{"id":{"repo_id":"oldenburg","oai_identifier":"oai:oops.uni-oldenburg.de:3217"},"canonical_url":"https://search.ndltd.org/etd/oldenburg/oai:oops.uni-oldenburg.de:3217","repository":{"repo_id":"oldenburg","name":"Carl von Ossietzky Universität Oldenburg","base_url":"http://oops.uni-oldenburg.de/cgi/oai2"},"display":{"title":"Optimization of spatial balancing and storage needs for large-scale power system integration of fluctuating solar energy","abstract":"Over the past decades, renewable energy sources like solar and wind have gained enormous importance as alternative to the conventional fossil fuel based resources, such as coal, petroleum, and natural gas. These alternative sources are clean, environmental friendly, and naturally replenished. However, these renewable sources are largely weather-dependent and their output is not directly controllable by human beings. As a result, their large scale integration causes grid instability as the traditional power grid is designed for somewhat predictable load and dispatchable generation. In this thesis, this variable nature of renewable sources and their influence on balancing needs are studied for a future European power system with high shares of solar and wind generation. The main focus here is the analysis of the impact of differently inclined and differently oriented PV modules on balancing needs for Europe. Additionally, the model domain is expanded to North Africa to estimate the influence of concentrated solar power import on European storage and backup needs. The results show that the favorable choice of module configuration is very sensitive to the shares of solar and wind. For high solar shares, highly inclined modules with less pronounced annual courses are favorable, if a storage is available with a capacity to cover at least 6 hours of average load. In a wind-dominated scenario, lowly inclined East/West facing modules are most suitable to reduce balancing needs. When no storage is present, a combination of highly inclined East and West facing modules reduces the balancing needs as long as solar share is high enough to distinguish between different configurations. Some of these module configurations may be quite expensive in terms of installed capacity, but repowering old PV modules to configurations best suited for a specific scenario, can be advantageous in the long run.","abstract_html":"Over the past decades, renewable energy sources like solar and wind have gained enormous importance as alternative to the conventional fossil fuel based resources, such as coal, petroleum, and natural gas. These alternative sources are clean, environmental friendly, and naturally replenished. However, these renewable sources are largely weather-dependent and their output is not directly controllable by human beings. As a result, their large scale integration causes grid instability as the traditional power grid is designed for somewhat predictable load and dispatchable generation. In this thesis, this variable nature of renewable sources and their influence on balancing needs are studied for a future European power system with high shares of solar and wind generation. The main focus here is the analysis of the impact of differently inclined and differently oriented PV modules on balancing needs for Europe. Additionally, the model domain is expanded to North Africa to estimate the influence of concentrated solar power import on European storage and backup needs. The results show that the favorable choice of module configuration is very sensitive to the shares of solar and wind. For high solar shares, highly inclined modules with less pronounced annual courses are favorable, if a storage is available with a capacity to cover at least 6 hours of average load. In a wind-dominated scenario, lowly inclined East/West facing modules are most suitable to reduce balancing needs. When no storage is present, a combination of highly inclined East and West facing modules reduces the balancing needs as long as solar share is high enough to distinguish between different configurations. Some of these module configurations may be quite expensive in terms of installed capacity, but repowering old PV modules to configurations best suited for a specific scenario, can be advantageous in the long run.","abstract_has_math":false,"creators":["Chattopadhyay, Kabitri"],"institution":"Universität Oldenburg","degree_name":null,"degree_level":"phd","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["ARRAY(0x55b969b10c78)"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-26T14:03:03Z","subjects":["Physics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://oops.uni-oldenburg.de/3217/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://oops.uni-oldenburg.de/3217/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aoldenburg%3Aoai%3Aoops.uni-oldenburg.de%3A3217","prefix":"oai_dc"},"source_record":{"url":"http://oops.uni-oldenburg.de/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aoops.uni-oldenburg.de%3A3217","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["ARRAY(0x55b969b10c78)"]},{"key":"dc:creator","label":"Author","values":["Chattopadhyay, Kabitri"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Universität Oldenburg"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["phd"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://oops.uni-oldenburg.de/3217/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Over the past decades, renewable energy sources like solar and wind have gained enormous importance as alternative to the conventional fossil fuel based resources, such as coal, petroleum, and natural gas. These alternative sources are clean, environmental friendly, and naturally replenished. However, these renewable sources are largely weather-dependent and their output is not directly controllable by human beings. As a result, their large scale integration causes grid instability as the traditional power grid is designed for somewhat predictable load and dispatchable generation. In this thesis, this variable nature of renewable sources and their influence on balancing needs are studied for a future European power system with high shares of solar and wind generation. The main focus here is the analysis of the impact of differently inclined and differently oriented PV modules on balancing needs for Europe. Additionally, the model domain is expanded to North Africa to estimate the influence of concentrated solar power import on European storage and backup needs. The results show that the favorable choice of module configuration is very sensitive to the shares of solar and wind. For high solar shares, highly inclined modules with less pronounced annual courses are favorable, if a storage is available with a capacity to cover at least 6 hours of average load. In a wind-dominated scenario, lowly inclined East/West facing modules are most suitable to reduce balancing needs. When no storage is present, a combination of highly inclined East and West facing modules reduces the balancing needs as long as solar share is high enough to distinguish between different configurations. Some of these module configurations may be quite expensive in terms of installed capacity, but repowering old PV modules to configurations best suited for a specific scenario, can be advantageous in the long run."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dc:title","label":"Title","values":["Optimization of spatial balancing and storage needs for large-scale power system integration of fluctuating solar energy"]}]}],"canonical_facts":{"dc:contributor.advisor":["ARRAY(0x55b969b10c78)"],"dc:creator":["Chattopadhyay, Kabitri"],"dc:date":["2017"],"dc:date.issued":["2017"],"dc:description.abstract":["Over the past decades, renewable energy sources like solar and wind have gained enormous importance as alternative to the conventional fossil fuel based resources, such as coal, petroleum, and natural gas. These alternative sources are clean, environmental friendly, and naturally replenished. However, these renewable sources are largely weather-dependent and their output is not directly controllable by human beings. As a result, their large scale integration causes grid instability as the traditional power grid is designed for somewhat predictable load and dispatchable generation. In this thesis, this variable nature of renewable sources and their influence on balancing needs are studied for a future European power system with high shares of solar and wind generation. The main focus here is the analysis of the impact of differently inclined and differently oriented PV modules on balancing needs for Europe. Additionally, the model domain is expanded to North Africa to estimate the influence of concentrated solar power import on European storage and backup needs. The results show that the favorable choice of module configuration is very sensitive to the shares of solar and wind. For high solar shares, highly inclined modules with less pronounced annual courses are favorable, if a storage is available with a capacity to cover at least 6 hours of average load. In a wind-dominated scenario, lowly inclined East/West facing modules are most suitable to reduce balancing needs. When no storage is present, a combination of highly inclined East and West facing modules reduces the balancing needs as long as solar share is high enough to distinguish between different configurations. Some of these module configurations may be quite expensive in terms of installed capacity, but repowering old PV modules to configurations best suited for a specific scenario, can be advantageous in the long run."],"dc:format":["text"],"dc:identifier.uri":["http://oops.uni-oldenburg.de/3217/"],"dc:publisher.institution":["Universität Oldenburg"],"dc:subject":["Physics"],"dc:title":["Optimization of spatial balancing and storage needs for large-scale power system integration of fluctuating solar energy"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["phd"]},"updated_at":"2026-11-26T14:03:03Z"}