{"id":{"repo_id":"oldenburg","oai_identifier":"oai:oops.uni-oldenburg.de:3617"},"canonical_url":"https://search.ndltd.org/etd/oldenburg/oai:oops.uni-oldenburg.de:3617","repository":{"repo_id":"oldenburg","name":"Carl von Ossietzky Universität Oldenburg","base_url":"http://oops.uni-oldenburg.de/cgi/oai2"},"display":{"title":"Planing, Simulation and Preparation of a Magnetic Resonant Imaging Experiment based on the Detection of Anisotropic gamma-Radiation from Hyperpolarized Isomers","abstract":"In 2016, the proof of principle for a new method of imaging was presented [1], which uses many elements of traditional Magnetic Resonant Imaging, but replaces the detection of RF induction signals with that of the anisotropic gamma-emission from a hyper-polarized radioactive noble gas. Since gamma-radiation is in comparison very easy to detect, this method is sensitive to concentrations of imaged nuclei that are up to ten orders of magnitudes lower than those needed in conventional MRI. Therefore, it has the perspective of combining the advantages of nuclear tracers, as they are used in SPECT and PET, with the higher spatial resolution of MRI. In addition to presenting a software for numerical simulations of the spin precession and nuclear emission behavior during magnetic resonance experiments on hyper-polarized radioactive xenon, this thesis documents the development of two dedicated setups. The first is dedicated to extracting 131mXe, the radioactive tracer required for the measurements, from commercially available 131I. The second setup is designed for magnetic resonance experiments on hyper-polarized xenon, capable of using both the anisotropic gamma emission from radioactive nuclei as well as induction signals from stable isotopes for detection. It utilizes an existing low-field MRI-scanner and Si-PMT based gamma detectors in combination with elements from a spin-exchange optical pumping setup developed for hyper-polarized MRI on stable Xenon. Both setups were planned, built and tested in the frame of this thesis and are ready for commissioning.","abstract_html":"In 2016, the proof of principle for a new method of imaging was presented [1], which uses many elements of traditional Magnetic Resonant Imaging, but replaces the detection of RF induction signals with that of the anisotropic gamma-emission from a hyper-polarized radioactive noble gas. Since gamma-radiation is in comparison very easy to detect, this method is sensitive to concentrations of imaged nuclei that are up to ten orders of magnitudes lower than those needed in conventional MRI. Therefore, it has the perspective of combining the advantages of nuclear tracers, as they are used in SPECT and PET, with the higher spatial resolution of MRI. In addition to presenting a software for numerical simulations of the spin precession and nuclear emission behavior during magnetic resonance experiments on hyper-polarized radioactive xenon, this thesis documents the development of two dedicated setups. The first is dedicated to extracting 131mXe, the radioactive tracer required for the measurements, from commercially available 131I. The second setup is designed for magnetic resonance experiments on hyper-polarized xenon, capable of using both the anisotropic gamma emission from radioactive nuclei as well as induction signals from stable isotopes for detection. It utilizes an existing low-field MRI-scanner and Si-PMT based gamma detectors in combination with elements from a spin-exchange optical pumping setup developed for hyper-polarized MRI on stable Xenon. Both setups were planned, built and tested in the frame of this thesis and are ready for commissioning.","abstract_has_math":false,"creators":["Engel, Robin"],"institution":"Universität Oldenburg","degree_name":null,"degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["ARRAY(0x55b969b15838)"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-07","date_published":"2018-07","updated_at":"2026-11-26T14:03:03Z","subjects":["Physics","Medicine and