{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1547503362869157"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1547503362869157","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Left Ventricular Dynamics and Pulsatile Hemodynamics during Resuscitation of the Fibrillating Heart Using Direct Mechanical Ventricular Actuation","abstract":"The application of mechanical forces during resuscitation of the arrested heart can be used to restore life-sustaining circulation. Open-chest manual massage represents the earliest application of this concept (first described by professor Moritz Schiff in 1874). Many cardiac compression devices have been developed for cardiac support since that time. Direct mechanical ventricular actuation (DMVA) is a non-blood-contacting device that has demonstrated efficacy of providing both systolic and diastolic support. The device encompasses the heart and can provide total circulatory support during ventricular fibrillation (VF) or cardiac arrest. DMVA resuscitative support during VF has been shown to be nontraumatic to the myocardium. Notably, resuscitative support using DMVA has the advantage of generating pulsatile flow without blood contact which benefits vital organ perfusion and post-resuscitation neurologic outcome. However, ventricular and blood flow dynamics during DMVA support have not been well characterized. Specifically, it remains unclear if DMVA support during VF generates ventricular pump function mimicking the native beating heart, or pulsatile flow characteristics similar to the physiological state. The purpose of this dissertation was to better characterize these fundamental aspects of DMVA support during VF. Experimental data herein demonstrate that DMVA support during VF arrest can result in LV pump function similar to the native beating heart and near-physiological pulsatile flow dynamics. The physiological pulsatile flow generated by DMVA may explain DMVA’s capability for improving resuscitation results. A biventricular mock circulatory system (BMCS) incorporating an anatomical mock ventricle provided supportive in vitro data to further confirm these findings.","abstract_html":"The application of mechanical forces during resuscitation of the arrested heart can be used to restore life-sustaining circulation. Open-chest manual massage represents the earliest application of this concept (first described by professor Moritz Schiff in 1874). Many cardiac compression devices have been developed for cardiac support since that time. Direct mechanical ventricular actuation (DMVA) is a non-blood-contacting device that has demonstrated efficacy of providing both systolic and diastolic support. The device encompasses the heart and can provide total circulatory support during ventricular fibrillation (VF) or cardiac arrest. DMVA resuscitative support during VF has been shown to be nontraumatic to the myocardium. Notably, resuscitative support using DMVA has the advantage of generating pulsatile flow without blood contact which benefits vital organ perfusion and post-resuscitation neurologic outcome. However, ventricular and blood flow dynamics during DMVA support have not been well characterized. Specifically, it remains unclear if DMVA support during VF generates ventricular pump function mimicking the native beating heart, or pulsatile flow characteristics similar to the physiological state. The purpose of this dissertation was to better characterize these fundamental aspects of DMVA support during VF. Experimental data herein demonstrate that DMVA support during VF arrest can result in LV pump function similar to the native beating heart and near-physiological pulsatile flow dynamics. The physiological pulsatile flow generated by DMVA may explain DMVA’s capability for improving resuscitation results. A biventricular mock circulatory system (BMCS) incorporating an anatomical mock ventricle provided supportive in vitro data to further confirm these findings.","abstract_has_math":false,"creators":["Zhou, Yirong"],"institution":"Wright State University","degree_name":"Doctor of Philosophy (PhD)","degree_level":"doctoral","degree_discipline":"Biomedical Sciences PhD","degree_department":null,"school":null,"contributors":[],"advisors":["Anstadt, Mark"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-27T04:48:54Z","subjects":["Health Sciences","Biomedical Research","Medical Imaging","Physiology","Direct Mechanical Ventricular Actuation","Speckle Tracking Echocardiography","Myocardial Mechanics","Pump Function","Synchrony","Diastolic Function","Pulsatility","Ventricular Fibrillation","Cardiac Arrest","Resuscitation","Biventricular Mock Circulatory System"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1547503362869157","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1547503362869157","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1547503362869157","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1547503362869157","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Anstadt, Mark"]},{"key":"dc:creator","label":"Author","values":["Zhou, Yirong"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Sciences PhD"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health Sciences","Biomedical Research","Medical