{"id":{"repo_id":"queens","oai_identifier":"oai:queensu.scholaris.ca:1974/36980"},"canonical_url":"https://search.ndltd.org/etd/queens/oai:queensu.scholaris.ca:1974/36980","repository":{"repo_id":"queens","name":"Queens University","base_url":"https://qspace.library.queensu.ca/server/oai/request"},"display":{"title":"A Deep Learning Framework for Vision-Based Intraocular Pressure Monitoring Using Microfluidic Contact Lenses","abstract":"Continuous monitoring of intraocular pressure (IOP) has the potential to capture pressure variations that may be missed by isolated clinical measurements. Passive microfluidic contact lenses provide a promising sensing approach by converting pressure-induced deformation into visually observable fluid displacement within an embedded channel. Automated interpretation of this response, however, is challenging because ocular images exhibit variation in illumination, geometry, reflections and eyelid occlusion, while labelled physical prototype data are limited. This thesis presents a deep learning framework for automated visual analysis of a passive microfluidic contact-lens sensing system. The principal contributions are a synthetic microfluidic data generation framework, a fluid-segmentation framework with synthetic-to-physical adaptation and a fluid endpoint-localization framework incorporating delta refinement. Supporting image quality assessment, iris localization and eyelid-aware masking components are used for input screening, geometric alignment and realistic representation of ocular occlusion. The synthetic generation framework produced 70,933 automatically labelled image--mask pairs using real ocular-image backgrounds. Fluid segmentation achieved a Dice coefficient of 0.9974 in the synthetic domain and 0.9073 on physical prototype images following adaptation, with a prototype Intersection over Union (IoU) of 0.8304. For endpoint localization, delta refinement reduced the mean error from 22.6 to 5.8 pixels on simulated images and from 35.3 to 16.8 pixels on physical prototype images. These results demonstrate the feasibility of using synthetic data to support vision-based interpretation of a microfluidic contact-lens sensor while also revealing a performance gap between simulated and physical imaging conditions. The framework establishes a foundation for extracting visual fluid displacement; calibration of this response to quantitative IOP remains future work.","abstract_html":"Continuous monitoring of intraocular pressure (IOP) has the potential to capture pressure variations that may be missed by isolated clinical measurements. Passive microfluidic contact lenses provide a promising sensing approach by converting pressure-induced deformation into visually observable fluid displacement within an embedded channel. Automated interpretation of this response, however, is challenging because ocular images exhibit variation in illumination, geometry, reflections and eyelid occlusion, while labelled physical prototype data are limited. This thesis presents a deep learning framework for automated visual analysis of a passive microfluidic contact-lens sensing system. The principal contributions are a synthetic microfluidic data generation framework, a fluid-segmentation framework with synthetic-to-physical adaptation and a fluid endpoint-localization framework incorporating delta refinement. Supporting image quality assessment, iris localization and eyelid-aware masking components are used for input screening, geometric alignment and realistic representation of ocular occlusion. The synthetic generation framework produced 70,933 automatically labelled image--mask pairs using real ocular-image backgrounds. Fluid segmentation achieved a Dice coefficient of 0.9974 in the synthetic domain and 0.9073 on physical prototype images following adaptation, with a prototype Intersection over Union (IoU) of 0.8304. For endpoint localization, delta refinement reduced the mean error from 22.6 to 5.8 pixels on simulated images and from 35.3 to 16.8 pixels on physical prototype images. These results demonstrate the feasibility of using synthetic data to support vision-based interpretation of a microfluidic contact-lens sensor while also revealing a performance gap between simulated and physical imaging conditions. The framework establishes a foundation for extracting visual fluid displacement; calibration of this response to quantitative IOP remains future work.","abstract_has_math":false,"creators":["JACOB, JUSTIN"],"institution":"Queen's University at Kingston","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Greenspan, Michael","Lai, Yong Jun"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-09-23","date_published":"2026-09-23","updated_at":"2026-11-19T09:15:42Z","subjects":["Computer Vision","Deep Learning","Intraocular Pressure","Microfluidic Contact Lens","Synthetic Data","Semantic Segmentation","Ocular Imaging","Endpoint Localization","Synthetic-to-Physical Transfer"],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1974/36980","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1974/36980","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aqueens%3Aoai%3Aqueensu.scholaris.ca%3A1974%2F36980","prefix":"oai_dc"},"source_record":{"url":"https://qspace.library.queensu.