health"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://oops.uni-oldenburg.de/3617/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://oops.uni-oldenburg.de/3617/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aoldenburg%3Aoai%3Aoops.uni-oldenburg.de%3A3617","prefix":"oai_dc"},"source_record":{"url":"http://oops.uni-oldenburg.de/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aoops.uni-oldenburg.de%3A3617","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["ARRAY(0x55b969b15838)"]},{"key":"dc:creator","label":"Author","values":["Engel, Robin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-07-01"]},{"key":"dc:date.issued","label":"Date","values":["2018-07"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Universität Oldenburg"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] Yuan Zheng, G Wilson Miller, William A Tobias, and Gordon D Cates. A method for imaging and spectroscopy using γ-rays and magnetic resonance. Nature, 537(7622):652, 2016. [2] H. Postma N.J. Stone. Low-Temperature Nuclear Orientation. North-Holland Physics Publishing, 1986. ISBN 0-444-86994-8. [3] Olaf D¨ossel. Bildgebende Verfahren in der Medizin, Von der Technik zur Medi zinischen Anwendung. Springer Vieweg, 2 edition, 2016. ISBN 978-3-642-54406- 4. [4] Richard B. Firestone. Table of isotopes. cd rom edition. 1996. Version 1.0. [5] Penelope Bouziotis and Carlo Fiorini. Spect/mri: dreams or reality? Clinical and Translational Imaging, 2(6):571{573, 2014. [6] M Kowalska, P Aschenbrenner, M Baranowski, Mark L Bissell, W Gins, RD Harding, H Heylen, G Neyens, Stavroula Pallada, N Severijns, et al. New laser polarization line at the isolde facility. Journal of Physics G: Nuclear and Particle Physics, 44(8):084005, 2017. [7] HA Tolhoek and JAM Cox. Angular distribution and polarization of gamma radiation emitted by oriented nuclei. Physica, 19(1-12):101{119, 1953. [8] Grace MA Blin-Stoyle RJ. Oriented nuclei. In S Fl¨ugge, editor, Encycopedia of Physics XLII: Nuclear Reactions III, volume 42, page 555. Springer Verlag, 1957. [9] Jack K. Becconsall Horst Friebolin. Basic One- and Two-Dimensional NMR Spectroscopy. WILEY-VCH, 3 edition, 1998. ISBN 3-527-29513-5. [10] Jean-No¨el Hyacinthe. D´eveloppements m´ethodologiques en RMN du 129Xe hy perpolaris´e en vue d’applications `a la mesure de la perfusion c´er´ebrale chez le petit animal. PhD thesis, Universit´e Joseph Fourier (Grenoble), 2004. [11] W Happer, E Miron, S Schaefer, D Schreiber, WA Van Wijngaarden, and X Zeng. Polarization of the nuclear spins of noble-gas atoms by spin exchange with optically pumped alkali-metal atoms. Physical Review A, 29(6):3092, 1984. [12] Thomas Meersmann and Eike Brunner. Hyperpolarized xenon-129 magnetic resonance: concepts, production, techniques and applications. Number 4. Royal Society of Chemistry, 2015. [13] Yuan Zheng. Low Field MRI and the Development of Polarized Nuclear Imaging (PNI) - A New Imaging Modality. PhD thesis, University of Virginia, 9 2014. [14] Daniel A Steck. Rubidium 87 d line data, 2001. [15] Joseph S Six, Theodore Hughes-Riley, Karl F Stupic, Galina E Pavlovskaya, and Thomas Meersmann. Pathway to cryogen free production of hyperpolarized krypton-83 and xenon-129. PLoS One, 7(11):e49927, 2012. [16] T Yamazaki. Tables of coefficients for angular distribution of gamma rays from aligned nuclei (nuclear data sheets, section a). Nucl. Data, Sect. A, 3: No. 1, 1-24 (Aug. 1967)., 3(UCRL{17086), 1967. [17] James M Bright, Trenton T Rees, Louis E Baca, and Richard L Green. Volatil ity of radiopharmacy-prepared sodium iodide-131 capsules. Journal of nuclear medicine technology, 28(1):52{55, 2000. [18] Ellsworth J Browning, Krishnadas Banerjee, and William E Reisinger Jr. Air borne concentration of i-131 in a nuclear medicine laboratory. Journal of nuclear medicine: official publication, Society of Nuclear Medicine, 19(9):1078{1081, 1978. [19] Pin Jern Ker, John PR David, and Chee Hing Tan. Temperature dependence of gain and excess noise in inas electron avalanche photodiodes. Optics express, 20(28):29568{29576, 2012. [20] Y Kamisho, M Mihara, K Matsuta, M Fukuda, M Yaguchi, M Wakabayashi, Y Morita, J Ohno, S Shinozaki, R Kambe, et al. Development of the pulse nmr method utilizing the short-lived β-emitter 12b. Hyperfine Interactions, 222 (1-3):121{125, 2013. [21] R Engel. Preparation of transversal relaxation time measurements using beta nmr at the vito beamline. Technical report, ISOLDE, CERN, 2018. [22] M Kowalska. Collection of 133mxe for mri+spect feasibility study. Technical Report CERN-INTC-2017-092, CERN, 2017."