{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1558645340226381"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1558645340226381","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Computational Simulation of a Femoral Nail Fracture","abstract":"Every year in the United States roughly 300,000 people over the age of 65 suffer from a hip fracture. Ninety five percent of which are the result from a fall. The resulting hip fracture can be classified into several categories of fracture. Depending on the damage the patient could be implanted with a femoral nail device to assist in their recovery. These devices can, however, have complications during recovery. In some cases, these nails can have a failure rate as high as 10%. When failure occurs, extensive investigations are needed to determine the causes of failure. These investigations involve physical examination, testing for material and chemical properties, and numerical computation with computer simulations. The results from this investigation show that the nail investigated may have accrued damage from the implantation process. There is evidence of internal crack propagation leading to device failure. Simulations performed indicate that if the nail was operating in a femur with a subtrochanteric fracture the internal forces may have been 50% higher than that of a normal femur, significantly more than any fracture type.","abstract_html":"Every year in the United States roughly 300,000 people over the age of 65 suffer from a hip fracture. Ninety five percent of which are the result from a fall. The resulting hip fracture can be classified into several categories of fracture. Depending on the damage the patient could be implanted with a femoral nail device to assist in their recovery. These devices can, however, have complications during recovery. In some cases, these nails can have a failure rate as high as 10%. When failure occurs, extensive investigations are needed to determine the causes of failure. These investigations involve physical examination, testing for material and chemical properties, and numerical computation with computer simulations. The results from this investigation show that the nail investigated may have accrued damage from the implantation process. There is evidence of internal crack propagation leading to device failure. Simulations performed indicate that if the nail was operating in a femur with a subtrochanteric fracture the internal forces may have been 50% higher than that of a normal femur, significantly more than any fracture type.","abstract_has_math":false,"creators":["Whatley, Stephen Charles"],"institution":"Wright State University","degree_name":"Master of Science in Biomedical Engineering (MSBME)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Goswami, Tarun"],"committee_members":[],"year":2019,"date_issued":"2019-05-24","date_published":"2019-05-24","updated_at":"2026-11-27T04:49:11Z","subjects":["Biomedical Engineering","Hip implant","FEA","failure analysis","femoral nail"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1558645340226381","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1558645340226381","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1558645340226381","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1558645340226381","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Goswami, Tarun"]},{"key":"dc:creator","label":"Author","values":["Whatley, Stephen Charles"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-05-24"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering (MSBME)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Hip implant","FEA","failure analysis","femoral nail"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1558645340226381"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Every year in the United States roughly 300,000 people over the age of 65 suffer from a hip fracture. Ninety five percent of which are the result from a fall. The resulting hip fracture can be classified into several categories of fracture. Depending on the damage the patient could be implanted with a femoral nail device to assist in their recovery. These devices can, however, have complications during recovery. In some cases, these nails can have a failure rate as high as 10%. When failure occurs, extensive investigations are needed to determine the causes of failure. These investigations involve physical examination, testing for material and chemical properties, and numerical computation with computer simulations. The results from this investigation show that the nail investigated may have accrued damage from the implantation process. There is evidence of internal crack propagation leading to device failure. Simulations performed indicate that if the nail was operating in a femur with a subtrochanteric fracture the internal forces may have been 50% higher than that of a normal femur, significantly more than any fracture type."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.93","3.36 MB"]},{"key":"dc:title","label":"Title","values":["Computational Simulation of a Femoral Nail Fracture"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Goswami, Tarun"],"dc:creator":["Whatley, Stephen Charles"],"dc:date":["2019-05-24"],"dc:description":["Every year in the United States roughly 300,000 people over the age of 65 suffer from a hip fracture. Ninety five percent of which are the result from a fall. The resulting hip fracture can be classified into several categories of fracture. Depending on the damage the patient could be implanted with a femoral nail device to assist in their recovery. These devices can, however, have complications during recovery. In some cases, these nails can have a failure rate as high as 10%. When failure occurs, extensive investigations are needed to determine the causes of failure. These investigations involve physical examination, testing for material and chemical properties, and numerical computation with computer simulations. The results from this investigation show that the nail investigated may have accrued damage from the implantation process. There is evidence of internal crack propagation leading to device failure. Simulations performed indicate that if the nail was operating in a femur with a subtrochanteric fracture the internal forces may have been 50% higher than that of a normal femur, significantly more than any fracture type."],"dc:format":["application/pdf","p.93","3.36 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1558645340226381"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Biomedical Engineering","Hip implant","FEA","failure analysis","femoral nail"],"dc:title":["Computational Simulation of a Femoral Nail Fracture"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Engineering (MSBME)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:49:11Z"}