{"id":{"repo_id":"pohang","oai_identifier":"oai:oasis.postech.ac.kr:2014.oak/2236"},"canonical_url":"https://search.ndltd.org/etd/pohang/oai:oasis.postech.ac.kr:2014.oak/2236","repository":{"repo_id":"pohang","name":"Pohang University of Science and Technology","base_url":"http://oasis.postech.ac.kr/oai/request"},"display":{"title":"PAL-XFEL 입사기에서 전자빔 최적화에 관한 연구","abstract":"Pohang Accelerator Laboratory started the construction of the fourth-generation synchrotron radiation facility, PAL-XFEL, in April 2011. This project aims to generate a 0.1 nm hard X-ray radiation using an electron beam of 0.2 nC charge and 10 GeV energy. To get operation experiences and to demonstrate the performances of sub-systems for the PAL-XFEL, Injector Test Facility (ITF) has been constructed. This facility includes an RF gun, two accelerating structures, two modulator and klystron systems, a laser system, a laser heater and several diagnostics. The current RF gun installed at ITF has four holes at the second cell so as to suppress undesirable multipole modes. PARMELA simulation has been carried out to analyse the effect of each multipole mode in the gun cavity to the emittance growth. Experimental calibration was carried out for screens, spectrometers and a transverse RF deflector. The projected emittance were measured at the end of the beamline with various conditions, i.e. various RF phases, transverse laser sizes, laser pulse lengths in order to find an optimized operating condition of an electron beam. The emittance was measured by the single quadrupole scan. The emittance of a low charge electron beam was also measured with various laser beam sizes. Requirements to measure an smaller optimized emittance value are also discussed.","abstract_html":"Pohang Accelerator Laboratory started the construction of the fourth-generation synchrotron radiation facility, PAL-XFEL, in April 2011. This project aims to generate a 0.1 nm hard X-ray radiation using an electron beam of 0.2 nC charge and 10 GeV energy. To get operation experiences and to demonstrate the performances of sub-systems for the PAL-XFEL, Injector Test Facility (ITF) has been constructed. This facility includes an RF gun, two accelerating structures, two modulator and klystron systems, a laser system, a laser heater and several diagnostics. The current RF gun installed at ITF has four holes at the second cell so as to suppress undesirable multipole modes. PARMELA simulation has been carried out to analyse the effect of each multipole mode in the gun cavity to the emittance growth. Experimental calibration was carried out for screens, spectrometers and a transverse RF deflector. The projected emittance were measured at the end of the beamline with various conditions, i.e. various RF phases, transverse laser sizes, laser pulse lengths in order to find an optimized operating condition of an electron beam. The emittance was measured by the single quadrupole scan. The emittance of a low charge electron beam was also measured with various laser beam sizes. Requirements to measure an smaller optimized emittance value are also discussed.","abstract_has_math":false,"creators":["채문식"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-26T04:05:48Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:2014.oak/2236"],"render_values":[{"text":"hdl:2014.oak/2236","href":null,"code":true}]},{"key":"mods:identifier.other","label":"Mods Identifier Other","values":["OAK-2014-01734"],"render_values":[{"text":"OAK-2014-01734","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001679561","outbound_label":"Repository record","outbound_source":"mods:identifier.uri","record_url":"http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001679561","record_label":"Repository record","record_kind":"record","record_source":"mods:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Apohang%3Aoai%3Aoasis.postech.ac.kr%3A2014.oak%2F2236","prefix":"oai_dc"},"source_record":{"url":"http://oasis.postech.ac.kr/oai/request?verb=GetRecord&metadataPrefix=mets&identifier=oai%3Aoasis.postech.ac.kr%3A2014.oak%2F2236","prefix":"mets"},"metadata_groups":[{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:2014.oak/2236"]},{"key":"mods:identifier.other","label":"Mods