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","Medicine and health"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://oops.uni-oldenburg.de/3617/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In 2016, the proof of principle for a new method of imaging was presented [1], which uses many elements of traditional Magnetic Resonant Imaging, but replaces the detection of RF induction signals with that of the anisotropic gamma-emission from a hyper-polarized radioactive noble gas. Since gamma-radiation is in comparison very easy to detect, this method is sensitive to concentrations of imaged nuclei that are up to ten orders of magnitudes lower than those needed in conventional MRI. Therefore, it has the perspective of combining the advantages of nuclear tracers, as they are used in SPECT and PET, with the higher spatial resolution of MRI. In addition to presenting a software for numerical simulations of the spin precession and nuclear emission behavior during magnetic resonance experiments on hyper-polarized radioactive xenon, this thesis documents the development of two dedicated setups. The first is dedicated to extracting 131mXe, the radioactive tracer required for the measurements, from commercially available 131I. The second setup is designed for magnetic resonance experiments on hyper-polarized xenon, capable of using both the anisotropic gamma emission from radioactive nuclei as well as induction signals from stable isotopes for detection. It utilizes an existing low-field MRI-scanner and Si-PMT based gamma detectors in combination with elements from a spin-exchange optical pumping setup developed for hyper-polarized MRI on stable Xenon. Both setups were planned, built and tested in the frame of this thesis and are ready for commissioning."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dc:title","label":"Title","values":["Planing, Simulation and Preparation of a Magnetic Resonant Imaging Experiment based on the Detection of Anisotropic gamma-Radiation from Hyperpolarized Isomers"]}]}],"canonical_facts":{"dc:contributor.advisor":["ARRAY(0x55b969b15838)"],"dc:creator":["Engel, Robin"],"dc:date":["2018-07-01"],"dc:date.issued":["2018-07"],"dc:description.abstract":["In 2016, the proof of principle for a new method of imaging was presented [1], which uses many elements of traditional Magnetic Resonant Imaging, but replaces the detection of RF induction signals with that of the anisotropic gamma-emission from a hyper-polarized radioactive noble gas. Since gamma-radiation is in comparison very easy to detect, this method is sensitive to concentrations of imaged nuclei that are up to ten orders of magnitudes lower than those needed in conventional MRI. Therefore, it has the perspective of combining the advantages of nuclear tracers, as they are used in SPECT and PET, with the higher spatial resolution of MRI. In addition to presenting a software for numerical simulations of the spin precession and nuclear emission behavior during magnetic resonance experiments on hyper-polarized radioactive xenon, this thesis documents the development of two dedicated setups. The first is dedicated to extracting 131mXe, the radioactive tracer required for the measurements, from commercially available 131I. The second setup is designed for magnetic resonance experiments on hyper-polarized xenon, capable of using both the anisotropic gamma emission from radioactive nuclei as well as induction signals from stable isotopes for detection. It utilizes an existing low-field MRI-scanner and Si-PMT based gamma detectors in combination with elements from a spin-exchange optical pumping setup developed for hyper-polarized MRI on stable Xenon. Both setups were planned, built and tested in the frame of this thesis and are ready for commissioning."],"dc:format":["text"],"dc:identifier.uri":["http://oops.uni-oldenburg.de/3617/"],"dc:publisher.institution":["Universität Oldenburg"],"dc:relation.references":["[1] Yuan Zheng, G Wilson Miller, William A Tobias, and Gordon D Cates. A method for imaging and spectroscopy using γ-rays and magnetic resonance. Nature, 537(7622):652, 2016. [2] H. Postma N.J. Stone. Low-Temperature Nuclear Orientation. North-Holland Physics Publishing, 1986. ISBN 0-444-86994-8. [3] Olaf D¨ossel. Bildgebende Verfahren in der Medizin, Von der Technik zur Medi zinischen Anwendung. Springer Vieweg, 2 edition, 2016. ISBN 978-3-642-54406- 4. [4] Richard B. Firestone. Table of isotopes. cd rom edition. 