{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1637169598865539"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1637169598865539","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Time Domain Diffuse Correlation Spectroscopy for Depth-Resolved Cerebral Blood Flow","abstract":"Measuring cerebral blood flow (CBF) is a crucial element in monitoring a vast variety of human brain disorders. Current imaging modalities used for measuring CBF has various limitations that restricts its usefulness especially in the neuroscience intensive care unit (NSICU). Here, the use of Time-gated DCS (TG-DCS) which has significant advantages compared to its predecessor, CW-DCS, was proposed as the solution. However, this technology is still in its infancy and its clinical capability has yet to be established. To show the feasibility of deploying TG-DCS in NSICU settings, the time-domain analytical model for TG-DCS was expanded for multi-layered cases. Next, CW-DCS was validated in humans and in NSICU settings on patients suffering from Traumatic Brain Injury (TBI). A prototype 1064nm TG-DCS system was built and validated on several in-vivo experiments. Finally, the feasibility of the system was shown by deploying it in NSICU settings for measuring CBF in TBI patients. Lastly, deep learning was used to show the feasibility of obtaining real-time results.","abstract_html":"Measuring cerebral blood flow (CBF) is a crucial element in monitoring a vast variety of human brain disorders. Current imaging modalities used for measuring CBF has various limitations that restricts its usefulness especially in the neuroscience intensive care unit (NSICU). Here, the use of Time-gated DCS (TG-DCS) which has significant advantages compared to its predecessor, CW-DCS, was proposed as the solution. However, this technology is still in its infancy and its clinical capability has yet to be established. To show the feasibility of deploying TG-DCS in NSICU settings, the time-domain analytical model for TG-DCS was expanded for multi-layered cases. Next, CW-DCS was validated in humans and in NSICU settings on patients suffering from Traumatic Brain Injury (TBI). A prototype 1064nm TG-DCS system was built and validated on several in-vivo experiments. Finally, the feasibility of the system was shown by deploying it in NSICU settings for measuring CBF in TBI patients. Lastly, deep learning was used to show the feasibility of obtaining real-time results.","abstract_has_math":false,"creators":["Poon, Chien Sing"],"institution":"Wright State University","degree_name":"Doctor of Philosophy (PhD)","degree_level":"doctoral","degree_discipline":"Engineering PhD","degree_department":null,"school":null,"contributors":[],"advisors":["Sunar, Ulas"],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-12-17","date_published":"2021-12-17","updated_at":"2026-11-27T04:50:29Z","subjects":["Artificial Intelligence","Biomedical Engineering","Biomedical Research","Biophysics","Medical Imaging","Neurosciences","Optics","diffuse correlation spectroscopy","optical imaging","traumatic brain injury","cerebral blood flow","diffuse optical spectroscopy","infrared imaging","SWIR","deep learning"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1637169598865539","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1637169598865539","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1637169598865539","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1637169598865539","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sunar, Ulas"]},{"key":"dc:creator","label":"Author","values":["Poon, Chien Sing"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-12-17"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering PhD"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Artificial Intelligence","Biomedical Engineering","Biomedical Research","Biophysics","Medical Imaging","Neurosciences","Optics","diffuse correlation spectroscopy","optical imaging","traumatic brain injury","cerebral blood flow","diffuse optical spectroscopy","infrared imaging","SWIR","deep learning"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1637169598865539"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Measuring cerebral blood flow (CBF) is a crucial element in monitoring a vast variety of human brain disorders. Current imaging modalities used for measuring CBF has various limitations that restricts its usefulness especially in the neuroscience intensive care unit (NSICU). Here, the use of Time-gated DCS (TG-DCS) which has significant advantages compared to its predecessor, CW-DCS, was proposed as the solution. However, this technology is still in its infancy and its clinical capability has yet to be established. To show the feasibility of deploying TG-DCS in NSICU settings, the time-domain analytical model for TG-DCS was expanded for multi-layered cases. Next, CW-DCS was validated in humans and in NSICU settings on patients suffering from Traumatic Brain Injury (TBI). A prototype 1064nm TG-DCS system was built and validated on several in-vivo experiments. Finally, the feasibility of the system was shown by deploying it in NSICU settings for measuring CBF in TBI patients. Lastly, deep learning was used to show the feasibility of obtaining real-time results."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.137","5.74 MB"]},{"key":"dc:title","label":"Title","values":["Time Domain Diffuse Correlation Spectroscopy for Depth-Resolved Cerebral Blood Flow"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sunar, Ulas"],"dc:creator":["Poon, Chien Sing"],"dc:date":["2021-12-17"],"dc:description":["Measuring cerebral blood flow (CBF) is a crucial element in monitoring a vast variety of human brain disorders. Current imaging modalities used for measuring CBF has various limitations that restricts its usefulness especially in the neuroscience intensive care unit (NSICU). Here, the use of Time-gated DCS (TG-DCS) which has significant advantages compared to its predecessor, CW-DCS, was proposed as the solution. However, this technology is still in its infancy and its clinical capability has yet to be established. To show the feasibility of deploying TG-DCS in NSICU settings, the time-domain analytical model for TG-DCS was expanded for multi-layered cases. Next, CW-DCS was validated in humans and in NSICU settings on patients suffering from Traumatic Brain Injury (TBI). A prototype 1064nm TG-DCS system was built and validated on several in-vivo experiments. Finally, the feasibility of the system was shown by deploying it in NSICU settings for measuring CBF in TBI patients. Lastly, deep learning was used to show the feasibility of obtaining real-time results."],"dc:format":["application/pdf","p.137","5.74 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1637169598865539"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Artificial Intelligence","Biomedical Engineering","Biomedical Research","Biophysics","Medical Imaging","Neurosciences","Optics","diffuse correlation spectroscopy","optical imaging","traumatic brain injury","cerebral blood flow","diffuse optical spectroscopy","infrared imaging","SWIR","deep learning"],"dc:title":["Time Domain Diffuse Correlation Spectroscopy for Depth-Resolved Cerebral Blood Flow"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering PhD"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy (PhD)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:50:29Z"}