{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1535229803969101"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1535229803969101","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Novel Auto-Calibrating Neural Motor Decoder for Robust Prosthetic Control","abstract":"The overarching goal of this project is to develop novel neural motor decoders for prosthetic control. EMG decoders measure the activity from an intact but non-target muscle. Neural motor decoders transform the signal measured from the severed motor axons of the target muscle. A multi-scale, highly-realistic computer model of a spinal motor pool was developed (Allen & Elbasiouny, 2018) to serve as a computational platform for decoder development and testing. A firing rate-based algorithm was developed to transform the aggregate discharge of the motor pool into a command signal to control the simulated prosthetic MuJoCo hand. This algorithm was informed by cellular neurophysiology knowledge of how motor neurons are activated by synaptic inputs to generate action potentials. Our results show that this neural motor decoder is fast (i.e., decoding time < 10 ms), reliable (i.e., accurate decoding of inputs varying in waveform, magnitude, and speed), and robust (i.e., accurate decoding of varying activation schemes) in controlling the prosthesis. Additionally, this decoder was successful in automatically adapting, in real-time, to dynamic changes in the synaptic input signals and decoding its magnitude and rate of activation; thus, minimizing the need for frequent daily calibrations by the amputee.","abstract_html":"The overarching goal of this project is to develop novel neural motor decoders for prosthetic control. EMG decoders measure the activity from an intact but non-target muscle. Neural motor decoders transform the signal measured from the severed motor axons of the target muscle. A multi-scale, highly-realistic computer model of a spinal motor pool was developed (Allen &amp; Elbasiouny, 2018) to serve as a computational platform for decoder development and testing. A firing rate-based algorithm was developed to transform the aggregate discharge of the motor pool into a command signal to control the simulated prosthetic MuJoCo hand. This algorithm was informed by cellular neurophysiology knowledge of how motor neurons are activated by synaptic inputs to generate action potentials. Our results show that this neural motor decoder is fast (i.e., decoding time &lt; 10 ms), reliable (i.e., accurate decoding of inputs varying in waveform, magnitude, and speed), and robust (i.e., accurate decoding of varying activation schemes) in controlling the prosthesis. Additionally, this decoder was successful in automatically adapting, in real-time, to dynamic changes in the synaptic input signals and decoding its magnitude and rate of activation; thus, minimizing the need for frequent daily calibrations by the amputee.","abstract_has_math":false,"creators":["Montgomery, Andrew Earl"],"institution":"Wright State University","degree_name":"Master of Science in Biomedical Engineering (MSBME)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Elbasiouny, Sherif"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-08-30","date_published":"2018-08-30","updated_at":"2026-11-27T04:48:45Z","subjects":["Biomedical Engineering","Biomedical Research","Neurology","Neural Motor Decoder","Prosthetic","Computational Modeling","Human Machine Interface"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1535229803969101","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1535229803969101","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1535229803969101","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1535229803969101","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Elbasiouny, Sherif"]},{"key":"dc:creator","label":"Author","values":["Montgomery, Andrew Earl"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-08-30"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering (MSBME)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","Neurology","Neural Motor Decoder","Prosthetic","Computational Modeling","Human Machine Interface"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1535229803969101"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The overarching goal of this project is to develop novel neural motor decoders for prosthetic control. EMG decoders measure the activity from an intact but non-target muscle. Neural motor decoders transform the signal measured from the severed motor axons of the target muscle. A multi-scale, highly-realistic computer model of a spinal motor pool was developed (Allen & Elbasiouny, 2018) to serve as a computational platform for decoder development and testing. A firing rate-based algorithm was developed to transform the aggregate discharge of the motor pool into a command signal to control the simulated prosthetic MuJoCo hand. This algorithm was informed by cellular neurophysiology knowledge of how motor neurons are activated by synaptic inputs to generate action potentials. Our results show that this neural motor decoder is fast (i.e., decoding time < 10 ms), reliable (i.e., accurate decoding of inputs varying in waveform, magnitude, and speed), and robust (i.e., accurate decoding of varying activation schemes) in controlling the prosthesis. Additionally, this decoder was successful in automatically adapting, in real-time, to dynamic changes in the synaptic input signals and decoding its magnitude and rate of activation; thus, minimizing the need for frequent daily calibrations by the amputee."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.98","2.24 MB"]},{"key":"dc:title","label":"Title","values":["Novel Auto-Calibrating Neural Motor Decoder for Robust Prosthetic Control"]}]}],"canonical_facts":{"dc:contributor.advisor":["Elbasiouny, Sherif"],"dc:creator":["Montgomery, Andrew Earl"],"dc:date":["2018-08-30"],"dc:description":["The overarching goal of this project is to develop novel neural motor decoders for prosthetic control. EMG decoders measure the activity from an intact but non-target muscle. Neural motor decoders transform the signal measured from the severed motor axons of the target muscle. A multi-scale, highly-realistic computer model of a spinal motor pool was developed (Allen & Elbasiouny, 2018) to serve as a computational platform for decoder development and testing. A firing rate-based algorithm was developed to transform the aggregate discharge of the motor pool into a command signal to control the simulated prosthetic MuJoCo hand. This algorithm was informed by cellular neurophysiology knowledge of how motor neurons are activated by synaptic inputs to generate action potentials. Our results show that this neural motor decoder is fast (i.e., decoding time < 10 ms), reliable (i.e., accurate decoding of inputs varying in waveform, magnitude, and speed), and robust (i.e., accurate decoding of varying activation schemes) in controlling the prosthesis. Additionally, this decoder was successful in automatically adapting, in real-time, to dynamic changes in the synaptic input signals and decoding its magnitude and rate of activation; thus, minimizing the need for frequent daily calibrations by the amputee."],"dc:format":["application/pdf","p.98","2.24 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1535229803969101"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomedical Research","Neurology","Neural Motor Decoder","Prosthetic","Computational Modeling","Human Machine Interface"],"dc:title":["Novel Auto-Calibrating Neural Motor Decoder for Robust Prosthetic Control"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Engineering (MSBME)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:48:45Z"}