1996. Version 1.0. [5] Penelope Bouziotis and Carlo Fiorini. Spect/mri: dreams or reality? Clinical and Translational Imaging, 2(6):571{573, 2014. [6] M Kowalska, P Aschenbrenner, M Baranowski, Mark L Bissell, W Gins, RD Harding, H Heylen, G Neyens, Stavroula Pallada, N Severijns, et al. New laser polarization line at the isolde facility. Journal of Physics G: Nuclear and Particle Physics, 44(8):084005, 2017. [7] HA Tolhoek and JAM Cox. Angular distribution and polarization of gamma radiation emitted by oriented nuclei. Physica, 19(1-12):101{119, 1953. [8] Grace MA Blin-Stoyle RJ. Oriented nuclei. In S Fl¨ugge, editor, Encycopedia of Physics XLII: Nuclear Reactions III, volume 42, page 555. Springer Verlag, 1957. [9] Jack K. Becconsall Horst Friebolin. Basic One- and Two-Dimensional NMR Spectroscopy. WILEY-VCH, 3 edition, 1998. ISBN 3-527-29513-5. [10] Jean-No¨el Hyacinthe. D´eveloppements m´ethodologiques en RMN du 129Xe hy perpolaris´e en vue d’applications `a la mesure de la perfusion c´er´ebrale chez le petit animal. PhD thesis, Universit´e Joseph Fourier (Grenoble), 2004. [11] W Happer, E Miron, S Schaefer, D Schreiber, WA Van Wijngaarden, and X Zeng. Polarization of the nuclear spins of noble-gas atoms by spin exchange with optically pumped alkali-metal atoms. Physical Review A, 29(6):3092, 1984. [12] Thomas Meersmann and Eike Brunner. Hyperpolarized xenon-129 magnetic resonance: concepts, production, techniques and applications. Number 4. Royal Society of Chemistry, 2015. [13] Yuan Zheng. Low Field MRI and the Development of Polarized Nuclear Imaging (PNI) - A New Imaging Modality. PhD thesis, University of Virginia, 9 2014. [14] Daniel A Steck. Rubidium 87 d line data, 2001. [15] Joseph S Six, Theodore Hughes-Riley, Karl F Stupic, Galina E Pavlovskaya, and Thomas Meersmann. Pathway to cryogen free production of hyperpolarized krypton-83 and xenon-129. PLoS One, 7(11):e49927, 2012. [16] T Yamazaki. Tables of coefficients for angular distribution of gamma rays from aligned nuclei (nuclear data sheets, section a). Nucl. Data, Sect. A, 3: No. 1, 1-24 (Aug. 1967)., 3(UCRL{17086), 1967. [17] James M Bright, Trenton T Rees, Louis E Baca, and Richard L Green. Volatil ity of radiopharmacy-prepared sodium iodide-131 capsules. Journal of nuclear medicine technology, 28(1):52{55, 2000. [18] Ellsworth J Browning, Krishnadas Banerjee, and William E Reisinger Jr. Air borne concentration of i-131 in a nuclear medicine laboratory. Journal of nuclear medicine: official publication, Society of Nuclear Medicine, 19(9):1078{1081, 1978. [19] Pin Jern Ker, John PR David, and Chee Hing Tan. Temperature dependence of gain and excess noise in inas electron avalanche photodiodes. Optics express, 20(28):29568{29576, 2012. [20] Y Kamisho, M Mihara, K Matsuta, M Fukuda, M Yaguchi, M Wakabayashi, Y Morita, J Ohno, S Shinozaki, R Kambe, et al. Development of the pulse nmr method utilizing the short-lived β-emitter 12b. Hyperfine Interactions, 222 (1-3):121{125, 2013. [21] R Engel. Preparation of transversal relaxation time measurements using beta nmr at the vito beamline. Technical report, ISOLDE, CERN, 2018. [22] M Kowalska. Collection of 133mxe for mri+spect feasibility study. Technical Report CERN-INTC-2017-092, CERN, 2017."],"dc:subject":["Physics","Medicine and health"],"dc:title":["Planing, Simulation and Preparation of a Magnetic Resonant Imaging Experiment based on the Detection of Anisotropic gamma-Radiation from Hyperpolarized Isomers"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["masters"]},"updated_at":"2026-11-26T14:03:03Z"}