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aqueensu.scholaris.ca%3A1974%2F36980","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Greenspan, Michael","Lai, Yong Jun"]},{"key":"dc:creator","label":"Author","values":["JACOB, JUSTIN"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-24T15:17:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-09-23"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Canadian theses"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Queen's University at Kingston"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computer Vision","Deep Learning","Intraocular Pressure","Microfluidic Contact Lens","Synthetic Data","Semantic Segmentation","Ocular Imaging","Endpoint Localization","Synthetic-to-Physical Transfer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1974/36980"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Continuous monitoring of intraocular pressure (IOP) has the potential to capture pressure variations that may be missed by isolated clinical measurements. Passive microfluidic contact lenses provide a promising sensing approach by converting pressure-induced deformation into visually observable fluid displacement within an embedded channel. Automated interpretation of this response, however, is challenging because ocular images exhibit variation in illumination, geometry, reflections and eyelid occlusion, while labelled physical prototype data are limited. This thesis presents a deep learning framework for automated visual analysis of a passive microfluidic contact-lens sensing system. The principal contributions are a synthetic microfluidic data generation framework, a fluid-segmentation framework with synthetic-to-physical adaptation and a fluid endpoint-localization framework incorporating delta refinement. Supporting image quality assessment, iris localization and eyelid-aware masking components are used for input screening, geometric alignment and realistic representation of ocular occlusion. The synthetic generation framework produced 70,933 automatically labelled image--mask pairs using real ocular-image backgrounds. Fluid segmentation achieved a Dice coefficient of 0.9974 in the synthetic domain and 0.9073 on physical prototype images following adaptation, with a prototype Intersection over Union (IoU) of 0.8304. For endpoint localization, delta refinement reduced the mean error from 22.6 to 5.8 pixels on simulated images and from 35.3 to 16.8 pixels on physical prototype images. These results demonstrate the feasibility of using synthetic data to support vision-based interpretation of a microfluidic contact-lens sensor while also revealing a performance gap between simulated and physical imaging conditions. The framework establishes a foundation for extracting visual fluid displacement; calibration of this response to quantitative IOP remains future work."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.A.Sc."]},{"key":"dc:title","label":"Title","values":["A Deep Learning Framework for Vision-Based Intraocular Pressure Monitoring Using Microfluidic Contact Lenses"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.supervisor":["Greenspan, Michael","Lai, Yong Jun"],"dc:creator":["JACOB, JUSTIN"],"dc:date.accessioned":["2026-09-24T15:17:38Z"],"dc:date.issued":["2026-09-23"],"dc:description.abstract":["Continuous monitoring of intraocular pressure (IOP) has the potential to capture pressure variations that may be missed by isolated clinical measurements. Passive microfluidic contact lenses provide a promising sensing approach by converting pressure-induced deformation into visually observable fluid displacement within an embedded channel. Automated interpretation of this response, however, is challenging because ocular images exhibit variation in illumination, geometry, reflections and eyelid occlusion, while labelled physical prototype data are limited. This thesis presents a deep learning framework for automated visual analysis of a passive microfluidic contact-lens sensing system. The principal contributions are a synthetic microfluidic data generation framework, a fluid-segmentation framework with synthetic-to-physical adaptation and a fluid endpoint-localization framework incorporating delta refinement. Supporting image quality assessment, iris localization and eyelid-aware masking components are used for input screening, geometric alignment and realistic representation of ocular occlusion. The synthetic generation framework produced 70,933 automatically labelled image--mask pairs using real ocular-image backgrounds. Fluid segmentation achieved a Dice coefficient of 0.9974 in the synthetic domain and 0.9073 on physical prototype images following adaptation, with a prototype Intersection over Union (IoU) of 0.8304. For endpoint localization, delta refinement reduced the mean error from 22.6 to 5.8 pixels on simulated images and from 35.3 to 16.8 pixels on physical prototype images. These results demonstrate the feasibility of using synthetic data to support vision-based interpretation of a microfluidic contact-lens sensor while also revealing a performance gap between simulated and physical imaging conditions. The framework establishes a foundation for extracting visual fluid displacement; calibration of this response to quantitative IOP remains future work."],"dc:description.degree":["M.A.Sc."],"dc:identifier.uri":["https://hdl.handle.net/1974/36980"],"dc:language.iso":["eng"],"dc:relation.ispartofseries":["Canadian theses"],"dc:rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:subject":["Computer Vision","Deep Learning","Intraocular Pressure","Microfluidic Contact Lens","Synthetic Data","Semantic Segmentation","Ocular Imaging","Endpoint Localization","Synthetic-to-Physical Transfer"],"dc:title":["A Deep Learning Framework for Vision-Based Intraocular Pressure Monitoring Using Microfluidic Contact Lenses"],"dc:type":["thesis"],"others:access_status":["open.access"],"thesis:institution_name":["Queen's University at Kingston"]},"updated_at":"2026-11-19T09:15:42Z"}