{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ysu1296334599"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ysu1296334599","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A Study of Strain Elastography Under a Normal Tensile Testing Condition","abstract":"Optical elastography is a new imaging modality that is capable of estimating mechanical properties of a deformed object. However, the current method only provides a relative strain distribution map that may not be adequate for certain medical applications. In this investigation, biomechanical tensile testing is used to calibrate theoptical elastogram to estimate the absolute Young’s modulus values. This study has two features: (i) Both treated and controlled samples were examined; (ii) Optical flow and strain algorithms were used to compute motion and strain images that characterize tissue property changes during all stages of deformation (liner, plastic and post – rupture). The findings of this study demonstrate that a calibrated optical elastography is a very promising technique to quantify tissue properties <i>in vivo</i>.","abstract_html":"Optical elastography is a new imaging modality that is capable of estimating mechanical properties of a deformed object. However, the current method only provides a relative strain distribution map that may not be adequate for certain medical applications. In this investigation, biomechanical tensile testing is used to calibrate theoptical elastogram to estimate the absolute Young’s modulus values. This study has two features: (i) Both treated and controlled samples were examined; (ii) Optical flow and strain algorithms were used to compute motion and strain images that characterize tissue property changes during all stages of deformation (liner, plastic and post – rupture). The findings of this study demonstrate that a calibrated optical elastography is a very promising technique to quantify tissue properties &lt;i&gt;in vivo&lt;/i&gt;.","abstract_has_math":false,"creators":["Kukatla, Harish C."],"institution":"Youngstown State University","degree_name":"Master of Computing and Information Systems","degree_level":"masters","degree_discipline":"Department of Computer Science and Information Systems","degree_department":null,"school":null,"contributors":[],"advisors":["Zhang, Yong"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-27T04:38:36Z","subjects":["Biomedical Research","Computer Science","Materials Science","Mechanical Engineering","bio-mechanical analysis of a soft tissue","optical elastography","image analysis of a soft tissue","study of elastography"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ysu1296334599","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ysu1296334599","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aysu1296334599","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aysu1296334599","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zhang, Yong"]},{"key":"dc:creator","label":"Author","values":["Kukatla, Harish C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Youngstown State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Computer Science and Information Systems"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Computing and Information Systems"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Youngstown State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Computer Science","Materials Science","Mechanical Engineering","bio-mechanical analysis of a soft tissue","optical elastography","image analysis of a soft tissue","study of elastography"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ysu1296334599"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Optical elastography is a new imaging modality that is capable of estimating mechanical properties of a deformed object. However, the current method only provides a relative strain distribution map that may not be adequate for certain medical applications. In this investigation, biomechanical tensile testing is used to calibrate theoptical elastogram to estimate the absolute Young’s modulus values. This study has two features: (i) Both treated and controlled samples were examined; (ii) Optical flow and strain algorithms were used to compute motion and strain images that characterize tissue property changes during all stages of deformation (liner, plastic and post – rupture). The findings of this study demonstrate that a calibrated optical elastography is a very promising technique to quantify tissue properties <i>in vivo</i>."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.21","1.04 MB"]},{"key":"dc:title","label":"Title","values":["A Study of Strain Elastography Under a Normal Tensile Testing Condition"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zhang, Yong"],"dc:creator":["Kukatla, Harish C."],"dc:date":["2010"],"dc:description":["Optical elastography is a new imaging modality that is capable of estimating mechanical properties of a deformed object. However, the current method only provides a relative strain distribution map that may not be adequate for certain medical applications. In this investigation, biomechanical tensile testing is used to calibrate theoptical elastogram to estimate the absolute Young’s modulus values. This study has two features: (i) Both treated and controlled samples were examined; (ii) Optical flow and strain algorithms were used to compute motion and strain images that characterize tissue property changes during all stages of deformation (liner, plastic and post – rupture). The findings of this study demonstrate that a calibrated optical elastography is a very promising technique to quantify tissue properties <i>in vivo</i>."],"dc:format":["application/pdf","p.21","1.04 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ysu1296334599"],"dc:language":["English"],"dc:publisher":["Youngstown State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Computer Science","Materials Science","Mechanical Engineering","bio-mechanical analysis of a soft tissue","optical elastography","image analysis of a soft tissue","study of elastography"],"dc:title":["A Study of Strain Elastography Under a Normal Tensile Testing Condition"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Department of Computer Science and Information Systems"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Computing and Information Systems"],"thesis:institution_name":["Youngstown State University"]},"updated_at":"2026-11-27T04:38:36Z"}