{"id":{"repo_id":"pohang","oai_identifier":"oai:oasis.postech.ac.kr:2014.oak/1467"},"canonical_url":"https://search.ndltd.org/etd/pohang/oai:oasis.postech.ac.kr:2014.oak/1467","repository":{"repo_id":"pohang","name":"Pohang University of Science and Technology","base_url":"http://oasis.postech.ac.kr/oai/request"},"display":{"title":"풍력발전용 2MW급 방사 자속형 영구자석 동기발전기와 축방향 자속형 영구자석 동기발전기 설계 및 비교","abstract":"Most of the permanent magnet generator type for wind turbine as MW-class applications is RFPM(Radial Flux Permanent Magnet) type. In this study, it is concluded that MW-class AFPM(Axial Flux Permanent Magnet) type generator has its own characteristics which are compactness in volume, cost reduction especially in magnet portion, and lower efficiency than RFPM type. To compare AFPM with RFPM, a 2MW Hyundai Rotem Direct-drive RFPM type generator is redesigned as a 2MW AFPM machine. A newly designed 2MW AFPM machine has the shape of double-sided stator and single rotor which is called AFIPM(Axial Flux Interior Permanent Magnet) topology. FEM[Ansys] simulation is conducted based on Quasi-3D method to perform electromagnetic and thermal analysis.","abstract_html":"Most of the permanent magnet generator type for wind turbine as MW-class applications is RFPM(Radial Flux Permanent Magnet) type. In this study, it is concluded that MW-class AFPM(Axial Flux Permanent Magnet) type generator has its own characteristics which are compactness in volume, cost reduction especially in magnet portion, and lower efficiency than RFPM type. To compare AFPM with RFPM, a 2MW Hyundai Rotem Direct-drive RFPM type generator is redesigned as a 2MW AFPM machine. A newly designed 2MW AFPM machine has the shape of double-sided stator and single rotor which is called AFIPM(Axial Flux Interior Permanent Magnet) topology. FEM[Ansys] simulation is conducted based on Quasi-3D method to perform electromagnetic and thermal analysis.","abstract_has_math":false,"creators":["이수호"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-26T04:05:28Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:2014.oak/1467"],"render_values":[{"text":"hdl:2014.oak/1467","href":null,"code":true}]},{"key":"mods:identifier.other","label":"Mods Identifier Other","values":["OAK-2014-00965"],"render_values":[{"text":"OAK-2014-00965","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001218283","outbound_label":"Repository record","outbound_source":"mods:identifier.uri","record_url":"http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001218283","record_label":"Repository record","record_kind":"record","record_source":"mods:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Apohang%3Aoai%3Aoasis.postech.ac.kr%3A2014.oak%2F1467","prefix":"oai_dc"},"source_record":{"url":"http://oasis.postech.ac.kr/oai/request?verb=GetRecord&metadataPrefix=mets&identifier=oai%3Aoasis.postech.ac.kr%3A2014.oak%2F1467","prefix":"mets"},"metadata_groups":[{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:2014.oak/1467"]},{"key":"mods:identifier.other","label":"Mods Identifier Other","values":["OAK-2014-00965"]},{"key":"mods:identifier.uri","label":"Mods Identifier URI","values":["http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001218283"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.other","label":"Dc Description Other","values":["Most of the permanent magnet generator type for wind turbine as MW-class applications is RFPM(Radial Flux Permanent Magnet) type. In this study, it is concluded that MW-class AFPM(Axial Flux Permanent Magnet) type generator has its own characteristics which are compactness in volume, cost reduction especially in magnet portion, and lower efficiency than RFPM type. To compare AFPM with RFPM, a 2MW Hyundai Rotem Direct-drive RFPM type generator is redesigned as a 2MW AFPM machine. A newly designed 2MW AFPM machine has the shape of double-sided stator and single rotor which is called AFIPM(Axial Flux Interior Permanent Magnet) topology. FEM[Ansys] simulation is conducted based on Quasi-3D method to perform electromagnetic and thermal analysis."]},{"key":"dc:title","label":"Title","values":["풍력발전용 2MW급 방사 자속형 영구자석 동기발전기와 축방향 자속형 영구자석 동기발전기 설계 및 비교"]},{"key":"mods:accesscondition.useandreproduction","label":"Mods Accesscondition Useandreproduction","values":["BY_NC_ND"]},{"key":"mods:dateaccessioned","label":"Mods Dateaccessioned","values":["2014-12-01T11:47:57Z"]},{"key":"mods:dateavailable","label":"Mods Dateavailable","values":["2014-12-01T11:47:57Z"]},{"key":"mods:namepart","label":"Mods Namepart","values":["이수호","일반대학원 풍력특성화과정"]},{"key":"mods:roleterm.text","label":"Mods Roleterm Text","values":["author","college"]}]}],"canonical_facts":{"dc:date.issued":["2012"],"dc:description.other":["Most of the permanent magnet generator type for wind turbine as MW-class applications is RFPM(Radial Flux Permanent Magnet) type. In this study, it is concluded that MW-class AFPM(Axial Flux Permanent Magnet) type generator has its own characteristics which are compactness in volume, cost reduction especially in magnet portion, and lower efficiency than RFPM type. To compare AFPM with RFPM, a 2MW Hyundai Rotem Direct-drive RFPM type generator is redesigned as a 2MW AFPM machine. A newly designed 2MW AFPM machine has the shape of double-sided stator and single rotor which is called AFIPM(Axial Flux Interior Permanent Magnet) topology. FEM[Ansys] simulation is conducted based on Quasi-3D method to perform electromagnetic and thermal analysis."],"dc:identifier":["hdl:2014.oak/1467"],"dc:title":["풍력발전용 2MW급 방사 자속형 영구자석 동기발전기와 축방향 자속형 영구자석 동기발전기 설계 및 비교"],"dc:type":["Thesis"],"mods:accesscondition.useandreproduction":["BY_NC_ND"],"mods:dateaccessioned":["2014-12-01T11:47:57Z"],"mods:dateavailable":["2014-12-01T11:47:57Z"],"mods:identifier.other":["OAK-2014-00965"],"mods:identifier.uri":["http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001218283"],"mods:namepart":["이수호","일반대학원 풍력특성화과정"],"mods:roleterm.text":["author","college"]},"updated_at":"2026-11-26T04:05:28Z"}