{"id":{"repo_id":"oldenburg","oai_identifier":"oai:oops.uni-oldenburg.de:1631"},"canonical_url":"https://search.ndltd.org/etd/oldenburg/oai:oops.uni-oldenburg.de:1631","repository":{"repo_id":"oldenburg","name":"Carl von Ossietzky Universität Oldenburg","base_url":"http://oops.uni-oldenburg.de/cgi/oai2"},"display":{"title":"Spectrally and spatially resolved photoluminescence: lateral fluctuations and depth profiles of Cu(In,Ga)Se2-absorbers","abstract":"The aim of this thesis is the development and refinement of photoluminescence (PL) methods for inhomogeneous absorbers to identify lateral fluctuations and depth-dependent variations of spectroscopic, optical and opto-electronic properties in the submicron/micron range. The first approach deals with the spectral investigation of PL emission from the front and the rear side of an absorber, whereas the second idea is about the analysis of PL spectra from the front side of the absorber for different absorber thicknesses. Another technique for determination of depth-dependent variations are confocal PL measurements at cross sections of absorbers. The last concept pursues the study of lateral fluctuations with an optical near-field microscope on specially prepared absorbers. These four strategies are demonstrated with samples based on Cu(In,Ga)Se2.","abstract_html":"The aim of this thesis is the development and refinement of photoluminescence (PL) methods for inhomogeneous absorbers to identify lateral fluctuations and depth-dependent variations of spectroscopic, optical and opto-electronic properties in the submicron/micron range. The first approach deals with the spectral investigation of PL emission from the front and the rear side of an absorber, whereas the second idea is about the analysis of PL spectra from the front side of the absorber for different absorber thicknesses. Another technique for determination of depth-dependent variations are confocal PL measurements at cross sections of absorbers. The last concept pursues the study of lateral fluctuations with an optical near-field microscope on specially prepared absorbers. These four strategies are demonstrated with samples based on Cu(In,Ga)Se2.","abstract_has_math":false,"creators":["Neumann, Oliver"],"institution":"Universität Oldenburg","degree_name":null,"degree_level":"phd","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["ARRAY(0x55b969bcb9c0)"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-26T14:02:52Z","subjects":["Physics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://oops.uni-oldenburg.de/1631/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://oops.uni-oldenburg.de/1631/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aoldenburg%3Aoai%3Aoops.uni-oldenburg.de%3A1631","prefix":"oai_dc"},"source_record":{"url":"http://oops.uni-oldenburg.de/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aoops.uni-oldenburg.de%3A1631","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["ARRAY(0x55b969bcb9c0)"]},{"key":"dc:creator","label":"Author","values":["Neumann, Oliver"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Universität Oldenburg"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["phd"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://oops.uni-oldenburg.de/1631/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The aim of this thesis is the development and refinement of photoluminescence (PL) methods for inhomogeneous absorbers to identify lateral fluctuations and depth-dependent variations of spectroscopic, optical and opto-electronic properties in the submicron/micron range. The first approach deals with the spectral investigation of PL emission from the front and the rear side of an absorber, whereas the second idea is about the analysis of PL spectra from the front side of the absorber for different absorber thicknesses. Another technique for determination of depth-dependent variations are confocal PL measurements at cross sections of absorbers. The last concept pursues the study of lateral fluctuations with an optical near-field microscope on specially prepared absorbers. These four strategies are demonstrated with samples based on Cu(In,Ga)Se2."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dc:title","label":"Title","values":["Spectrally and spatially resolved photoluminescence: lateral fluctuations and depth profiles of Cu(In,Ga)Se2-absorbers"]}]}],"canonical_facts":{"dc:contributor.advisor":["ARRAY(0x55b969bcb9c0)"],"dc:creator":["Neumann, Oliver"],"dc:date":["2013"],"dc:date.issued":["2013"],"dc:description.abstract":["The aim of this thesis is the development and refinement of photoluminescence (PL) methods for inhomogeneous absorbers to identify lateral fluctuations and depth-dependent variations of spectroscopic, optical and opto-electronic properties in the submicron/micron range. The first approach deals with the spectral investigation of PL emission from the front and the rear side of an absorber, whereas the second idea is about the analysis of PL spectra from the front side of the absorber for different absorber thicknesses. Another technique for determination of depth-dependent variations are confocal PL measurements at cross sections of absorbers. The last concept pursues the study of lateral fluctuations with an optical near-field microscope on specially prepared absorbers. These four strategies are demonstrated with samples based on Cu(In,Ga)Se2."],"dc:format":["text"],"dc:identifier.uri":["http://oops.uni-oldenburg.de/1631/"],"dc:publisher.institution":["Universität Oldenburg"],"dc:subject":["Physics"],"dc:title":["Spectrally and spatially resolved photoluminescence: lateral fluctuations and depth profiles of Cu(In,Ga)Se2-absorbers"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["phd"]},"updated_at":"2026-11-26T14:02:52Z"}