{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1683207980122164"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1683207980122164","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Monitoring Blood Flow in Animal Models Using a Camera-Based Technique","abstract":"Blood flow dynamics plays a critical role in maintaining tissue health, as it delivers nutrients and oxygen while removing waste products. It is especially important when there is a disruption in cerebral autoregulation due to trauma, which can induce ischemia or hyperemia and can lead to secondary brain injury. Thus, there is a need for noninvasive techniques that can allow continuous monitoring of blood flow during intervention. Optical techniques have become increasingly practical for measuring blood flow due to their non-invasive, continuous, and relatively lower-cost nature. This research focused on developing a low-cost, scalable optical technique for measuring blood flow by implementing speckle contrast optical spectroscopy using a fiber-camera-based approach. This technique is particularly well-suited for measuring blood flow in deep tissues, such as the brain, which is challenging to access using traditional optical methods. A two-channel continuous wave speckle contrast optical spectroscopy device was developed, and the device was rigorously tested using phantoms. Then, it is applied to monitor blood flow changes in the brain following traumatic brain injury (TBI) in mice. The results indicate that trauma-induced significant blood flow decreases consistent with the recent literature. Overall, this approach provides noninvasive continuous measurements of blood flow in preclinical models such as traumatic brain injury.","abstract_html":"Blood flow dynamics plays a critical role in maintaining tissue health, as it delivers nutrients and oxygen while removing waste products. It is especially important when there is a disruption in cerebral autoregulation due to trauma, which can induce ischemia or hyperemia and can lead to secondary brain injury. Thus, there is a need for noninvasive techniques that can allow continuous monitoring of blood flow during intervention. Optical techniques have become increasingly practical for measuring blood flow due to their non-invasive, continuous, and relatively lower-cost nature. This research focused on developing a low-cost, scalable optical technique for measuring blood flow by implementing speckle contrast optical spectroscopy using a fiber-camera-based approach. This technique is particularly well-suited for measuring blood flow in deep tissues, such as the brain, which is challenging to access using traditional optical methods. A two-channel continuous wave speckle contrast optical spectroscopy device was developed, and the device was rigorously tested using phantoms. Then, it is applied to monitor blood flow changes in the brain following traumatic brain injury (TBI) in mice. The results indicate that trauma-induced significant blood flow decreases consistent with the recent literature. Overall, this approach provides noninvasive continuous measurements of blood flow in preclinical models such as traumatic brain injury.","abstract_has_math":false,"creators":["Langri, Dharminder Singh"],"institution":"Wright State University","degree_name":"Doctor of Philosophy (PhD)","degree_level":"doctoral","degree_discipline":"Engineering PhD","degree_department":null,"school":null,"contributors":[],"advisors":["Sunar, Ulas"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-05-09","date_published":"2023-05-09","updated_at":"2026-11-27T04:58:46Z","subjects":["Biomedical Engineering","Biomedical Research","Engineering","Biophysics","Optics","Camera","Fiber","DCS","Diffuse correlation spectroscopy","sCMOS","High Density","Laser Speckle Contrast Imaging","Cerebral Blood Flow","Blood Flow","Continuous Wave","In-Vivo","Dynamic Flow Phantom","Traumatic Brain Injury","Muscular Dystrophy","Non-invasive","Long term monitoring","Intra-operative","Portable","Cheap","Imaging Fiber","bedside monitoring"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1683207980122164","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1683207980122164","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1683207980122164","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1683207980122164","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sunar, Ulas"]},{"key":"dc:creator","label":"Author","values":["Langri, Dharminder Singh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-05-09"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering PhD"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","Engineering","Biophysics","Optics","Camera","Fiber","DCS","Diffuse correlation spectroscopy","sCMOS","High Density","Laser Speckle Contrast Imaging","Cerebral Blood Flow","Blood Flow","Continuous Wave","In-Vivo","Dynamic Flow Phantom","Traumatic Brain Injury","Muscular Dystrophy","Non-invasive","Long term monitoring","Intra-operative","Portable","Cheap","Imaging Fiber","bedside monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1683207980122164"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Blood flow dynamics plays a critical role in maintaining tissue health, as it delivers nutrients and oxygen while removing waste products. It is especially important when there is a disruption in cerebral autoregulation due to trauma, which can induce ischemia or hyperemia and can lead to secondary brain injury. Thus, there is a need for noninvasive techniques that can allow continuous monitoring of blood flow during intervention. Optical techniques have become increasingly practical for measuring blood flow due to their non-invasive, continuous, and relatively lower-cost nature. This research focused on developing a low-cost, scalable optical technique for measuring blood flow by implementing speckle contrast optical spectroscopy using a fiber-camera-based approach. This technique is particularly well-suited for measuring blood flow in deep tissues, such as the brain, which is challenging to access using traditional optical methods. A two-channel continuous wave speckle contrast optical spectroscopy device was developed, and the device was rigorously tested using phantoms. Then, it is applied to monitor blood flow changes in the brain following traumatic brain injury (TBI) in mice. The results indicate that trauma-induced significant blood flow decreases consistent with the recent literature. Overall, this approach provides noninvasive continuous measurements of blood flow in preclinical models such as traumatic brain injury."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.79","2.06 MB"]},{"key":"dc:title","label":"Title","values":["Monitoring Blood Flow in Animal Models Using a Camera-Based Technique"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sunar, Ulas"],"dc:creator":["Langri, Dharminder Singh"],"dc:date":["2023-05-09"],"dc:description":["Blood flow dynamics plays a critical role in maintaining tissue health, as it delivers nutrients and oxygen while removing waste products. It is especially important when there is a disruption in cerebral autoregulation due to trauma, which can induce ischemia or hyperemia and can lead to secondary brain injury. Thus, there is a need for noninvasive techniques that can allow continuous monitoring of blood flow during intervention. Optical techniques have become increasingly practical for measuring blood flow due to their non-invasive, continuous, and relatively lower-cost nature. This research focused on developing a low-cost, scalable optical technique for measuring blood flow by implementing speckle contrast optical spectroscopy using a fiber-camera-based approach. This technique is particularly well-suited for measuring blood flow in deep tissues, such as the brain, which is challenging to access using traditional optical methods. A two-channel continuous wave speckle contrast optical spectroscopy device was developed, and the device was rigorously tested using phantoms. Then, it is applied to monitor blood flow changes in the brain following traumatic brain injury (TBI) in mice. The results indicate that trauma-induced significant blood flow decreases consistent with the recent literature. Overall, this approach provides noninvasive continuous measurements of blood flow in preclinical models such as traumatic brain injury."],"dc:format":["application/pdf","p.79","2.06 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1683207980122164"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Biomedical Engineering","Biomedical Research","Engineering","Biophysics","Optics","Camera","Fiber","DCS","Diffuse correlation spectroscopy","sCMOS","High Density","Laser Speckle Contrast Imaging","Cerebral Blood Flow","Blood Flow","Continuous Wave","In-Vivo","Dynamic Flow Phantom","Traumatic Brain Injury","Muscular Dystrophy","Non-invasive","Long term monitoring","Intra-operative","Portable","Cheap","Imaging Fiber","bedside monitoring"],"dc:title":["Monitoring Blood Flow in Animal Models Using a Camera-Based Technique"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering PhD"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy (PhD)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:58:46Z"}