{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ysu1403036613"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ysu1403036613","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Controlling Condensate Outlet Temperature on an Air Cooled Condenser in MATLAB/Simulink","abstract":"With an ever increasing electrical power demand, the importance of plant simulations remains important for both personnel training and system design. Individual components may be modeled alone to analyze performance of a specific subsystem. One such subsystem of interest is an Air Cooled Condenser (ACC), as it provides an ideal cooling solution to those power plants subjected to strict water usage requirements as well as those lacking a sufficient nearby water source. An ACC was modeled for simulation in MATLAB/Simulink. The goal of the simulation was to successfully implement a triple cascade control that could maintain the condensate outlet temperature at a designated value. The physical portion of the model consists of three node types: steam/water nodes, metal nodes (pipe wall), and air nodes. The control portion of the model employs a triple cascade control with the use of PID control blocks. There were three variables used to control the temperature; steam extraction percentage, fan speed percentage, and air recirculation percentage. The simulation was then tested under various transient conditions. At present time the physical model is performing exceptionally and the controls sufficiently maintain the desired values under certain conditions, however transient responses require additional tuning. Limitations of the model are addressed and areas for future work are suggested.","abstract_html":"With an ever increasing electrical power demand, the importance of plant simulations remains important for both personnel training and system design. Individual components may be modeled alone to analyze performance of a specific subsystem. One such subsystem of interest is an Air Cooled Condenser (ACC), as it provides an ideal cooling solution to those power plants subjected to strict water usage requirements as well as those lacking a sufficient nearby water source. An ACC was modeled for simulation in MATLAB/Simulink. The goal of the simulation was to successfully implement a triple cascade control that could maintain the condensate outlet temperature at a designated value. The physical portion of the model consists of three node types: steam/water nodes, metal nodes (pipe wall), and air nodes. The control portion of the model employs a triple cascade control with the use of PID control blocks. There were three variables used to control the temperature; steam extraction percentage, fan speed percentage, and air recirculation percentage. The simulation was then tested under various transient conditions. At present time the physical model is performing exceptionally and the controls sufficiently maintain the desired values under certain conditions, however transient responses require additional tuning. Limitations of the model are addressed and areas for future work are suggested.","abstract_has_math":false,"creators":["Hyden, Kathryn R."],"institution":"Youngstown State University","degree_name":"Master of Science in Engineering","degree_level":"masters","degree_discipline":"Department of Mechanical, Industrial and Manufacturing Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Marie, Hazel"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-06-18","date_published":"2014-06-18","updated_at":"2026-11-27T04:39:45Z","subjects":["Engineering","Mechanical Engineering","condenser","ACC","controls","MATLAB","Simulink"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ysu1403036613","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ysu1403036613","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aysu1403036613","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aysu1403036613","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marie, Hazel"]},{"key":"dc:creator","label":"Author","values":["Hyden, Kathryn R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-06-18"]},{"key":"dc:publisher","label":"Institution","values":["Youngstown State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Department of Mechanical, Industrial and Manufacturing Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Youngstown State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Mechanical Engineering","condenser","ACC","controls","MATLAB","Simulink"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ysu1403036613"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["With an ever increasing electrical power demand, the importance of plant simulations remains important for both personnel training and system design. Individual components may be modeled alone to analyze performance of a specific subsystem. One such subsystem of interest is an Air Cooled Condenser (ACC), as it provides an ideal cooling solution to those power plants subjected to strict water usage requirements as well as those lacking a sufficient nearby water source. An ACC was modeled for simulation in MATLAB/Simulink. The goal of the simulation was to successfully implement a triple cascade control that could maintain the condensate outlet temperature at a designated value. The physical portion of the model consists of three node types: steam/water nodes, metal nodes (pipe wall), and air nodes. The control portion of the model employs a triple cascade control with the use of PID control blocks. There were three variables used to control the temperature; steam extraction percentage, fan speed percentage, and air recirculation percentage. The simulation was then tested under various transient conditions. At present time the physical model is performing exceptionally and the controls sufficiently maintain the desired values under certain conditions, however transient responses require additional tuning. Limitations of the model are addressed and areas for future work are suggested."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.134","2.35 MB"]},{"key":"dc:title","label":"Title","values":["Controlling Condensate Outlet Temperature on an Air Cooled Condenser in MATLAB/Simulink"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marie, Hazel"],"dc:creator":["Hyden, Kathryn R."],"dc:date":["2014-06-18"],"dc:description":["With an ever increasing electrical power demand, the importance of plant simulations remains important for both personnel training and system design. Individual components may be modeled alone to analyze performance of a specific subsystem. One such subsystem of interest is an Air Cooled Condenser (ACC), as it provides an ideal cooling solution to those power plants subjected to strict water usage requirements as well as those lacking a sufficient nearby water source. An ACC was modeled for simulation in MATLAB/Simulink. The goal of the simulation was to successfully implement a triple cascade control that could maintain the condensate outlet temperature at a designated value. The physical portion of the model consists of three node types: steam/water nodes, metal nodes (pipe wall), and air nodes. The control portion of the model employs a triple cascade control with the use of PID control blocks. There were three variables used to control the temperature; steam extraction percentage, fan speed percentage, and air recirculation percentage. The simulation was then tested under various transient conditions. At present time the physical model is performing exceptionally and the controls sufficiently maintain the desired values under certain conditions, however transient responses require additional tuning. Limitations of the model are addressed and areas for future work are suggested."],"dc:format":["application/pdf","p.134","2.35 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ysu1403036613"],"dc:language":["English"],"dc:publisher":["Youngstown State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering","Mechanical Engineering","condenser","ACC","controls","MATLAB","Simulink"],"dc:title":["Controlling Condensate Outlet Temperature on an Air Cooled Condenser in MATLAB/Simulink"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Department of Mechanical, Industrial and Manufacturing Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering"],"thesis:institution_name":["Youngstown State University"]},"updated_at":"2026-11-27T04:39:45Z"}