{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-11304"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-11304","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Magnetoactive Elastomer Solenoid Development and Implementation in Underwater Jet Propulsion","abstract":"The objective of this research was to develop and implement an elastomer solenoid capable of generating underwater jet propulsion for soft robot actuation. This is significant in pushing forward the progress of soft robotics by proving the viability of a new soft actuation method in addition to proving the viability of using silicone and magnetic particles as the driving mechanism for a soft actuator. The two primary aims were to effectively manufacture an elastomer solenoid core and to incorporate that core with a flexible diaphragm that actuates when a voltage is applied. This combination creates a pulse of water that is pumped out of an orifice. In practice, this was a success. The propagated magnetic field in the elastomer core was very apparent in air and displacements of 2.7 cm could be achieved for a 100 mm wide diaphragm. Underwater, the added damping force of the fluid limited the displacement of the diaphragm, however; the final device was able to pump water at 250 ml/min out of an orifice.","abstract_html":"The objective of this research was to develop and implement an elastomer solenoid capable of generating underwater jet propulsion for soft robot actuation. This is significant in pushing forward the progress of soft robotics by proving the viability of a new soft actuation method in addition to proving the viability of using silicone and magnetic particles as the driving mechanism for a soft actuator. The two primary aims were to effectively manufacture an elastomer solenoid core and to incorporate that core with a flexible diaphragm that actuates when a voltage is applied. This combination creates a pulse of water that is pumped out of an orifice. In practice, this was a success. The propagated magnetic field in the elastomer core was very apparent in air and displacements of 2.7 cm could be achieved for a 100 mm wide diaphragm. Underwater, the added damping force of the fluid limited the displacement of the diaphragm, however; the final device was able to pump water at 250 ml/min out of an orifice.","abstract_has_math":false,"creators":["Damm, Eric"],"institution":null,"degree_name":"Mechanical Engineering (MS)","degree_level":"Thesis","degree_discipline":"Mechanical Engineering (KGCOE)","degree_department":null,"school":null,"contributors":["Kathleen Lamkin-Kennard"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:03:47Z","subjects":["Diaphragm","Elastomer","Jet propulsion","Pulse","Soft robotics","Solenoid"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/10142","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/10142","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-11304","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kathleen Lamkin-Kennard"]},{"key":"dc:creator","label":"Author","values":["Damm, Eric"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-08-16T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-08-06T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering (KGCOE)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Mechanical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Diaphragm","Elastomer","Jet propulsion","Pulse","Soft robotics","Solenoid"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/10142"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this research was to develop and implement an elastomer solenoid capable of generating underwater jet propulsion for soft robot actuation. This is significant in pushing forward the progress of soft robotics by proving the viability of a new soft actuation method in addition to proving the viability of using silicone and magnetic particles as the driving mechanism for a soft actuator. The two primary aims were to effectively manufacture an elastomer solenoid core and to incorporate that core with a flexible diaphragm that actuates when a voltage is applied. This combination creates a pulse of water that is pumped out of an orifice. In practice, this was a success. The propagated magnetic field in the elastomer core was very apparent in air and displacements of 2.7 cm could be achieved for a 100 mm wide diaphragm. Underwater, the added damping force of the fluid limited the displacement of the diaphragm, however; the final device was able to pump water at 250 ml/min out of an orifice."]},{"key":"dc:title","label":"Title","values":["Magnetoactive Elastomer Solenoid Development and Implementation in Underwater Jet Propulsion"]}]}],"canonical_facts":{"dc:contributor":["Kathleen Lamkin-Kennard"],"dc:creator":["Damm, Eric"],"dc:date.available":["2019-08-16T07:00:00Z"],"dc:date.created":["2019-08-06T07:00:00Z"],"dc:description.abstract":["The objective of this research was to develop and implement an elastomer solenoid capable of generating underwater jet propulsion for soft robot actuation. This is significant in pushing forward the progress of soft robotics by proving the viability of a new soft actuation method in addition to proving the viability of using silicone and magnetic particles as the driving mechanism for a soft actuator. The two primary aims were to effectively manufacture an elastomer solenoid core and to incorporate that core with a flexible diaphragm that actuates when a voltage is applied. This combination creates a pulse of water that is pumped out of an orifice. In practice, this was a success. The propagated magnetic field in the elastomer core was very apparent in air and displacements of 2.7 cm could be achieved for a 100 mm wide diaphragm. Underwater, the added damping force of the fluid limited the displacement of the diaphragm, however; the final device was able to pump water at 250 ml/min out of an orifice."],"dc:identifier":["https://repository.rit.edu/theses/10142"],"dc:subject":["Diaphragm","Elastomer","Jet propulsion","Pulse","Soft robotics","Solenoid"],"dc:title":["Magnetoactive Elastomer Solenoid Development and Implementation in Underwater Jet Propulsion"],"thesis:degree_discipline":["Mechanical Engineering (KGCOE)"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Mechanical Engineering (MS)"]},"updated_at":"2026-11-19T09:03:47Z"}