{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-10054"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-10054","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Wireless Sensor Platform for Pulse Oximetry","abstract":"Pulse rate and oxygen saturation are two important clinical measurements that indicate the state of a person’s essential body functions. Oxygen saturation is the measurement of oxygenated hemoglobin in arterial blood i.e. it indicates the level of oxygen in the blood. Pulse oximeters, consisting of LEDs and photodetectors, offer a simple and low cost means of monitoring both pulse rate and blood oxygen saturation non-invasively. The primary objective of this project was to develop a wireless platform for MEMS devices. For this project, a pulse oximeter was also developed as a demonstration vehicle for this wireless platform. A microcontroller and a Bluetooth module was used to transmit the data from the sensor to the smartphone and an Android program was developed as a part of the project to connect with the Bluetooth module and receive, plot and save the data. Once the sensor and Android application were developed, the pulse rate and oxygen saturation measurements were compared to measurements taken by a commercial pulse oximeter to determine the accuracy of the device. The sensor was able to accurately measure with an average error percentage of ±2.86% and ±1.08% for pulse rate and oxygen saturation respectively.","abstract_html":"Pulse rate and oxygen saturation are two important clinical measurements that indicate the state of a person’s essential body functions. Oxygen saturation is the measurement of oxygenated hemoglobin in arterial blood i.e. it indicates the level of oxygen in the blood. Pulse oximeters, consisting of LEDs and photodetectors, offer a simple and low cost means of monitoring both pulse rate and blood oxygen saturation non-invasively. The primary objective of this project was to develop a wireless platform for MEMS devices. For this project, a pulse oximeter was also developed as a demonstration vehicle for this wireless platform. A microcontroller and a Bluetooth module was used to transmit the data from the sensor to the smartphone and an Android program was developed as a part of the project to connect with the Bluetooth module and receive, plot and save the data. Once the sensor and Android application were developed, the pulse rate and oxygen saturation measurements were compared to measurements taken by a commercial pulse oximeter to determine the accuracy of the device. The sensor was able to accurately measure with an average error percentage of ±2.86% and ±1.08% for pulse rate and oxygen saturation respectively.","abstract_has_math":false,"creators":["Aithal, Anusha"],"institution":null,"degree_name":"Microelectronic Engineering (MS)","degree_level":"Thesis","degree_discipline":"Microelectronic Engineering (KGCOE)","degree_department":null,"school":null,"contributors":["Lynn Fuller"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:02:26Z","subjects":["MEMS sensor","Pulse oximetry","Wireless platform"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/8901","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/8901","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-10054","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Lynn Fuller"]},{"key":"dc:creator","label":"Author","values":["Aithal, Anusha"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["1970-01-01T11:46:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-11-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Microelectronic Engineering (KGCOE)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Microelectronic Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["MEMS sensor","Pulse oximetry","Wireless platform"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/8901"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Pulse rate and oxygen saturation are two important clinical measurements that indicate the state of a person’s essential body functions. Oxygen saturation is the measurement of oxygenated hemoglobin in arterial blood i.e. it indicates the level of oxygen in the blood. Pulse oximeters, consisting of LEDs and photodetectors, offer a simple and low cost means of monitoring both pulse rate and blood oxygen saturation non-invasively. The primary objective of this project was to develop a wireless platform for MEMS devices. For this project, a pulse oximeter was also developed as a demonstration vehicle for this wireless platform. A microcontroller and a Bluetooth module was used to transmit the data from the sensor to the smartphone and an Android program was developed as a part of the project to connect with the Bluetooth module and receive, plot and save the data. Once the sensor and Android application were developed, the pulse rate and oxygen saturation measurements were compared to measurements taken by a commercial pulse oximeter to determine the accuracy of the device. The sensor was able to accurately measure with an average error percentage of ±2.86% and ±1.08% for pulse rate and oxygen saturation respectively."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>Physical copy available from RIT's Wallace Library at TK7872.D48 A48 2015</p>"]},{"key":"dc:title","label":"Title","values":["Wireless Sensor Platform for Pulse Oximetry"]}]}],"canonical_facts":{"dc:contributor":["Lynn Fuller"],"dc:creator":["Aithal, Anusha"],"dc:date.available":["1970-01-01T11:46:00Z"],"dc:date.created":["2015-11-01T07:00:00Z"],"dc:description.abstract":["Pulse rate and oxygen saturation are two important clinical measurements that indicate the state of a person’s essential body functions. Oxygen saturation is the measurement of oxygenated hemoglobin in arterial blood i.e. it indicates the level of oxygen in the blood. Pulse oximeters, consisting of LEDs and photodetectors, offer a simple and low cost means of monitoring both pulse rate and blood oxygen saturation non-invasively. The primary objective of this project was to develop a wireless platform for MEMS devices. For this project, a pulse oximeter was also developed as a demonstration vehicle for this wireless platform. A microcontroller and a Bluetooth module was used to transmit the data from the sensor to the smartphone and an Android program was developed as a part of the project to connect with the Bluetooth module and receive, plot and save the data. Once the sensor and Android application were developed, the pulse rate and oxygen saturation measurements were compared to measurements taken by a commercial pulse oximeter to determine the accuracy of the device. The sensor was able to accurately measure with an average error percentage of ±2.86% and ±1.08% for pulse rate and oxygen saturation respectively."],"dc:description.note":["<p>Physical copy available from RIT's Wallace Library at TK7872.D48 A48 2015</p>"],"dc:identifier":["https://repository.rit.edu/theses/8901"],"dc:subject":["MEMS sensor","Pulse oximetry","Wireless platform"],"dc:title":["Wireless Sensor Platform for Pulse Oximetry"],"thesis:degree_discipline":["Microelectronic Engineering (KGCOE)"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Microelectronic Engineering (MS)"]},"updated_at":"2026-11-19T09:02:26Z"}