{"id":{"repo_id":"queens","oai_identifier":"oai:queensu.scholaris.ca:1974/37055"},"canonical_url":"https://search.ndltd.org/etd/queens/oai:queensu.scholaris.ca:1974/37055","repository":{"repo_id":"queens","name":"Queens University","base_url":"https://qspace.library.queensu.ca/server/oai/request"},"display":{"title":"Reinforcement learning-based energy management of battery-supercapacitor hybrid energy storage systems in electric vehicles","abstract":"Battery-supercapacitor hybrid energy storage systems (HESSs) combine the high energy density of batteries with the high power capability of supercapacitors. Their performance depends on both the power-converter architecture and the energy-management system (EMS). This thesis investigates the coordinated design of converter architecture and EMS for electric vehicles (EVs). First, HESS converter architectures are classified as dual-stage, single-stage, and quasi-stage systems, while EMS methods are reviewed as rule-based, optimization-based, machine-learning-based, and hybrid approaches. The review shows that converter topology determines the feasible source-power paths, control variables, and operating constraints available to the EMS. The first original study considers a fully active dual-stage HESS with separate bidirectional dc-dc converters. This structure enables independent source-current regulation and a continuous battery-current action. Deep deterministic policy gradient, soft actor-critic, and proximal policy optimization (PPO) are compared under a common plant, reward function, and training framework. The agents are trained using the Worldwide Harmonized Light Vehicles Test Procedure (WLTP) and evaluated under the unseen Urban Dynamometer Driving Schedule (UDDS). Among the evaluated learning methods, PPO provides the lowest battery root-mean-square current, current standard deviation, and peak discharge current. The second study considers a neutral-point-clamped-derived single-stage multi-source inverter. Since the battery and supercapacitor currents cannot be commanded independently, the EMS is formulated as discrete selection among three space-vector-modulation operating modes. A discrete-action PPO policy is trained using UDDS and evaluated under the unseen WLTP and New York City Cycle. Relative to a rule-based EMS, it reduces battery root-mean-square current by 35.37% and 39.33%, and peak absolute battery current by 27.78% and 33.49%, under the two cycles, respectively. The fixed trained policies are also evaluated using OPAL-RT software-in-the-loop implementations. Overall, the results show that the EMS formulation should reflect the physical control freedom provided by the converter architecture: continuous source-current allocation is enabled by the investigated dual-stage system, whereas topology-dependent discrete mode selection is adopted for the investigated single-stage system.","abstract_html":"Battery-supercapacitor hybrid energy storage systems (HESSs) combine the high energy density of batteries with the high power capability of supercapacitors. Their performance depends on both the power-converter architecture and the energy-management system (EMS). This thesis investigates the coordinated design of converter architecture and EMS for electric vehicles (EVs). First, HESS converter architectures are classified as dual-stage, single-stage, and quasi-stage systems, while EMS methods are reviewed as rule-based, optimization-based, machine-learning-based, and hybrid approaches. The review shows that converter topology determines the feasible source-power paths, control variables, and operating constraints available to the EMS. The first original study considers a fully active dual-stage HESS with separate bidirectional dc-dc converters. This structure enables independent source-current regulation and a continuous battery-current action. Deep deterministic policy gradient, soft actor-critic, and proximal policy optimization (PPO) are compared under a common plant, reward function, and training framework. The agents are trained using the Worldwide Harmonized Light Vehicles Test Procedure (WLTP) and evaluated under the unseen Urban Dynamometer Driving Schedule (UDDS). Among the evaluated learning methods, PPO provides the lowest battery root-mean-square current, current standard deviation, and peak discharge current. The second study considers a neutral-point-clamped-derived single-stage multi-source inverter. Since the battery and supercapacitor currents cannot be commanded independently, the EMS is formulated as discrete selection among three space-vector-modulation operating modes. A discrete-action PPO policy is trained using UDDS and evaluated under the unseen WLTP and New York City Cycle. Relative to a rule-based EMS, it reduces battery root-mean-square current by 35.37% and 39.33%, and peak absolute battery current by 27.78% and 33.49%, under the two cycles, respectively. The fixed trained policies are also evaluated using OPAL-RT software-in-the-loop implementations. Overall, the results show that the EMS formulation should reflect the physical control freedom provided by the converter architecture: continuous source-current allocation is enabled by the investigated dual-stage system, whereas topology-dependent discrete mode selection is adopted for the investigated single-stage system.","abstract_has_math":false,"creators":["Ranjbaran, Parisa"],"institution":"Queen's University at Kingston","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Bakhshai, Alireza","Jain, Praveen"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-09","date_published":"2026-09","updated_at":"2026-11-19T09:07:52Z","subjects":["Reinforcement learning","Energy management","Hybrid energy storage system","Electric vehicle"],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1974/37055","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1974/37055","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aqueens%3Aoai%3Aqueensu.scholaris.ca%3A1974%2F37055","prefix":"oai_dc"},"source_record":{"url":"https://qspace.library.queensu.