{"id":{"repo_id":"pohang","oai_identifier":"oai:oasis.postech.ac.kr:2014.oak/1401"},"canonical_url":"https://search.ndltd.org/etd/pohang/oai:oasis.postech.ac.kr:2014.oak/1401","repository":{"repo_id":"pohang","name":"Pohang University of Science and Technology","base_url":"http://oasis.postech.ac.kr/oai/request"},"display":{"title":"Electrocapillary driven Flow at the Polar, Non-polar Interface","abstract":"Marangoni flow is occurred in the vicinity of the interface. It takes place due to the interfacial tension gradient. This is usually caused by two factors, temperature, and concentration gradient. Not only these two factors, but also one factor that makes interfacial tension gradient exists. That factor is the electrocapillarity.Electrocapillarity is the change in interfacial tension due to an electric potential gradient in the presence of a surface charge. Principle of this phenomenon is similar to thermal-marangoni and solutal-marangoni flows. This electrocapillarity is easily applied to the certain system because electric potential can be intentionally made. Because of this advantage, electrocapillarity can be utilized to control the flow at the interface.In order to verify this electrocapillary flow, experiments of aqueous solution/MIBK and Ga-In/Aqueous system were conducted in room temperature. After results had been obtained, two types of modeling were conducted","abstract_html":"Marangoni flow is occurred in the vicinity of the interface. It takes place due to the interfacial tension gradient. This is usually caused by two factors, temperature, and concentration gradient. Not only these two factors, but also one factor that makes interfacial tension gradient exists. That factor is the electrocapillarity.Electrocapillarity is the change in interfacial tension due to an electric potential gradient in the presence of a surface charge. Principle of this phenomenon is similar to thermal-marangoni and solutal-marangoni flows. This electrocapillarity is easily applied to the certain system because electric potential can be intentionally made. Because of this advantage, electrocapillarity can be utilized to control the flow at the interface.In order to verify this electrocapillary flow, experiments of aqueous solution/MIBK and Ga-In/Aqueous system were conducted in room temperature. After results had been obtained, two types of modeling were conducted","abstract_has_math":false,"creators":["유재헌"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-26T04:05:26Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:2014.oak/1401"],"render_values":[{"text":"hdl:2014.oak/1401","href":null,"code":true}]},{"key":"mods:identifier.other","label":"Mods Identifier Other","values":["OAK-2014-00899"],"render_values":[{"text":"OAK-2014-00899","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001216852","outbound_label":"Repository record","outbound_source":"mods:identifier.uri","record_url":"http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001216852","record_label":"Repository record","record_kind":"record","record_source":"mods:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Apohang%3Aoai%3Aoasis.postech.ac.kr%3A2014.oak%2F1401","prefix":"oai_dc"},"source_record":{"url":"http://oasis.postech.ac.kr/oai/request?verb=GetRecord&metadataPrefix=mets&identifier=oai%3Aoasis.postech.ac.kr%3A2014.oak%2F1401","prefix":"mets"},"metadata_groups":[{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:2014.oak/1401"]},{"key":"mods:identifier.other","label":"Mods Identifier Other","values":["OAK-2014-00899"]},{"key":"mods:identifier.uri","label":"Mods Identifier URI","values":["http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001216852"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.other","label":"Dc Description Other","values":["Marangoni flow is occurred in the vicinity of the interface. It takes place due to the interfacial tension gradient. This is usually caused by two factors, temperature, and concentration gradient. Not only these two factors, but also one factor that makes interfacial tension gradient exists. That factor is the electrocapillarity.Electrocapillarity is the change in interfacial tension due to an electric potential gradient in the presence of a surface charge. Principle of this phenomenon is similar to thermal-marangoni and solutal-marangoni flows. This electrocapillarity is easily applied to the certain system because electric potential can be intentionally made. Because of this advantage, electrocapillarity can be utilized to control the flow at the interface.In order to verify this electrocapillary flow, experiments of aqueous solution/MIBK and Ga-In/Aqueous system were conducted in room temperature. After results had been obtained, two types of modeling were conducted"]},{"key":"dc:title","label":"Title","values":["Electrocapillary driven Flow at the Polar, Non-polar Interface"]},{"key":"mods:accesscondition.useandreproduction","label":"Mods Accesscondition Useandreproduction","values":["BY_NC_ND"]},{"key":"mods:dateaccessioned","label":"Mods Dateaccessioned","values":["2014-12-01T11:47:51Z"]},{"key":"mods:dateavailable","label":"Mods Dateavailable","values":["2014-12-01T11:47:51Z"]},{"key":"mods:namepart","label":"Mods Namepart","values":["유재헌","철강대학원 철강학과"]},{"key":"mods:roleterm.text","label":"Mods Roleterm Text","values":["author","college"]}]}],"canonical_facts":{"dc:date.issued":["2012"],"dc:description.other":["Marangoni flow is occurred in the vicinity of the interface. It takes place due to the interfacial tension gradient. This is usually caused by two factors, temperature, and concentration gradient. Not only these two factors, but also one factor that makes interfacial tension gradient exists. That factor is the electrocapillarity.Electrocapillarity is the change in interfacial tension due to an electric potential gradient in the presence of a surface charge. Principle of this phenomenon is similar to thermal-marangoni and solutal-marangoni flows. This electrocapillarity is easily applied to the certain system because electric potential can be intentionally made. Because of this advantage, electrocapillarity can be utilized to control the flow at the interface.In order to verify this electrocapillary flow, experiments of aqueous solution/MIBK and Ga-In/Aqueous system were conducted in room temperature. After results had been obtained, two types of modeling were conducted"],"dc:identifier":["hdl:2014.oak/1401"],"dc:title":["Electrocapillary driven Flow at the Polar, Non-polar Interface"],"dc:type":["Thesis"],"mods:accesscondition.useandreproduction":["BY_NC_ND"],"mods:dateaccessioned":["2014-12-01T11:47:51Z"],"mods:dateavailable":["2014-12-01T11:47:51Z"],"mods:identifier.other":["OAK-2014-00899"],"mods:identifier.uri":["http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001216852"],"mods:namepart":["유재헌","철강대학원 철강학과"],"mods:roleterm.text":["author","college"]},"updated_at":"2026-11-26T04:05:26Z"}