{"id":{"repo_id":"pohang","oai_identifier":"oai:oasis.postech.ac.kr:2014.oak/1958"},"canonical_url":"https://search.ndltd.org/etd/pohang/oai:oasis.postech.ac.kr:2014.oak/1958","repository":{"repo_id":"pohang","name":"Pohang University of Science and Technology","base_url":"http://oasis.postech.ac.kr/oai/request"},"display":{"title":"Single PMMA/PPy composite microtubes as chemical sensors","abstract":"Fabrication of polymeric micro/nanotubes is receiving increasing attention because of their potential applications in microfluidic, catalysis, tissue engineering, drug delivery, photonics, sensing, and so on. Main ingredients of polymeric micro/nanotube structures, however, have been mostly limited to single component polymers. Polymer composite that has broad applications as one-dimensional (1-D) fibers, wires, or cables by its enhanced mechanical property and thermochemical stability is largely unexplored as a form of hollow microtube structure.Integration of micro/nanotubes with various electrical, chemical or biological properties has been more and more important in bio- or chemical sensors. Here, one of the issues is to regulate the scales of tubes (diameters and wall thicknesses) as well as their positions. Conventional fabrication methods, such as self-assembly, templating, electrospinning, co-electrospinning, wetting, TUFT(tube by fiber template) process, self rolling, co-extrusion method, direct laser polymerization, and solvent evaporation induced phase separation, are not suitable for such regulation. For polymer composite microtubes, it is furthermore a challenge to well regulate their scales, even if successfully fabricated.In this study, single PMMA/PPy composite microtubes are realized by a meniscus-guided approach conjugated with the “coffee-ring effect” in a microscale meniscus of a colloidal solution. Furthermore, this thesis provides that individual addressable PMMA/PPy composite microtubes as stretchable chemical sensors.The first part of the thesis is the development of direct writing of single freestanding hollow microtubes of a polymer composite (poly(methyl methacrylate)/polypyrrole (PMMA/PPy)). In fact, single freestanding PMMA/PPy microtubes were fabricated by a meniscus-guided approach, based on the “coffee-ring effect” in an evaporating microscale meniscus of a colloidal solution. This method permitted to regulate the outer diameter and wall thickness of the PMMA/PPy microtubes simply by controlling the meniscus-guiding and the coffee-ring effect. Furthermore, an array of freestanding microtubes, individually controlled in scale and in position was realized.The second topic is to develop individually addressable PMMA/PPy composite microtubes as chemical sensors based on direct-writing of the composite microtubes. In fact, the composite microtubes showed a good potential as chemical sensors by demonstrating gas-concentration-driven modulation of electrical resistance for various gases such as NH3 and Volatile Organic Compounds (i.e. methanol, ethanol). The composite microtubes exhibited a higher sensitivity than those of PMMA/PPy composite microwires, much higher than those of PPy microwires at room temperature. Remarkably, strong robustness against humidity (20 to 80%) was demonstrated in the composite microtubes, due to the water-insensitivity of PMMA layer.The last topic of the thesis is to develop stretchable chemical sensor based on the PMMA/PPy composite microtubes. By writing the composite microtube into a stretchable 3-D architecture, specifically a 3-D arch shape, a very high stretchability up to ~ 110% was achieved with little change in the electrical conductance. Notably, the composite microtubes were robust against a stretching cycle up to 2 x 104. Furthermore, chemical sensitivity of the composite microtubes was not affected by stretching up to 80% for various NH3 concentrations (1 to 1000 ppm).From this work, one may challenge to research for a number of other composite materials and more complicated structures, based on the regulation of the meniscus geometry-dependent coffee-ring effect. Furthermore, individually addressable conductive polymer composite microtubes with a stretchable 3-D architecture could have possibility to application of a variety of sensors with high sensitivity and high stability to various environment conditions.","abstract_html":"Fabrication of polymeric micro/nanotubes is receiving increasing attention because of their potential applications in microfluidic, catalysis, tissue engineering, drug delivery, photonics, sensing, and so on. Main ingredients of polymeric micro/nanotube structures, however, have been mostly limited to single component polymers. Polymer composite