{"id":{"repo_id":"queens","oai_identifier":"oai:queensu.scholaris.ca:1974/36974"},"canonical_url":"https://search.ndltd.org/etd/queens/oai:queensu.scholaris.ca:1974/36974","repository":{"repo_id":"queens","name":"Queens University","base_url":"https://qspace.library.queensu.ca/server/oai/request"},"display":{"title":"Three-Phase Single-Stage Isolated AC–DC Converters for Electric Vehicle Battery Charging","abstract":"This thesis develops and experimentally validates two three-phase single-stage isolated ac–dc converters for electric vehicle battery charging. Both converters integrate input-current shaping, high-frequency isolation, and constant-current/constant-voltage (CC/CV) output regulation within a single power-conversion stage. The first topology is a three-phase single-stage soft-switching converter comprising a three-phase bridge, grid-side inductors, series resonant branches, a high-frequency transformer, and a passive output rectifier. A mode-based analytical model is developed to derive the input-current ripple, transferred power, operating range, and zero-voltage-switching (ZVS) condition. The model is used to establish a design procedure for selecting the dc-link voltage, passive components, and switching-frequency range. A 1.5-kW prototype supplied from a 208-V line-to-line, 60-Hz source demonstrates CC/CV regulation, wide-range ZVS, an input-current total harmonic distortion of 3.24%, a power factor of 0.994, and a peak efficiency of 94.86%. The second topology introduces a coupled-inductor-based direct power transfer (DPT) branch that transfers part of the output power directly to the secondary side and reduces the power processed by the main resonant path. A unified time-domain model is developed to derive the series-path and DPT-path powers, power-sharing ratio, input-current ripple, and ZVS condition. A 1.8-kW prototype demonstrates a DPT contribution of 21.2% at the nominal operating point, an input-current total harmonic distortion of 3.82%, a power factor of 0.993, and a full-load efficiency of 94.57%. The experimental results confirm that the proposed converters achieve isolated single-stage power conversion, high-quality input currents, CC/CV charging, and soft-switching operation. The DPT topology additionally provides an effective method for redistributing power between the internal transfer paths.","abstract_html":"This thesis develops and experimentally validates two three-phase single-stage isolated ac–dc converters for electric vehicle battery charging. Both converters integrate input-current shaping, high-frequency isolation, and constant-current/constant-voltage (CC/CV) output regulation within a single power-conversion stage. The first topology is a three-phase single-stage soft-switching converter comprising a three-phase bridge, grid-side inductors, series resonant branches, a high-frequency transformer, and a passive output rectifier. A mode-based analytical model is developed to derive the input-current ripple, transferred power, operating range, and zero-voltage-switching (ZVS) condition. The model is used to establish a design procedure for selecting the dc-link voltage, passive components, and switching-frequency range. A 1.5-kW prototype supplied from a 208-V line-to-line, 60-Hz source demonstrates CC/CV regulation, wide-range ZVS, an input-current total harmonic distortion of 3.24%, a power factor of 0.994, and a peak efficiency of 94.86%. The second topology introduces a coupled-inductor-based direct power transfer (DPT) branch that transfers part of the output power directly to the secondary side and reduces the power processed by the main resonant path. A unified time-domain model is developed to derive the series-path and DPT-path powers, power-sharing ratio, input-current ripple, and ZVS condition. A 1.8-kW prototype demonstrates a DPT contribution of 21.2% at the nominal operating point, an input-current total harmonic distortion of 3.82%, a power factor of 0.993, and a full-load efficiency of 94.57%. The experimental results confirm that the proposed converters achieve isolated single-stage power conversion, high-quality input currents, CC/CV charging, and soft-switching operation. The DPT topology additionally provides an effective method for redistributing power between the internal transfer paths.","abstract_has_math":false,"creators":["Ramezani, Mohammad"],"institution":"Queen's University at Kingston","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Pahlevani, Majid","Jain, Praveen"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-09","date_published":"2026-09","updated_at":"2026-11-19T09:08:40Z","subjects":["AC–DC power conversion","electric-vehicle charging","power-factor correction","resonant converters","single-stage converters","zero-voltage switching"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1974/36974","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1974/36974","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aqueens%3Aoai%3Aqueensu.scholaris.ca%3A1974%2F36974","prefix":"oai_dc"},"source_record":{"url":"https://qspace.library.queensu.