{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-10661"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-10661","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Comparing Economic, Environmental, and Social Effects of Central Air Conditioner Size and Thermostat Schedule Interactions","abstract":"Selecting the capacity of a central air conditioning (AC) system is based on a long list of structural factors within a home, but is normally chosen without considering effects on stakeholders outside of the home. Energy use by residential air conditioners is relevant to consumers as an expense, but also to utilities as a contributor to peak demand and to society by the resultant carbon dioxide and other emissions. In this article, we investigate how size and operational patterns of central residential air conditioners interact with stakeholder benefits and costs. The case study analyzes energy use for systems sized from 3.0-5.5 tons in single family homes in Phoenix, Arizona and quantifies the costs and benefits to homeowners, electric utilities, and society. For homeowners, larger units are preferred due to lower energy consumption, leading to lower net costs, and the ability to cool the house quickly. However, under the same conditions, a smaller AC system can provide double the potential profit to the utility from reduced generation and peak load costs. As a result of lower energy consumption, larger units have lower environmental externality costs from carbon and criteria pollutant emissions. However, a social perspective that considers homeowner, utility and externality costs together results in an overall preference for smaller units with setback schedules, driven by the value of peak demand reduction.","abstract_html":"Selecting the capacity of a central air conditioning (AC) system is based on a long list of structural factors within a home, but is normally chosen without considering effects on stakeholders outside of the home. Energy use by residential air conditioners is relevant to consumers as an expense, but also to utilities as a contributor to peak demand and to society by the resultant carbon dioxide and other emissions. In this article, we investigate how size and operational patterns of central residential air conditioners interact with stakeholder benefits and costs. The case study analyzes energy use for systems sized from 3.0-5.5 tons in single family homes in Phoenix, Arizona and quantifies the costs and benefits to homeowners, electric utilities, and society. For homeowners, larger units are preferred due to lower energy consumption, leading to lower net costs, and the ability to cool the house quickly. However, under the same conditions, a smaller AC system can provide double the potential profit to the utility from reduced generation and peak load costs. As a result of lower energy consumption, larger units have lower environmental externality costs from carbon and criteria pollutant emissions. However, a social perspective that considers homeowner, utility and externality costs together results in an overall preference for smaller units with setback schedules, driven by the value of peak demand reduction.","abstract_has_math":false,"creators":["Amoroso, Briana Elizabeth"],"institution":null,"degree_name":"Sustainable Engineering (MS)","degree_level":"Thesis","degree_discipline":"Industrial and Systems Engineering (KGCOE)","degree_department":null,"school":null,"contributors":["Katie McConky"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:03:04Z","subjects":["Air-conditioning sizing","Peak emissions","Social cost"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/9514","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/9514","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Arit%3Aoai%3Arepository.rit.edu%3Atheses-10661","prefix":"oai_dc"},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-10661","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Katie McConky"]},{"key":"dc:creator","label":"Author","values":["Amoroso, Briana Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2017-08-07T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-07-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Industrial and Systems Engineering (KGCOE)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Sustainable Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Air-conditioning sizing","Peak emissions","Social cost"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/9514"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Selecting the capacity of a central air conditioning (AC) system is based on a long list of structural factors within a home, but is normally chosen without considering effects on stakeholders outside of the home. Energy use by residential air conditioners is relevant to consumers as an expense, but also to utilities as a contributor to peak demand and to society by the resultant carbon dioxide and other emissions. In this article, we investigate how size and operational patterns of central residential air conditioners interact with stakeholder benefits and costs. The case study analyzes energy use for systems sized from 3.0-5.5 tons in single family homes in Phoenix, Arizona and quantifies the costs and benefits to homeowners, electric utilities, and society. For homeowners, larger units are preferred due to lower energy consumption, leading to lower net costs, and the ability to cool the house quickly. However, under the same conditions, a smaller AC system can provide double the potential profit to the utility from reduced generation and peak load costs. As a result of lower energy consumption, larger units have lower environmental externality costs from carbon and criteria pollutant emissions. However, a social perspective that considers homeowner, utility and externality costs together results in an overall preference for smaller units with setback schedules, driven by the value of peak demand reduction."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>Physical copy available from RIT's Wallace Library at TH7687 .A66 2017</p>"]},{"key":"dc:title","label":"Title","values":["Comparing Economic, Environmental, and Social Effects of Central Air Conditioner Size and Thermostat Schedule Interactions"]}]}],"canonical_facts":{"dc:contributor":["Katie McConky"],"dc:creator":["Amoroso, Briana Elizabeth"],"dc:date.available":["2017-08-07T07:00:00Z"],"dc:date.created":["2017-07-01T07:00:00Z"],"dc:description.abstract":["Selecting the capacity of a central air conditioning (AC) system is based on a long list of structural factors within a home, but is normally chosen without considering effects on stakeholders outside of the home. Energy use by residential air conditioners is relevant to consumers as an expense, but also to utilities as a contributor to peak demand and to society by the resultant carbon dioxide and other emissions. In this article, we investigate how size and operational patterns of central residential air conditioners interact with stakeholder benefits and costs. The case study analyzes energy use for systems sized from 3.0-5.5 tons in single family homes in Phoenix, Arizona and quantifies the costs and benefits to homeowners, electric utilities, and society. For homeowners, larger units are preferred due to lower energy consumption, leading to lower net costs, and the ability to cool the house quickly. However, under the same conditions, a smaller AC system can provide double the potential profit to the utility from reduced generation and peak load costs. As a result of lower energy consumption, larger units have lower environmental externality costs from carbon and criteria pollutant emissions. However, a social perspective that considers homeowner, utility and externality costs together results in an overall preference for smaller units with setback schedules, driven by the value of peak demand reduction."],"dc:description.note":["<p>Physical copy available from RIT's Wallace Library at TH7687 .A66 2017</p>"],"dc:identifier":["https://repository.rit.edu/theses/9514"],"dc:subject":["Air-conditioning sizing","Peak emissions","Social cost"],"dc:title":["Comparing Economic, Environmental, and Social Effects of Central Air Conditioner Size and Thermostat Schedule Interactions"],"thesis:degree_discipline":["Industrial and Systems Engineering (KGCOE)"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Sustainable Engineering (MS)"]},"updated_at":"2026-11-19T09:03:04Z"}