that has broad applications as one-dimensional (1-D) fibers, wires, or cables by its enhanced mechanical property and thermochemical stability is largely unexplored as a form of hollow microtube structure.Integration of micro/nanotubes with various electrical, chemical or biological properties has been more and more important in bio- or chemical sensors. Here, one of the issues is to regulate the scales of tubes (diameters and wall thicknesses) as well as their positions. Conventional fabrication methods, such as self-assembly, templating, electrospinning, co-electrospinning, wetting, TUFT(tube by fiber template) process, self rolling, co-extrusion method, direct laser polymerization, and solvent evaporation induced phase separation, are not suitable for such regulation. For polymer composite microtubes, it is furthermore a challenge to well regulate their scales, even if successfully fabricated.In this study, single PMMA/PPy composite microtubes are realized by a meniscus-guided approach conjugated with the “coffee-ring effect” in a microscale meniscus of a colloidal solution. Furthermore, this thesis provides that individual addressable PMMA/PPy composite microtubes as stretchable chemical sensors.The first part of the thesis is the development of direct writing of single freestanding hollow microtubes of a polymer composite (poly(methyl methacrylate)/polypyrrole (PMMA/PPy)). In fact, single freestanding PMMA/PPy microtubes were fabricated by a meniscus-guided approach, based on the “coffee-ring effect” in an evaporating microscale meniscus of a colloidal solution. This method permitted to regulate the outer diameter and wall thickness of the PMMA/PPy microtubes simply by controlling the meniscus-guiding and the coffee-ring effect. Furthermore, an array of freestanding microtubes, individually controlled in scale and in position was realized.The second topic is to develop individually addressable PMMA/PPy composite microtubes as chemical sensors based on direct-writing of the composite microtubes. In fact, the composite microtubes showed a good potential as chemical sensors by demonstrating gas-concentration-driven modulation of electrical resistance for various gases such as NH3 and Volatile Organic Compounds (i.e. methanol, ethanol). The composite microtubes exhibited a higher sensitivity than those of PMMA/PPy composite microwires, much higher than those of PPy microwires at room temperature. Remarkably, strong robustness against humidity (20 to 80%) was demonstrated in the composite microtubes, due to the water-insensitivity of PMMA layer.The last topic of the thesis is to develop stretchable chemical sensor based on the PMMA/PPy composite microtubes. By writing the composite microtube into a stretchable 3-D architecture, specifically a 3-D arch shape, a very high stretchability up to ~ 110% was achieved with little change in the electrical conductance. Notably, the composite microtubes were robust against a stretching cycle up to 2 x 104. Furthermore, chemical sensitivity of the composite microtubes was not affected by stretching up to 80% for various NH3 concentrations (1 to 1000 ppm).From this work, one may challenge to research for a number of other composite materials and more complicated structures, based on the regulation of the meniscus geometry-dependent coffee-ring effect. Furthermore, individually addressable conductive polymer composite microtubes with a stretchable 3-D architecture could have possibility to application of a variety of sensors with high sensitivity and high stability to various environment conditions.","abstract_has_math":false,"creators":["원규황"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-26T04:05:41Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:2014.oak/1958"],"render_values":[{"text":"hdl:2014.oak/1958","href":null,"code":true}]},{"key":"mods:identifier.other","label":"Mods Identifier Other","values":["OAK-2014-01456"],"render_values":[{"text":"OAK-2014-01456","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001622820","outbound_label":"Repository record","outbound_source":"mods:identifier.uri","record_url":"http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001622820","record_label":"Repository record","record_kind":"record","record_source":"mods:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Apohang%3Aoai%3Aoasis.postech.ac.kr%3A2014.oak%2F1958","prefix":"oai_dc"},"source_record":{"url":"http://oasis.postech.ac.kr/oai/request?verb=GetRecord&metadataPrefix=mets&identifier=oai%3Aoasis.postech.ac.kr%3A2014.oak%2F1958","prefix":"mets"},"metadata_groups":[{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:2014.oak/1958"]},{"key":"mods:identifier.other","label":"Mods