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aqueensu.scholaris.ca%3A1974%2F37055","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Bakhshai, Alireza","Jain, Praveen"]},{"key":"dc:creator","label":"Author","values":["Ranjbaran, Parisa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-10-01T18:26:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-09"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Canadian theses"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Queen's University at Kingston"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Reinforcement learning","Energy management","Hybrid energy storage system","Electric vehicle"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1974/37055"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Battery-supercapacitor hybrid energy storage systems (HESSs) combine the high energy density of batteries with the high power capability of supercapacitors. Their performance depends on both the power-converter architecture and the energy-management system (EMS). This thesis investigates the coordinated design of converter architecture and EMS for electric vehicles (EVs). First, HESS converter architectures are classified as dual-stage, single-stage, and quasi-stage systems, while EMS methods are reviewed as rule-based, optimization-based, machine-learning-based, and hybrid approaches. The review shows that converter topology determines the feasible source-power paths, control variables, and operating constraints available to the EMS. The first original study considers a fully active dual-stage HESS with separate bidirectional dc-dc converters. This structure enables independent source-current regulation and a continuous battery-current action. Deep deterministic policy gradient, soft actor-critic, and proximal policy optimization (PPO) are compared under a common plant, reward function, and training framework. The agents are trained using the Worldwide Harmonized Light Vehicles Test Procedure (WLTP) and evaluated under the unseen Urban Dynamometer Driving Schedule (UDDS). Among the evaluated learning methods, PPO provides the lowest battery root-mean-square current, current standard deviation, and peak discharge current. The second study considers a neutral-point-clamped-derived single-stage multi-source inverter. Since the battery and supercapacitor currents cannot be commanded independently, the EMS is formulated as discrete selection among three space-vector-modulation operating modes. A discrete-action PPO policy is trained using UDDS and evaluated under the unseen WLTP and New York City Cycle. Relative to a rule-based EMS, it reduces battery root-mean-square current by 35.37% and 39.33%, and peak absolute battery current by 27.78% and 33.49%, under the two cycles, respectively. The fixed trained policies are also evaluated using OPAL-RT software-in-the-loop implementations. Overall, the results show that the EMS formulation should reflect the physical control freedom provided by the converter architecture: continuous source-current allocation is enabled by the investigated dual-stage system, whereas topology-dependent discrete mode selection is adopted for the investigated single-stage system."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["PhD"]},{"key":"dc:title","label":"Title","values":["Reinforcement learning-based energy management of battery-supercapacitor hybrid energy storage systems in electric vehicles"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.supervisor":["Bakhshai, Alireza","Jain, Praveen"],"dc:creator":["Ranjbaran, Parisa"],"dc:date.accessioned":["2026-10-01T18:26:18Z"],"dc:date.issued":["2026-09"],"dc:description.abstract":["Battery-supercapacitor hybrid energy storage systems (HESSs) combine the high energy density of batteries with the high power capability of supercapacitors. Their performance depends on both the power-converter architecture and the energy-management system (EMS). This thesis investigates the coordinated design of converter architecture and EMS for electric vehicles (EVs). First, HESS converter architectures are classified as dual-stage, single-stage, and quasi-stage systems, while EMS methods are reviewed as rule-based, optimization-based, machine-learning-based, and hybrid approaches. The review shows that converter topology determines the feasible source-power paths, control variables, and operating constraints available to the EMS. The first original study considers a fully active dual-stage HESS with separate bidirectional dc-dc converters. This structure enables independent source-current regulation and a continuous battery-current action. Deep deterministic policy gradient, soft actor-critic, and proximal policy optimization (PPO) are compared under a common plant, reward function, and training framework. The agents are trained using the Worldwide Harmonized Light Vehicles Test Procedure (WLTP) and evaluated under the unseen Urban Dynamometer Driving Schedule (UDDS). Among the evaluated learning methods, PPO provides the lowest battery root-mean-square current, current standard deviation, and peak discharge current. The second study considers a neutral-point-clamped-derived single-stage multi-source inverter. Since the battery and supercapacitor currents cannot be commanded independently, the EMS is formulated as discrete selection among three space-vector-modulation operating modes. A discrete-action PPO policy is trained using UDDS and evaluated under the unseen WLTP and New York City Cycle. Relative to a rule-based EMS, it reduces battery root-mean-square current by 35.37% and 39.33%, and peak absolute battery current by 27.78% and 33.49%, under the two cycles, respectively. The fixed trained policies are also evaluated using OPAL-RT software-in-the-loop implementations. Overall, the results show that the EMS formulation should reflect the physical control freedom provided by the converter architecture: continuous source-current allocation is enabled by the investigated dual-stage system, whereas topology-dependent discrete mode selection is adopted for the investigated single-stage system."],"dc:description.degree":["PhD"],"dc:identifier.uri":["https://hdl.handle.net/1974/37055"],"dc:language.iso":["eng"],"dc:relation.ispartofseries":["Canadian theses"],"dc:rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:subject":["Reinforcement learning","Energy management","Hybrid energy storage system","Electric vehicle"],"dc:title":["Reinforcement learning-based energy management of battery-supercapacitor hybrid energy storage systems in electric vehicles"],"dc:type":["thesis"],"others:access_status":["open.access"],"thesis:institution_name":["Queen's University at Kingston"]},"updated_at":"2026-11-19T09:07:52Z"}