{"id":{"repo_id":"oldenburg","oai_identifier":"oai:oops.uni-oldenburg.de:2859"},"canonical_url":"https://search.ndltd.org/etd/oldenburg/oai:oops.uni-oldenburg.de:2859","repository":{"repo_id":"oldenburg","name":"Carl von Ossietzky Universität Oldenburg","base_url":"http://oops.uni-oldenburg.de/cgi/oai2"},"display":{"title":"Electronic transport and potential barriers at the MoSe2-Mo back contact in Cu(In,Ga)Se2 solar cells","abstract":"In this thesis, the MoSe2-Mo back contact of Cu(In,Ga)Se2 solar cells was investigated and its impact for CIGSe solar cells was assessed. An investigation of a MoSe2/Mo samples, in which Mo layers with varied sodium supply were selenized, revealed, that the sodium mainly diffuses to the sample surface and MoSe2/Mo interface. While an inverse relation between sodium supply and the thickness of the MoSe2 layer was found, the sodium content had hardly an impact on the resistivity of the MoSe2 layers. To investigate the presence of a barrier at the back contact, a study of samples with isolated back contact structures was realized. By the means of IVT measurements, a barrier was found to be present at the CIGSe/MoSe2 interface, while the MoSe2/Mo interface could be classified to be ohmic. Based on all the experimental previous results, a simulation model of the CIGSe solar cell was set up to enable a comprehensive understanding of the impact of the back contact on the solar cell characteristics.","abstract_html":"In this thesis, the MoSe2-Mo back contact of Cu(In,Ga)Se2 solar cells was investigated and its impact for CIGSe solar cells was assessed. An investigation of a MoSe2/Mo samples, in which Mo layers with varied sodium supply were selenized, revealed, that the sodium mainly diffuses to the sample surface and MoSe2/Mo interface. While an inverse relation between sodium supply and the thickness of the MoSe2 layer was found, the sodium content had hardly an impact on the resistivity of the MoSe2 layers. To investigate the presence of a barrier at the back contact, a study of samples with isolated back contact structures was realized. By the means of IVT measurements, a barrier was found to be present at the CIGSe/MoSe2 interface, while the MoSe2/Mo interface could be classified to be ohmic. Based on all the experimental previous results, a simulation model of the CIGSe solar cell was set up to enable a comprehensive understanding of the impact of the back contact on the solar cell characteristics.","abstract_has_math":false,"creators":["Neugebohrn, Nils"],"institution":"Universität Oldenburg","degree_name":null,"degree_level":"phd","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["ARRAY(0x55b969bab400)"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-26T14:02:59Z","subjects":["Physics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://oops.uni-oldenburg.de/2859/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://oops.uni-oldenburg.de/2859/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aoldenburg%3Aoai%3Aoops.uni-oldenburg.de%3A2859","prefix":"oai_dc"},"source_record":{"url":"http://oops.uni-oldenburg.de/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aoops.uni-oldenburg.de%3A2859","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["ARRAY(0x55b969bab400)"]},{"key":"dc:creator","label":"Author","values":["Neugebohrn, Nils"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Universität Oldenburg"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["phd"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://oops.uni-oldenburg.de/2859/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis, the MoSe2-Mo back contact of Cu(In,Ga)Se2 solar cells was investigated and its impact for CIGSe solar cells was assessed. An investigation of a MoSe2/Mo samples, in which Mo layers with varied sodium supply were selenized, revealed, that the sodium mainly diffuses to the sample surface and MoSe2/Mo interface. While an inverse relation between sodium supply and the thickness of the MoSe2 layer was found, the sodium content had hardly an impact on the resistivity of the MoSe2 layers. To investigate the presence of a barrier at the back contact, a study of samples with isolated back contact structures was realized. By the means of IVT measurements, a barrier was found to be present at the CIGSe/MoSe2 interface, while the MoSe2/Mo interface could be classified to be ohmic. Based on all the experimental previous results, a simulation model of the CIGSe solar cell was set up to enable a comprehensive understanding of the impact of the back contact on the solar cell characteristics."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dc:title","label":"Title","values":["Electronic transport and potential barriers at the MoSe2-Mo back contact in Cu(In,Ga)Se2 solar cells"]}]}],"canonical_facts":{"dc:contributor.advisor":["ARRAY(0x55b969bab400)"],"dc:creator":["Neugebohrn, Nils"],"dc:date":["2016"],"dc:date.issued":["2016"],"dc:description.abstract":["In this thesis, the MoSe2-Mo back contact of Cu(In,Ga)Se2 solar cells was investigated and its impact for CIGSe solar cells was assessed. An investigation of a MoSe2/Mo samples, in which Mo layers with varied sodium supply were selenized, revealed, that the sodium mainly diffuses to the sample surface and MoSe2/Mo interface. While an inverse relation between sodium supply and the thickness of the MoSe2 layer was found, the sodium content had hardly an impact on the resistivity of the MoSe2 layers. To investigate the presence of a barrier at the back contact, a study of samples with isolated back contact structures was realized. By the means of IVT measurements, a barrier was found to be present at the CIGSe/MoSe2 interface, while the MoSe2/Mo interface could be classified to be ohmic. Based on all the experimental previous results, a simulation model of the CIGSe solar cell was set up to enable a comprehensive understanding of the impact of the back contact on the solar cell characteristics."],"dc:format":["text"],"dc:identifier.uri":["http://oops.uni-oldenburg.de/2859/"],"dc:publisher.institution":["Universität Oldenburg"],"dc:subject":["Physics"],"dc:title":["Electronic transport and potential barriers at the MoSe2-Mo back contact in Cu(In,Ga)Se2 solar cells"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["phd"]},"updated_at":"2026-11-26T14:02:59Z"}