{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-10380"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-10380","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Cardiac Inter Beat Interval and Atrial Fibrillation Detection using Video Plethysmography","abstract":"Facial videoplethysmography provides non-contact measurement of heart activity based on blood volume pulsations detected in facial tissue. Typically, the signal is extracted using a simple webcam followed by elaborated signal processing methods, and provides limited accuracy of time-domain characteristics. In this study, we explore the possibility of providing accurate time-domain pulse and inter-beat interval measurements using a high- quality image sensor camera and various signal processing approaches, and use these measurements to diagnose atrial fibrillation. We capture synchronized signals using a high- quality camera, a simple webcam, an earlobe photoplethysmography sensor, and a body- surface electrocardiogram from a large group of subjects, including subjects diagnosed with cardiac arrhythmias. All signals are processed using both blind source separation and color conversion. We then assess accuracy of IBI detection, heart rate variability estimation, and atrial fibrillation diagnose by comparing to a body-surface electrocardiogram. We present a new heart variability indicator for blood volume pulsating signals. Our results demonstrate that the accuracy of a facial VPG system is greatly improved when using a high-quality camera. Coupling the high-quality camera with color conversion from RGB to Hue provides a level of accuracy equivalent to that of commercially available photoplethysmography sensors, and offers a non-contact alternative to current technology for heart rate variability assessment and atrial fibrillation screening.","abstract_html":"Facial videoplethysmography provides non-contact measurement of heart activity based on blood volume pulsations detected in facial tissue. Typically, the signal is extracted using a simple webcam followed by elaborated signal processing methods, and provides limited accuracy of time-domain characteristics. In this study, we explore the possibility of providing accurate time-domain pulse and inter-beat interval measurements using a high- quality image sensor camera and various signal processing approaches, and use these measurements to diagnose atrial fibrillation. We capture synchronized signals using a high- quality camera, a simple webcam, an earlobe photoplethysmography sensor, and a body- surface electrocardiogram from a large group of subjects, including subjects diagnosed with cardiac arrhythmias. All signals are processed using both blind source separation and color conversion. We then assess accuracy of IBI detection, heart rate variability estimation, and atrial fibrillation diagnose by comparing to a body-surface electrocardiogram. We present a new heart variability indicator for blood volume pulsating signals. Our results demonstrate that the accuracy of a facial VPG system is greatly improved when using a high-quality camera. Coupling the high-quality camera with color conversion from RGB to Hue provides a level of accuracy equivalent to that of commercially available photoplethysmography sensors, and offers a non-contact alternative to current technology for heart rate variability assessment and atrial fibrillation screening.","abstract_has_math":false,"creators":["Hernandez Guzman, Jairo"],"institution":null,"degree_name":"Electrical Engineering (MS)","degree_level":"Thesis","degree_discipline":"Electrical Engineering (KGCOE)","degree_department":null,"school":null,"contributors":["Gill R. Tsouri"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:02:48Z","subjects":["None provided"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/9224","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/9224","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-10380","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gill R. Tsouri"]},{"key":"dc:creator","label":"Author","values":["Hernandez Guzman, Jairo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2017-09-26T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-06-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering (KGCOE)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Electrical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["None provided"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/9224"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Facial videoplethysmography provides non-contact measurement of heart activity based on blood volume pulsations detected in facial tissue. Typically, the signal is extracted using a simple webcam followed by elaborated signal processing methods, and provides limited accuracy of time-domain characteristics. In this study, we explore the possibility of providing accurate time-domain pulse and inter-beat interval measurements using a high- quality image sensor camera and various signal processing approaches, and use these measurements to diagnose atrial fibrillation. We capture synchronized signals using a high- quality camera, a simple webcam, an earlobe photoplethysmography sensor, and a body- surface electrocardiogram from a large group of subjects, including subjects diagnosed with cardiac arrhythmias. All signals are processed using both blind source separation and color conversion. We then assess accuracy of IBI detection, heart rate variability estimation, and atrial fibrillation diagnose by comparing to a body-surface electrocardiogram. We present a new heart variability indicator for blood volume pulsating signals. Our results demonstrate that the accuracy of a facial VPG system is greatly improved when using a high-quality camera. Coupling the high-quality camera with color conversion from RGB to Hue provides a level of accuracy equivalent to that of commercially available photoplethysmography sensors, and offers a non-contact alternative to current technology for heart rate variability assessment and atrial fibrillation screening."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>Physical copy available from RIT's Wallace Library at RC734.P55 H47 2016</p>"]},{"key":"dc:title","label":"Title","values":["Cardiac Inter Beat Interval and Atrial Fibrillation Detection using Video Plethysmography"]}]}],"canonical_facts":{"dc:contributor":["Gill R. Tsouri"],"dc:creator":["Hernandez Guzman, Jairo"],"dc:date.available":["2017-09-26T07:00:00Z"],"dc:date.created":["2016-06-01T07:00:00Z"],"dc:description.abstract":["Facial videoplethysmography provides non-contact measurement of heart activity based on blood volume pulsations detected in facial tissue. Typically, the signal is extracted using a simple webcam followed by elaborated signal processing methods, and provides limited accuracy of time-domain characteristics. In this study, we explore the possibility of providing accurate time-domain pulse and inter-beat interval measurements using a high- quality image sensor camera and various signal processing approaches, and use these measurements to diagnose atrial fibrillation. We capture synchronized signals using a high- quality camera, a simple webcam, an earlobe photoplethysmography sensor, and a body- surface electrocardiogram from a large group of subjects, including subjects diagnosed with cardiac arrhythmias. All signals are processed using both blind source separation and color conversion. We then assess accuracy of IBI detection, heart rate variability estimation, and atrial fibrillation diagnose by comparing to a body-surface electrocardiogram. We present a new heart variability indicator for blood volume pulsating signals. Our results demonstrate that the accuracy of a facial VPG system is greatly improved when using a high-quality camera. Coupling the high-quality camera with color conversion from RGB to Hue provides a level of accuracy equivalent to that of commercially available photoplethysmography sensors, and offers a non-contact alternative to current technology for heart rate variability assessment and atrial fibrillation screening."],"dc:description.note":["<p>Physical copy available from RIT's Wallace Library at RC734.P55 H47 2016</p>"],"dc:identifier":["https://repository.rit.edu/theses/9224"],"dc:subject":["None provided"],"dc:title":["Cardiac Inter Beat Interval and Atrial Fibrillation Detection using Video Plethysmography"],"thesis:degree_discipline":["Electrical Engineering (KGCOE)"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Electrical Engineering (MS)"]},"updated_at":"2026-11-19T09:02:48Z"}