{"id":{"repo_id":"pohang","oai_identifier":"oai:oasis.postech.ac.kr:2014.oak/1538"},"canonical_url":"https://search.ndltd.org/etd/pohang/oai:oasis.postech.ac.kr:2014.oak/1538","repository":{"repo_id":"pohang","name":"Pohang University of Science and Technology","base_url":"http://oasis.postech.ac.kr/oai/request"},"display":{"title":"초음파 영상 장치를 위한 8채널 아날로그 빔포머 회로","abstract":"This research presents an 8-channel analog beamformer circuit. We used an analog beamformer to sum the ultrasound waves from the focal point. The implemented analog beamformer consists of sub-analog beamformer, switch clock generator, and multiplexer. Each sub-analog beamformer is dedicated to a single focal point. After the add operation, the sub-analog beamformer is allocated to another focal point in a time-interleaving manner. To efficiently store large amounts of delay profile information, coded clocks were employed for each channel. The switch clock generator was implemented using Verilog. Through this research a beamformer circuit was implemented using small hardware, which has future applications in in portable ultrasound machines and many-channel beamforming systems.","abstract_html":"This research presents an 8-channel analog beamformer circuit. We used an analog beamformer to sum the ultrasound waves from the focal point. The implemented analog beamformer consists of sub-analog beamformer, switch clock generator, and multiplexer. Each sub-analog beamformer is dedicated to a single focal point. After the add operation, the sub-analog beamformer is allocated to another focal point in a time-interleaving manner. To efficiently store large amounts of delay profile information, coded clocks were employed for each channel. The switch clock generator was implemented using Verilog. Through this research a beamformer circuit was implemented using small hardware, which has future applications in in portable ultrasound machines and many-channel beamforming systems.","abstract_has_math":false,"creators":["송은우"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-26T04:05:31Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:2014.oak/1538"],"render_values":[{"text":"hdl:2014.oak/1538","href":null,"code":true}]},{"key":"mods:identifier.other","label":"Mods Identifier Other","values":["OAK-2014-01036"],"render_values":[{"text":"OAK-2014-01036","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001221415","outbound_label":"Repository record","outbound_source":"mods:identifier.uri","record_url":"http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001221415","record_label":"Repository record","record_kind":"record","record_source":"mods:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Apohang%3Aoai%3Aoasis.postech.ac.kr%3A2014.oak%2F1538","prefix":"oai_dc"},"source_record":{"url":"http://oasis.postech.ac.kr/oai/request?verb=GetRecord&metadataPrefix=mets&identifier=oai%3Aoasis.postech.ac.kr%3A2014.oak%2F1538","prefix":"mets"},"metadata_groups":[{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:2014.oak/1538"]},{"key":"mods:identifier.other","label":"Mods Identifier Other","values":["OAK-2014-01036"]},{"key":"mods:identifier.uri","label":"Mods Identifier URI","values":["http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001221415"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.other","label":"Dc Description Other","values":["This research presents an 8-channel analog beamformer circuit. We used an analog beamformer to sum the ultrasound waves from the focal point. The implemented analog beamformer consists of sub-analog beamformer, switch clock generator, and multiplexer. Each sub-analog beamformer is dedicated to a single focal point. After the add operation, the sub-analog beamformer is allocated to another focal point in a time-interleaving manner. To efficiently store large amounts of delay profile information, coded clocks were employed for each channel. The switch clock generator was implemented using Verilog. Through this research a beamformer circuit was implemented using small hardware, which has future applications in in portable ultrasound machines and many-channel beamforming systems."]},{"key":"dc:title","label":"Title","values":["초음파 영상 장치를 위한 8채널 아날로그 빔포머 회로"]},{"key":"mods:accesscondition.useandreproduction","label":"Mods Accesscondition Useandreproduction","values":["BY_NC_ND"]},{"key":"mods:dateaccessioned","label":"Mods Dateaccessioned","values":["2014-12-01T11:48:06Z"]},{"key":"mods:dateavailable","label":"Mods Dateavailable","values":["2014-12-01T11:48:06Z"]},{"key":"mods:namepart","label":"Mods Namepart","values":["송은우","일반대학원 전자전기공학과"]},{"key":"mods:roleterm.text","label":"Mods Roleterm Text","values":["author","college"]}]}],"canonical_facts":{"dc:date.issued":["2012"],"dc:description.other":["This research presents an 8-channel analog beamformer circuit. We used an analog beamformer to sum the ultrasound waves from the focal point. The implemented analog beamformer consists of sub-analog beamformer, switch clock generator, and multiplexer. Each sub-analog beamformer is dedicated to a single focal point. After the add operation, the sub-analog beamformer is allocated to another focal point in a time-interleaving manner. To efficiently store large amounts of delay profile information, coded clocks were employed for each channel. The switch clock generator was implemented using Verilog. Through this research a beamformer circuit was implemented using small hardware, which has future applications in in portable ultrasound machines and many-channel beamforming systems."],"dc:identifier":["hdl:2014.oak/1538"],"dc:title":["초음파 영상 장치를 위한 8채널 아날로그 빔포머 회로"],"dc:type":["Thesis"],"mods:accesscondition.useandreproduction":["BY_NC_ND"],"mods:dateaccessioned":["2014-12-01T11:48:06Z"],"mods:dateavailable":["2014-12-01T11:48:06Z"],"mods:identifier.other":["OAK-2014-01036"],"mods:identifier.uri":["http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001221415"],"mods:namepart":["송은우","일반대학원 전자전기공학과"],"mods:roleterm.text":["author","college"]},"updated_at":"2026-11-26T04:05:31Z"}