{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-10097"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-10097","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"CMOS Compatible 3-Axis Magnetic Field Sensor using Hall Effect Sensing","abstract":"The purpose of this study is to design, fabricate and test a CMOS compatible 3-axis Hall effect sensor capable of detecting the earth’s magnetic field, with strength’s of ~50 μT. Preliminary testing of N-well Van Der Pauw structures using strong neodymium magnets showed proof of concept for hall voltage sensing, however, poor geometry of the structures led to a high offset voltage. A 1-axis Hall effect sensor was designed, fabricated and tested with a sensitivity of 1.12x10-3 mV/Gauss using the RIT metal gate PMOS process. Poor geometry and insufficient design produced an offset voltage of 0.1238 volts in the 1-axis design; prevented sensing of the earth’s magnetic field. The new design features improved geometry for sensing application, improved sensitivity and use the RIT sub-CMOS process. The completed 2-axis device showed an average sensitivity to large magnetic fields of 0.0258 μV/Gauss at 10 mA supply current.","abstract_html":"The purpose of this study is to design, fabricate and test a CMOS compatible 3-axis Hall effect sensor capable of detecting the earth’s magnetic field, with strength’s of ~50 μT. Preliminary testing of N-well Van Der Pauw structures using strong neodymium magnets showed proof of concept for hall voltage sensing, however, poor geometry of the structures led to a high offset voltage. A 1-axis Hall effect sensor was designed, fabricated and tested with a sensitivity of 1.12x10-3 mV/Gauss using the RIT metal gate PMOS process. Poor geometry and insufficient design produced an offset voltage of 0.1238 volts in the 1-axis design; prevented sensing of the earth’s magnetic field. The new design features improved geometry for sensing application, improved sensitivity and use the RIT sub-CMOS process. The completed 2-axis device showed an average sensitivity to large magnetic fields of 0.0258 μV/Gauss at 10 mA supply current.","abstract_has_math":false,"creators":["Locke, Joshua R"],"institution":null,"degree_name":"Microelectronic Engineering (MS)","degree_level":"Thesis","degree_discipline":"Microelectronic Engineering (KGCOE)","degree_department":null,"school":null,"contributors":["Lynn F. Fuller"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:02:26Z","subjects":["CMOS processing","Hall effect","Magnetic sensing","MEMS"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/8939","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/8939","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-10097","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Lynn F. Fuller"]},{"key":"dc:creator","label":"Author","values":["Locke, Joshua R"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["1970-01-01T11:46:31Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-02-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Microelectronic Engineering (KGCOE)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Microelectronic Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["CMOS processing","Hall effect","Magnetic sensing","MEMS"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/8939"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this study is to design, fabricate and test a CMOS compatible 3-axis Hall effect sensor capable of detecting the earth’s magnetic field, with strength’s of ~50 μT. Preliminary testing of N-well Van Der Pauw structures using strong neodymium magnets showed proof of concept for hall voltage sensing, however, poor geometry of the structures led to a high offset voltage. A 1-axis Hall effect sensor was designed, fabricated and tested with a sensitivity of 1.12x10-3 mV/Gauss using the RIT metal gate PMOS process. Poor geometry and insufficient design produced an offset voltage of 0.1238 volts in the 1-axis design; prevented sensing of the earth’s magnetic field. The new design features improved geometry for sensing application, improved sensitivity and use the RIT sub-CMOS process. The completed 2-axis device showed an average sensitivity to large magnetic fields of 0.0258 μV/Gauss at 10 mA supply current."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>Physical copy available from RIT's Wallace Library at TK7872.H3 L63 2015</p>"]},{"key":"dc:title","label":"Title","values":["CMOS Compatible 3-Axis Magnetic Field Sensor using Hall Effect Sensing"]}]}],"canonical_facts":{"dc:contributor":["Lynn F. Fuller"],"dc:creator":["Locke, Joshua R"],"dc:date.available":["1970-01-01T11:46:31Z"],"dc:date.created":["2015-02-01T08:00:00Z"],"dc:description.abstract":["The purpose of this study is to design, fabricate and test a CMOS compatible 3-axis Hall effect sensor capable of detecting the earth’s magnetic field, with strength’s of ~50 μT. Preliminary testing of N-well Van Der Pauw structures using strong neodymium magnets showed proof of concept for hall voltage sensing, however, poor geometry of the structures led to a high offset voltage. A 1-axis Hall effect sensor was designed, fabricated and tested with a sensitivity of 1.12x10-3 mV/Gauss using the RIT metal gate PMOS process. Poor geometry and insufficient design produced an offset voltage of 0.1238 volts in the 1-axis design; prevented sensing of the earth’s magnetic field. The new design features improved geometry for sensing application, improved sensitivity and use the RIT sub-CMOS process. The completed 2-axis device showed an average sensitivity to large magnetic fields of 0.0258 μV/Gauss at 10 mA supply current."],"dc:description.note":["<p>Physical copy available from RIT's Wallace Library at TK7872.H3 L63 2015</p>"],"dc:identifier":["https://repository.rit.edu/theses/8939"],"dc:subject":["CMOS processing","Hall effect","Magnetic sensing","MEMS"],"dc:title":["CMOS Compatible 3-Axis Magnetic Field Sensor using Hall Effect Sensing"],"thesis:degree_discipline":["Microelectronic Engineering (KGCOE)"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Microelectronic Engineering (MS)"]},"updated_at":"2026-11-19T09:02:26Z"}