{"id":{"repo_id":"pohang","oai_identifier":"oai:oasis.postech.ac.kr:2014.oak/2095"},"canonical_url":"https://search.ndltd.org/etd/pohang/oai:oasis.postech.ac.kr:2014.oak/2095","repository":{"repo_id":"pohang","name":"Pohang University of Science and Technology","base_url":"http://oasis.postech.ac.kr/oai/request"},"display":{"title":"Microwave Power Module with Feedback System for Biomedical Plasma","abstract":"We designed a feedback system in a microwave plasma power module to reduce the variation of output power which can affect plasma temperature. In the feedback system, a power detector changed the coupled output power to DC voltage, and a voltage comparator compared the DC voltage to a reference voltage and then controlled the amplifier control voltage. To compare the difference between power module with feedback system and without feedback system, we checked the effect of the circuit temperature and reflected EMI on power module output and plasma temperature. We monitored the coupled power variation from the reference power (1 W) using a signal analyzer and measured the plasma temperature at 1-cm distance from the end of an argon plasma jet. With the feedback system, the power variation was 0.996 ~ 1.008 W/W and temperature variation was 40 ~ 40.5 °C for 5 min, whereas without the feedback system, power variation was 0.816 ~ 1.121 W/W and temperature variation was 38.9 ~ 42.4 °C. This feedback system will allow safe use of our plasma device in biomedical applications.","abstract_html":"We designed a feedback system in a microwave plasma power module to reduce the variation of output power which can affect plasma temperature. In the feedback system, a power detector changed the coupled output power to DC voltage, and a voltage comparator compared the DC voltage to a reference voltage and then controlled the amplifier control voltage. To compare the difference between power module with feedback system and without feedback system, we checked the effect of the circuit temperature and reflected EMI on power module output and plasma temperature. We monitored the coupled power variation from the reference power (1 W) using a signal analyzer and measured the plasma temperature at 1-cm distance from the end of an argon plasma jet. With the feedback system, the power variation was 0.996 ~ 1.008 W/W and temperature variation was 40 ~ 40.5 °C for 5 min, whereas without the feedback system, power variation was 0.816 ~ 1.121 W/W and temperature variation was 38.9 ~ 42.4 °C. This feedback system will allow safe use of our plasma device in biomedical applications.","abstract_has_math":false,"creators":["권순구"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-26T04:05:43Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:2014.oak/2095"],"render_values":[{"text":"hdl:2014.oak/2095","href":null,"code":true}]},{"key":"mods:identifier.other","label":"Mods Identifier Other","values":["OAK-2014-01593"],"render_values":[{"text":"OAK-2014-01593","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001674328","outbound_label":"Repository record","outbound_source":"mods:identifier.uri","record_url":"http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001674328","record_label":"Repository record","record_kind":"record","record_source":"mods:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Apohang%3Aoai%3Aoasis.postech.ac.kr%3A2014.oak%2F2095","prefix":"oai_dc"},"source_record":{"url":"http://oasis.postech.ac.kr/oai/request?verb=GetRecord&metadataPrefix=mets&identifier=oai%3Aoasis.postech.ac.kr%3A2014.oak%2F2095","prefix":"mets"},"metadata_groups":[{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:2014.oak/2095"]},{"key":"mods:identifier.other","label":"Mods Identifier Other","values":["OAK-2014-01593"]},{"key":"mods:identifier.uri","label":"Mods Identifier URI","values":["http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001674328"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.other","label":"Dc Description Other","values":["We designed a feedback system in a microwave plasma power module to reduce the variation of output power which can affect plasma temperature. In the feedback system, a power detector changed the coupled output power to DC voltage, and a voltage comparator compared the DC voltage to a reference voltage and then controlled the amplifier control voltage. To compare the difference between power module with feedback system and without feedback system, we checked the effect of the circuit temperature and reflected EMI on power module output and plasma temperature. We monitored the coupled power variation from the reference power (1 W) using a signal analyzer and measured the plasma temperature at 1-cm distance from the end of an argon plasma jet. With the feedback system, the power variation was 0.996 ~ 1.008 W/W and temperature variation was 40 ~ 40.5 °C for 5 min, whereas without the feedback system, power variation was 0.816 ~ 1.121 W/W and temperature variation was 38.9 ~ 42.4 °C. This feedback system will allow safe use of our plasma device in biomedical applications."]},{"key":"dc:title","label":"Title","values":["Microwave Power Module with Feedback System for Biomedical Plasma"]},{"key":"mods:accesscondition.useandreproduction","label":"Mods Accesscondition Useandreproduction","values":["BY_NC_ND"]},{"key":"mods:dateaccessioned","label":"Mods Dateaccessioned","values":["2014-12-01T11:49:05Z"]},{"key":"mods:dateavailable","label":"Mods Dateavailable","values":["2014-12-01T11:49:05Z"]},{"key":"mods:namepart","label":"Mods Namepart","values":["권순구","일반대학원 전자전기공학과","포항공과대학교"]},{"key":"mods:roleterm.text","label":"Mods Roleterm Text","values":["author","college","department"]}]}],"canonical_facts":{"dc:date.issued":["2014"],"dc:description.other":["We designed a feedback system in a microwave plasma power module to reduce the variation of output power which can affect plasma temperature. In the feedback system, a power detector changed the coupled output power to DC voltage, and a voltage comparator compared the DC voltage to a reference voltage and then controlled the amplifier control voltage. To compare the difference between power module with feedback system and without feedback system, we checked the effect of the circuit temperature and reflected EMI on power module output and plasma temperature. We monitored the coupled power variation from the reference power (1 W) using a signal analyzer and measured the plasma temperature at 1-cm distance from the end of an argon plasma jet. With the feedback system, the power variation was 0.996 ~ 1.008 W/W and temperature variation was 40 ~ 40.5 °C for 5 min, whereas without the feedback system, power variation was 0.816 ~ 1.121 W/W and temperature variation was 38.9 ~ 42.4 °C. This feedback system will allow safe use of our plasma device in biomedical applications."],"dc:identifier":["hdl:2014.oak/2095"],"dc:title":["Microwave Power Module with Feedback System for Biomedical Plasma"],"dc:type":["Thesis"],"mods:accesscondition.useandreproduction":["BY_NC_ND"],"mods:dateaccessioned":["2014-12-01T11:49:05Z"],"mods:dateavailable":["2014-12-01T11:49:05Z"],"mods:identifier.other":["OAK-2014-01593"],"mods:identifier.uri":["http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001674328"],"mods:namepart":["권순구","일반대학원 전자전기공학과","포항공과대학교"],"mods:roleterm.text":["author","college","department"]},"updated_at":"2026-11-26T04:05:43Z"}