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aqueensu.scholaris.ca%3A1974%2F36974","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Pahlevani, Majid","Jain, Praveen"]},{"key":"dc:creator","label":"Author","values":["Ramezani, Mohammad"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-24T15:03:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-09"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Canadian theses"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Queen's University at Kingston"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["AC–DC power conversion","electric-vehicle charging","power-factor correction","resonant converters","single-stage converters","zero-voltage switching"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1974/36974"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis develops and experimentally validates two three-phase single-stage isolated ac–dc converters for electric vehicle battery charging. Both converters integrate input-current shaping, high-frequency isolation, and constant-current/constant-voltage (CC/CV) output regulation within a single power-conversion stage. The first topology is a three-phase single-stage soft-switching converter comprising a three-phase bridge, grid-side inductors, series resonant branches, a high-frequency transformer, and a passive output rectifier. A mode-based analytical model is developed to derive the input-current ripple, transferred power, operating range, and zero-voltage-switching (ZVS) condition. The model is used to establish a design procedure for selecting the dc-link voltage, passive components, and switching-frequency range. A 1.5-kW prototype supplied from a 208-V line-to-line, 60-Hz source demonstrates CC/CV regulation, wide-range ZVS, an input-current total harmonic distortion of 3.24%, a power factor of 0.994, and a peak efficiency of 94.86%. The second topology introduces a coupled-inductor-based direct power transfer (DPT) branch that transfers part of the output power directly to the secondary side and reduces the power processed by the main resonant path. A unified time-domain model is developed to derive the series-path and DPT-path powers, power-sharing ratio, input-current ripple, and ZVS condition. A 1.8-kW prototype demonstrates a DPT contribution of 21.2% at the nominal operating point, an input-current total harmonic distortion of 3.82%, a power factor of 0.993, and a full-load efficiency of 94.57%. The experimental results confirm that the proposed converters achieve isolated single-stage power conversion, high-quality input currents, CC/CV charging, and soft-switching operation. The DPT topology additionally provides an effective method for redistributing power between the internal transfer paths."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["PhD"]},{"key":"dc:title","label":"Title","values":["Three-Phase Single-Stage Isolated AC–DC Converters for Electric Vehicle Battery Charging"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.supervisor":["Pahlevani, Majid","Jain, Praveen"],"dc:creator":["Ramezani, Mohammad"],"dc:date.accessioned":["2026-09-24T15:03:10Z"],"dc:date.issued":["2026-09"],"dc:description.abstract":["This thesis develops and experimentally validates two three-phase single-stage isolated ac–dc converters for electric vehicle battery charging. Both converters integrate input-current shaping, high-frequency isolation, and constant-current/constant-voltage (CC/CV) output regulation within a single power-conversion stage. The first topology is a three-phase single-stage soft-switching converter comprising a three-phase bridge, grid-side inductors, series resonant branches, a high-frequency transformer, and a passive output rectifier. A mode-based analytical model is developed to derive the input-current ripple, transferred power, operating range, and zero-voltage-switching (ZVS) condition. The model is used to establish a design procedure for selecting the dc-link voltage, passive components, and switching-frequency range. A 1.5-kW prototype supplied from a 208-V line-to-line, 60-Hz source demonstrates CC/CV regulation, wide-range ZVS, an input-current total harmonic distortion of 3.24%, a power factor of 0.994, and a peak efficiency of 94.86%. The second topology introduces a coupled-inductor-based direct power transfer (DPT) branch that transfers part of the output power directly to the secondary side and reduces the power processed by the main resonant path. A unified time-domain model is developed to derive the series-path and DPT-path powers, power-sharing ratio, input-current ripple, and ZVS condition. A 1.8-kW prototype demonstrates a DPT contribution of 21.2% at the nominal operating point, an input-current total harmonic distortion of 3.82%, a power factor of 0.993, and a full-load efficiency of 94.57%. The experimental results confirm that the proposed converters achieve isolated single-stage power conversion, high-quality input currents, CC/CV charging, and soft-switching operation. The DPT topology additionally provides an effective method for redistributing power between the internal transfer paths."],"dc:description.degree":["PhD"],"dc:identifier.uri":["https://hdl.handle.net/1974/36974"],"dc:language.iso":["eng"],"dc:relation.ispartofseries":["Canadian theses"],"dc:subject":["AC–DC power conversion","electric-vehicle charging","power-factor correction","resonant converters","single-stage converters","zero-voltage switching"],"dc:title":["Three-Phase Single-Stage Isolated AC–DC Converters for Electric Vehicle Battery Charging"],"dc:type":["thesis"],"others:access_status":["open.access"],"thesis:institution_name":["Queen's University at Kingston"]},"updated_at":"2026-11-19T09:08:40Z"}