Identifier Other","values":["OAK-2014-01456"]},{"key":"mods:identifier.uri","label":"Mods Identifier URI","values":["http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001622820"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.other","label":"Dc Description Other","values":["Fabrication of polymeric micro/nanotubes is receiving increasing attention because of their potential applications in microfluidic, catalysis, tissue engineering, drug delivery, photonics, sensing, and so on. Main ingredients of polymeric micro/nanotube structures, however, have been mostly limited to single component polymers. Polymer composite that has broad applications as one-dimensional (1-D) fibers, wires, or cables by its enhanced mechanical property and thermochemical stability is largely unexplored as a form of hollow microtube structure.Integration of micro/nanotubes with various electrical, chemical or biological properties has been more and more important in bio- or chemical sensors. Here, one of the issues is to regulate the scales of tubes (diameters and wall thicknesses) as well as their positions. Conventional fabrication methods, such as self-assembly, templating, electrospinning, co-electrospinning, wetting, TUFT(tube by fiber template) process, self rolling, co-extrusion method, direct laser polymerization, and solvent evaporation induced phase separation, are not suitable for such regulation. For polymer composite microtubes, it is furthermore a challenge to well regulate their scales, even if successfully fabricated.In this study, single PMMA/PPy composite microtubes are realized by a meniscus-guided approach conjugated with the “coffee-ring effect” in a microscale meniscus of a colloidal solution. Furthermore, this thesis provides that individual addressable PMMA/PPy composite microtubes as stretchable chemical sensors.The first part of the thesis is the development of direct writing of single freestanding hollow microtubes of a polymer composite (poly(methyl methacrylate)/polypyrrole (PMMA/PPy)). In fact, single freestanding PMMA/PPy microtubes were fabricated by a meniscus-guided approach, based on the “coffee-ring effect” in an evaporating microscale meniscus of a colloidal solution. This method permitted to regulate the outer diameter and wall thickness of the PMMA/PPy microtubes simply by controlling the meniscus-guiding and the coffee-ring effect. Furthermore, an array of freestanding microtubes, individually controlled in scale and in position was realized.The second topic is to develop individually addressable PMMA/PPy composite microtubes as chemical sensors based on direct-writing of the composite microtubes. In fact, the composite microtubes showed a good potential as chemical sensors by demonstrating gas-concentration-driven modulation of electrical resistance for various gases such as NH3 and Volatile Organic Compounds (i.e. methanol, ethanol). The composite microtubes exhibited a higher sensitivity than those of PMMA/PPy composite microwires, much higher than those of PPy microwires at room temperature. Remarkably, strong robustness against humidity (20 to 80%) was demonstrated in the composite microtubes, due to the water-insensitivity of PMMA layer.The last topic of the thesis is to develop stretchable chemical sensor based on the PMMA/PPy composite microtubes. By writing the composite microtube into a stretchable 3-D architecture, specifically a 3-D arch shape, a very high stretchability up to ~ 110% was achieved with little change in the electrical conductance. Notably, the composite microtubes were robust against a stretching cycle up to 2 x 104. Furthermore, chemical sensitivity of the composite microtubes was not affected by stretching up to 80% for various NH3 concentrations (1 to 1000 ppm).From this work, one may challenge to research for a number of other composite materials and more complicated structures, based on the regulation of the meniscus geometry-dependent coffee-ring effect. Furthermore, individually addressable conductive polymer composite microtubes with a stretchable 3-D architecture could have possibility to application of a variety of sensors with high sensitivity and high stability to various environment conditions."]