{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-10771"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-10771","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Control of Thermal Power System Using Adaptive Fuzzy Logic Control","abstract":"Controlling thermal power systems increases the overall system efficiency and satisfies the desired requirements. In such a large system, fuel reduction of even a small percentage leads to large energy saving. Hence, power systems are gaining significant attention from engineers and scientists. In this thesis, the uncontrolled power system for single area, two area, and three area is modelled using state space representation. Frequency deviation is simulated using MATLAB and SIMULINK. PID control is added to the system to analyze the effect of conventional control on system output response. Adaptive fuzzy logic control is added to the uncontrolled system using MATLAB Fuzzy Inference System and its effect on the system output response is measured in terms of overshoot/undershoot percentage, settling time, and steady state frequency error. Effect of adaptive fuzzy logic control is analyzed on single area, two area, and three area power system. Tie-line power exchange among areas is investigated before and after implementation of PID and adaptive fuzzy logic control. For the purpose of comparison in this thesis, a conventional PID control and an adaptive fuzzy logic control is applied to two different thermal power systems. The simulations demonstrate that adaptive fuzzy logic control is proved to be more efficient and reliable than conventional PID control in power system control problem.","abstract_html":"Controlling thermal power systems increases the overall system efficiency and satisfies the desired requirements. In such a large system, fuel reduction of even a small percentage leads to large energy saving. Hence, power systems are gaining significant attention from engineers and scientists. In this thesis, the uncontrolled power system for single area, two area, and three area is modelled using state space representation. Frequency deviation is simulated using MATLAB and SIMULINK. PID control is added to the system to analyze the effect of conventional control on system output response. Adaptive fuzzy logic control is added to the uncontrolled system using MATLAB Fuzzy Inference System and its effect on the system output response is measured in terms of overshoot/undershoot percentage, settling time, and steady state frequency error. Effect of adaptive fuzzy logic control is analyzed on single area, two area, and three area power system. Tie-line power exchange among areas is investigated before and after implementation of PID and adaptive fuzzy logic control. For the purpose of comparison in this thesis, a conventional PID control and an adaptive fuzzy logic control is applied to two different thermal power systems. The simulations demonstrate that adaptive fuzzy logic control is proved to be more efficient and reliable than conventional PID control in power system control problem.","abstract_has_math":false,"creators":["Naghshineh, Nastaran"],"institution":null,"degree_name":"Electrical Engineering (MS)","degree_level":"Thesis","degree_discipline":"Electrical Engineering (KGCOE)","degree_department":null,"school":null,"contributors":["Abdulla Ismail"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:03:11Z","subjects":["Adaptive fuzzy logic control","Control","Fuzzy logic","Multi-area power system","PID","Thermal power system"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/9615","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/9615","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-10771","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Abdulla Ismail"]},{"key":"dc:creator","label":"Author","values":["Naghshineh, Nastaran"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2017-11-03T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-09-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering (KGCOE)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Electrical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Adaptive fuzzy logic control","Control","Fuzzy logic","Multi-area power system","PID","Thermal power system"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/9615"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Controlling thermal power systems increases the overall system efficiency and satisfies the desired requirements. In such a large system, fuel reduction of even a small percentage leads to large energy saving. Hence, power systems are gaining significant attention from engineers and scientists. In this thesis, the uncontrolled power system for single area, two area, and three area is modelled using state space representation. Frequency deviation is simulated using MATLAB and SIMULINK. PID control is added to the system to analyze the effect of conventional control on system output response. Adaptive fuzzy logic control is added to the uncontrolled system using MATLAB Fuzzy Inference System and its effect on the system output response is measured in terms of overshoot/undershoot percentage, settling time, and steady state frequency error. Effect of adaptive fuzzy logic control is analyzed on single area, two area, and three area power system. Tie-line power exchange among areas is investigated before and after implementation of PID and adaptive fuzzy logic control. For the purpose of comparison in this thesis, a conventional PID control and an adaptive fuzzy logic control is applied to two different thermal power systems. The simulations demonstrate that adaptive fuzzy logic control is proved to be more efficient and reliable than conventional PID control in power system control problem."]},{"key":"dc:title","label":"Title","values":["Control of Thermal Power System Using Adaptive Fuzzy Logic Control"]}]}],"canonical_facts":{"dc:contributor":["Abdulla Ismail"],"dc:creator":["Naghshineh, Nastaran"],"dc:date.available":["2017-11-03T07:00:00Z"],"dc:date.created":["2017-09-01T07:00:00Z"],"dc:description.abstract":["Controlling thermal power systems increases the overall system efficiency and satisfies the desired requirements. In such a large system, fuel reduction of even a small percentage leads to large energy saving. Hence, power systems are gaining significant attention from engineers and scientists. In this thesis, the uncontrolled power system for single area, two area, and three area is modelled using state space representation. Frequency deviation is simulated using MATLAB and SIMULINK. PID control is added to the system to analyze the effect of conventional control on system output response. Adaptive fuzzy logic control is added to the uncontrolled system using MATLAB Fuzzy Inference System and its effect on the system output response is measured in terms of overshoot/undershoot percentage, settling time, and steady state frequency error. Effect of adaptive fuzzy logic control is analyzed on single area, two area, and three area power system. Tie-line power exchange among areas is investigated before and after implementation of PID and adaptive fuzzy logic control. For the purpose of comparison in this thesis, a conventional PID control and an adaptive fuzzy logic control is applied to two different thermal power systems. The simulations demonstrate that adaptive fuzzy logic control is proved to be more efficient and reliable than conventional PID control in power system control problem."],"dc:identifier":["https://repository.rit.edu/theses/9615"],"dc:subject":["Adaptive fuzzy logic control","Control","Fuzzy logic","Multi-area power system","PID","Thermal power system"],"dc:title":["Control of Thermal Power System Using Adaptive Fuzzy Logic Control"],"thesis:degree_discipline":["Electrical Engineering (KGCOE)"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Electrical Engineering (MS)"]},"updated_at":"2026-11-19T09:03:11Z"}