Imaging","Physiology","Direct Mechanical Ventricular Actuation","Speckle Tracking Echocardiography","Myocardial Mechanics","Pump Function","Synchrony","Diastolic Function","Pulsatility","Ventricular Fibrillation","Cardiac Arrest","Resuscitation","Biventricular Mock Circulatory System"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1547503362869157"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The application of mechanical forces during resuscitation of the arrested heart can be used to restore life-sustaining circulation. Open-chest manual massage represents the earliest application of this concept (first described by professor Moritz Schiff in 1874). Many cardiac compression devices have been developed for cardiac support since that time. Direct mechanical ventricular actuation (DMVA) is a non-blood-contacting device that has demonstrated efficacy of providing both systolic and diastolic support. The device encompasses the heart and can provide total circulatory support during ventricular fibrillation (VF) or cardiac arrest. DMVA resuscitative support during VF has been shown to be nontraumatic to the myocardium. Notably, resuscitative support using DMVA has the advantage of generating pulsatile flow without blood contact which benefits vital organ perfusion and post-resuscitation neurologic outcome. However, ventricular and blood flow dynamics during DMVA support have not been well characterized. Specifically, it remains unclear if DMVA support during VF generates ventricular pump function mimicking the native beating heart, or pulsatile flow characteristics similar to the physiological state. The purpose of this dissertation was to better characterize these fundamental aspects of DMVA support during VF. Experimental data herein demonstrate that DMVA support during VF arrest can result in LV pump function similar to the native beating heart and near-physiological pulsatile flow dynamics. The physiological pulsatile flow generated by DMVA may explain DMVA’s capability for improving resuscitation results. A biventricular mock circulatory system (BMCS) incorporating an anatomical mock ventricle provided supportive in vitro data to further confirm these findings."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.214","4.96 MB"]},{"key":"dc:title","label":"Title","values":["Left Ventricular Dynamics and Pulsatile Hemodynamics during Resuscitation of the Fibrillating Heart Using Direct Mechanical Ventricular Actuation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Anstadt, Mark"],"dc:creator":["Zhou, Yirong"],"dc:date":["2018"],"dc:description":["The application of mechanical forces during resuscitation of the arrested heart can be used to restore life-sustaining circulation. Open-chest manual massage represents the earliest application of this concept (first described by professor Moritz Schiff in 1874). Many cardiac compression devices have been developed for cardiac support since that time. Direct mechanical ventricular actuation (DMVA) is a non-blood-contacting device that has demonstrated efficacy of providing both systolic and diastolic support. The device encompasses the heart and can provide total circulatory support during ventricular fibrillation (VF) or cardiac arrest. DMVA resuscitative support during VF has been shown to be nontraumatic to the myocardium. Notably, resuscitative support using DMVA has the advantage of generating pulsatile flow without blood contact which benefits vital organ perfusion and post-resuscitation neurologic outcome. However, ventricular and blood flow dynamics during DMVA support have not been well characterized. Specifically, it remains unclear if DMVA support during VF generates ventricular pump function mimicking the native beating heart, or pulsatile flow characteristics similar to the physiological state. The purpose of this dissertation was to better characterize these fundamental aspects of DMVA support during VF. Experimental data herein demonstrate that DMVA support during VF arrest can result in LV pump function similar to the native beating heart and near-physiological pulsatile flow dynamics. The physiological pulsatile flow generated by DMVA may explain DMVA’s capability for improving resuscitation results. A biventricular mock circulatory system (BMCS) incorporating an anatomical mock ventricle provided supportive in vitro data to further confirm these findings."],"dc:format":["application/pdf","p.214","4.96 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1547503362869157"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Health Sciences","Biomedical Research","Medical Imaging","Physiology","Direct Mechanical Ventricular Actuation","Speckle Tracking Echocardiography","Myocardial Mechanics","Pump Function","Synchrony","Diastolic Function","Pulsatility","Ventricular Fibrillation","Cardiac Arrest","Resuscitation","Biventricular Mock Circulatory System"],"dc:title":["Left Ventricular Dynamics and Pulsatile Hemodynamics during Resuscitation of the Fibrillating Heart Using Direct Mechanical Ventricular Actuation"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Sciences PhD"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy (PhD)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:48:54Z"}