain whether a physical wedge is clinically beneficial for applications involving FFF beams. The aim of this study is to determine if the radiation profile of a flattening filter free beam having a physical wedge is comparable to a beam with a flattening filter, with the same wedge inserted. This research involves measurement of relative dose along the wedged plane. A commercially available particle accelerator was used for this study, which was capable of producing 6 MV bremsstrahlung x-rays. Only beams operating at 6 MV were considered for the investigation. The results indicate that Wedged profiles are similar in many respects when a FFF beam uses the same physical wedge designed for flattening filter beams. Differences in wedged profiles between the FFF and FF beams are discussed."],"dc:format":["application/pdf","p.59","1.18 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1514514772104065"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Physics","Wedge","FFF beam","FF beam","using wedge with FFF beam"],"dc:title":["Determination of the Shape of a Flattening Filter Free (FFF) Radiation Beam When Modified by a Physical Wedge"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science (MS)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:48:23Z"}