},{"key":"dc:title","label":"Title","values":["Single PMMA/PPy composite microtubes as chemical sensors"]},{"key":"mods:accesscondition.useandreproduction","label":"Mods Accesscondition Useandreproduction","values":["BY_NC_ND"]},{"key":"mods:dateaccessioned","label":"Mods Dateaccessioned","values":["2014-12-01T11:48:51Z"]},{"key":"mods:dateavailable","label":"Mods Dateavailable","values":["2014-12-01T11:48:51Z"]},{"key":"mods:namepart","label":"Mods Namepart","values":["원규황","일반대학원 신소재공학과","포항공과대학교"]},{"key":"mods:roleterm.text","label":"Mods Roleterm Text","values":["author","college","department"]}]}],"canonical_facts":{"dc:date.issued":["2014"],"dc:description.other":["Fabrication of polymeric micro/nanotubes is receiving increasing attention because of their potential applications in microfluidic, catalysis, tissue engineering, drug delivery, photonics, sensing, and so on. Main ingredients of polymeric micro/nanotube structures, however, have been mostly limited to single component polymers. Polymer composite that has broad applications as one-dimensional (1-D) fibers, wires, or cables by its enhanced mechanical property and thermochemical stability is largely unexplored as a form of hollow microtube structure.Integration of micro/nanotubes with various electrical, chemical or biological properties has been more and more important in bio- or chemical sensors. Here, one of the issues is to regulate the scales of tubes (diameters and wall thicknesses) as well as their positions. Conventional fabrication methods, such as self-assembly, templating, electrospinning, co-electrospinning, wetting, TUFT(tube by fiber template) process, self rolling, co-extrusion method, direct laser polymerization, and solvent evaporation induced phase separation, are not suitable for such regulation. For polymer composite microtubes, it is furthermore a challenge to well regulate their scales, even if successfully fabricated.In this study, single PMMA/PPy composite microtubes are realized by a meniscus-guided approach conjugated with the “coffee-ring effect” in a microscale meniscus of a colloidal solution. Furthermore, this thesis provides that individual addressable PMMA/PPy composite microtubes as stretchable chemical sensors.The first part of the thesis is the development of direct writing of single freestanding hollow microtubes of a polymer composite (poly(methyl methacrylate)/polypyrrole (PMMA/PPy)). In fact, single freestanding PMMA/PPy microtubes were fabricated by a meniscus-guided approach, based on the “coffee-ring effect” in an evaporating microscale meniscus of a colloidal solution. This method permitted to regulate the outer diameter and wall thickness of the PMMA/PPy microtubes simply by controlling the meniscus-guiding and the coffee-ring effect. Furthermore, an array of freestanding microtubes, individually controlled in scale and in position was realized.The second topic is to develop individually addressable PMMA/PPy composite microtubes as chemical sensors based on direct-writing of the composite microtubes. In fact, the composite microtubes showed a good potential as chemical sensors by demonstrating gas-concentration-driven modulation of electrical resistance for various gases such as NH3 and Volatile Organic Compounds (i.e. methanol, ethanol). The composite microtubes exhibited a higher sensitivity than those of PMMA/PPy composite microwires, much higher than those of PPy microwires at room temperature. Remarkably, strong robustness against humidity (20 to 80%) was demonstrated in the composite microtubes, due to the water-insensitivity of PMMA layer.The last topic of the thesis is to develop stretchable chemical sensor based on the PMMA/PPy composite microtubes. By writing the composite microtube into a stretchable 3-D architecture, specifically a 3-D arch shape, a very high stretchability up to ~ 110% was achieved with little change in the electrical conductance. Notably, the composite microtubes were robust against a stretching cycle up to 2 x 104. Furthermore, chemical sensitivity of the composite microtubes was not affected by stretching up to 80% for various NH3 concentrations (1 to 1000 ppm).From this work, one may challenge to research for a number of other composite materials and more complicated structures, based on the regulation of the meniscus geometry-dependent coffee-ring effect. Furthermore, individually addressable conductive polymer composite microtubes with a stretchable 3-D architecture could have possibility to application of a variety of sensors with high sensitivity and high stability to various environment conditions."],"dc:identifier":["hdl:2014.oak/1958"],"dc:title":["Single PMMA/PPy composite microtubes as chemical sensors"],"dc:type":["Thesis"],"mods:accesscondition.useandreproduction":["BY_NC_ND"],"mods:dateaccessioned":["2014-12-01T11:48:51Z"],"mods:dateavailable":["2014-12-01T11:48:51Z"],"mods:identifier.other":["OAK-2014-01456"],"mods:identifier.uri":["http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001622820"],"mods:namepart":["원규황","일반대학원 신소재공학과","포항공과대학교"],"mods:roleterm.text":["author","college","department"]},"updated_at":"2026-11-26T04:05:41Z"}