Identifier Other","values":["OAK-2014-01734"]},{"key":"mods:identifier.uri","label":"Mods Identifier URI","values":["http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001679561"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.other","label":"Dc Description Other","values":["Pohang Accelerator Laboratory started the construction of the fourth-generation synchrotron radiation facility, PAL-XFEL, in April 2011. This project aims to generate a 0.1 nm hard X-ray radiation using an electron beam of 0.2 nC charge and 10 GeV energy. To get operation experiences and to demonstrate the performances of sub-systems for the PAL-XFEL, Injector Test Facility (ITF) has been constructed. This facility includes an RF gun, two accelerating structures, two modulator and klystron systems, a laser system, a laser heater and several diagnostics. The current RF gun installed at ITF has four holes at the second cell so as to suppress undesirable multipole modes. PARMELA simulation has been carried out to analyse the effect of each multipole mode in the gun cavity to the emittance growth. Experimental calibration was carried out for screens, spectrometers and a transverse RF deflector. The projected emittance were measured at the end of the beamline with various conditions, i.e. various RF phases, transverse laser sizes, laser pulse lengths in order to find an optimized operating condition of an electron beam. The emittance was measured by the single quadrupole scan. The emittance of a low charge electron beam was also measured with various laser beam sizes. Requirements to measure an smaller optimized emittance value are also discussed."]},{"key":"dc:title","label":"Title","values":["PAL-XFEL 입사기에서 전자빔 최적화에 관한 연구"]},{"key":"mods:accesscondition.useandreproduction","label":"Mods Accesscondition Useandreproduction","values":["BY_NC_ND"]},{"key":"mods:dateaccessioned","label":"Mods Dateaccessioned","values":["2014-12-01T11:49:20Z"]},{"key":"mods:dateavailable","label":"Mods Dateavailable","values":["2014-12-01T11:49:20Z"]},{"key":"mods:namepart","label":"Mods Namepart","values":["채문식","일반대학원 물리학과","포항공과대학교"]},{"key":"mods:roleterm.text","label":"Mods Roleterm Text","values":["author","college","department"]}]}],"canonical_facts":{"dc:date.issued":["2014"],"dc:description.other":["Pohang Accelerator Laboratory started the construction of the fourth-generation synchrotron radiation facility, PAL-XFEL, in April 2011. This project aims to generate a 0.1 nm hard X-ray radiation using an electron beam of 0.2 nC charge and 10 GeV energy. To get operation experiences and to demonstrate the performances of sub-systems for the PAL-XFEL, Injector Test Facility (ITF) has been constructed. This facility includes an RF gun, two accelerating structures, two modulator and klystron systems, a laser system, a laser heater and several diagnostics. The current RF gun installed at ITF has four holes at the second cell so as to suppress undesirable multipole modes. PARMELA simulation has been carried out to analyse the effect of each multipole mode in the gun cavity to the emittance growth. Experimental calibration was carried out for screens, spectrometers and a transverse RF deflector. The projected emittance were measured at the end of the beamline with various conditions, i.e. various RF phases, transverse laser sizes, laser pulse lengths in order to find an optimized operating condition of an electron beam. The emittance was measured by the single quadrupole scan. The emittance of a low charge electron beam was also measured with various laser beam sizes. Requirements to measure an smaller optimized emittance value are also discussed."],"dc:identifier":["hdl:2014.oak/2236"],"dc:title":["PAL-XFEL 입사기에서 전자빔 최적화에 관한 연구"],"dc:type":["Thesis"],"mods:accesscondition.useandreproduction":["BY_NC_ND"],"mods:dateaccessioned":["2014-12-01T11:49:20Z"],"mods:dateavailable":["2014-12-01T11:49:20Z"],"mods:identifier.other":["OAK-2014-01734"],"mods:identifier.uri":["http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001679561"],"mods:namepart":["채문식","일반대학원 물리학과","포항공과대학교"],"mods:roleterm.text":["author","college","department"]},"updated_at":"2026-11-26T04:05:48Z"}