{"id":{"repo_id":"oldenburg","oai_identifier":"oai:oops.uni-oldenburg.de:2433"},"canonical_url":"https://search.ndltd.org/etd/oldenburg/oai:oops.uni-oldenburg.de:2433","repository":{"repo_id":"oldenburg","name":"Carl von Ossietzky Universität Oldenburg","base_url":"http://oops.uni-oldenburg.de/cgi/oai2"},"display":{"title":"Evaluation of Performance Models against Actual Performance of Grid Connected PV Systems","abstract":"Evaluation of energy performance of grid connected photovoltaic systems is a critical task during project design. In this assessment the common practice is to use modeling software tools that provide an estimated performance of the system and calculate the expected energy yield considering the location and system design specifications. The aim of this research was to understand and evaluate the modeling process in PVsyst v6.25. This study presents a comparison of the real performance of six grid connected PV systems located in Spain, Italy and Chile with their modeled performance using PVsyst. Five systems were fixed structure and one with tracking system. Only systems equipped with crystalline silicon PV modules were evaluated. On an annual basis PVsyst was found to underestimate the energy yield in almost all the studied cases, except in the case of the tracking system. For the system in Chile, the measured data was at high resolution and included the irradiation in the plane-of-array and array temperature allowing a better comparison. In this case, the total relative error between the modeled and measured energy yield in the evaluated period was –0.74%, showing that for this particular system the modeled performance matched the measured output with high accuracy.","abstract_html":"Evaluation of energy performance of grid connected photovoltaic systems is a critical task during project design. In this assessment the common practice is to use modeling software tools that provide an estimated performance of the system and calculate the expected energy yield considering the location and system design specifications. The aim of this research was to understand and evaluate the modeling process in PVsyst v6.25. This study presents a comparison of the real performance of six grid connected PV systems located in Spain, Italy and Chile with their modeled performance using PVsyst. Five systems were fixed structure and one with tracking system. Only systems equipped with crystalline silicon PV modules were evaluated. On an annual basis PVsyst was found to underestimate the energy yield in almost all the studied cases, except in the case of the tracking system. For the system in Chile, the measured data was at high resolution and included the irradiation in the plane-of-array and array temperature allowing a better comparison. In this case, the total relative error between the modeled and measured energy yield in the evaluated period was –0.74%, showing that for this particular system the modeled performance matched the measured output with high accuracy.","abstract_has_math":false,"creators":["Tapia, Mariela"],"institution":"Carl von Ossietzky Universität","degree_name":null,"degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["ARRAY(0x55b969b05618)"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-26T14:02:56Z","subjects":["Physics","Engineering and machine engineering","Electrical engineering, electronics","Civil engineering and environmental protection engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://oops.uni-oldenburg.de/2433/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://oops.uni-oldenburg.de/2433/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aoldenburg%3Aoai%3Aoops.uni-oldenburg.de%3A2433","prefix":"oai_dc"},"source_record":{"url":"http://oops.uni-oldenburg.de/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aoops.uni-oldenburg.de%3A2433","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["ARRAY(0x55b969b05618)"]},{"key":"dc:creator","label":"Author","values":["Tapia, Mariela"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015"]},{"key":"dc:date.issued","label":"Date","values":["2015"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Carl von Ossietzky Universität"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","Engineering and machine engineering","Electrical engineering, electronics","Civil engineering and environmental protection engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://oops.uni-oldenburg.de/2433/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Evaluation of energy performance of grid connected photovoltaic systems is a critical task during project design. In this assessment the common practice is to use modeling software tools that provide an estimated performance of the system and calculate the expected energy yield considering the location and system design specifications. The aim of this research was to understand and evaluate the modeling process in PVsyst v6.25. This study presents a comparison of the real performance of six grid connected PV systems located in Spain, Italy and Chile with their modeled performance using PVsyst. Five systems were fixed structure and one with tracking system. Only systems equipped with crystalline silicon PV modules were evaluated. On an annual basis PVsyst was found to underestimate the energy yield in almost all the studied cases, except in the case of the tracking system. For the system in Chile, the measured data was at high resolution and included the irradiation in the plane-of-array and array temperature allowing a better comparison. In this case, the total relative error between the modeled and measured energy yield in the evaluated period was –0.74%, showing that for this particular system the modeled performance matched the measured output with high accuracy."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dc:title","label":"Title","values":["Evaluation of Performance Models against Actual Performance of Grid Connected PV Systems"]}]}],"canonical_facts":{"dc:contributor.advisor":["ARRAY(0x55b969b05618)"],"dc:creator":["Tapia, Mariela"],"dc:date":["2015"],"dc:date.issued":["2015"],"dc:description.abstract":["Evaluation of energy performance of grid connected photovoltaic systems is a critical task during project design. In this assessment the common practice is to use modeling software tools that provide an estimated performance of the system and calculate the expected energy yield considering the location and system design specifications. The aim of this research was to understand and evaluate the modeling process in PVsyst v6.25. This study presents a comparison of the real performance of six grid connected PV systems located in Spain, Italy and Chile with their modeled performance using PVsyst. Five systems were fixed structure and one with tracking system. Only systems equipped with crystalline silicon PV modules were evaluated. On an annual basis PVsyst was found to underestimate the energy yield in almost all the studied cases, except in the case of the tracking system. For the system in Chile, the measured data was at high resolution and included the irradiation in the plane-of-array and array temperature allowing a better comparison. In this case, the total relative error between the modeled and measured energy yield in the evaluated period was –0.74%, showing that for this particular system the modeled performance matched the measured output with high accuracy."],"dc:format":["text"],"dc:identifier.uri":["http://oops.uni-oldenburg.de/2433/"],"dc:publisher.institution":["Carl von Ossietzky Universität"],"dc:subject":["Physics","Engineering and machine engineering","Electrical engineering, electronics","Civil engineering and environmental protection engineering"],"dc:title":["Evaluation of Performance Models against Actual Performance of Grid Connected PV Systems"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["masters"]},"updated_at":"2026-11-26T14:02:56Z"}