{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-12200"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-12200","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Quantum Correlations using Classical Detectors","abstract":"Single photons are vital to quantum computing, information processing, and transportation. Popular single-photon experiments are one or two-photon interference, classification of the light source, and characterization of detectors. Currently, the most efficient detector in the telecom wavelength is the Superconducting Nanowire detector. How- ever, experiments have been successful in demonstrating single-photon measurements can be done with unconventional detectors. One such method employed an EMCCD camera to observe spatial correlations between pixels with single photons. This thesis aims to test non-single photon-counting PIN photodetectors to observe time-correlation measurement. The improved detection model uses a high-resolution 2GHz oscilloscope and a cross-correlation algorithm. Results were compared with coincidence measurements using an SNSPD and TAC module. Previous PIN-related single- photon experiments mainly used PIN avalanche detectors. We aim to accomplish the same task with Thorlabs PDA-CF 10 amplified detectors.","abstract_html":"Single photons are vital to quantum computing, information processing, and transportation. Popular single-photon experiments are one or two-photon interference, classification of the light source, and characterization of detectors. Currently, the most efficient detector in the telecom wavelength is the Superconducting Nanowire detector. How- ever, experiments have been successful in demonstrating single-photon measurements can be done with unconventional detectors. One such method employed an EMCCD camera to observe spatial correlations between pixels with single photons. This thesis aims to test non-single photon-counting PIN photodetectors to observe time-correlation measurement. The improved detection model uses a high-resolution 2GHz oscilloscope and a cross-correlation algorithm. Results were compared with coincidence measurements using an SNSPD and TAC module. Previous PIN-related single- photon experiments mainly used PIN avalanche detectors. We aim to accomplish the same task with Thorlabs PDA-CF 10 amplified detectors.","abstract_has_math":false,"creators":["Adikarige, Chamithri"],"institution":null,"degree_name":"Physics (MS)","degree_level":"Thesis","degree_discipline":"School of Physics and Astronomy (COS)","degree_department":null,"school":null,"contributors":["George M. Thurston"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:04:53Z","subjects":["None provided"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/11075","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/11075","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-12200","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["George M. Thurston"]},{"key":"dc:creator","label":"Author","values":["Adikarige, Chamithri"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2022-01-27T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["School of Physics and Astronomy (COS)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Physics (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["None provided"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/11075"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Single photons are vital to quantum computing, information processing, and transportation. Popular single-photon experiments are one or two-photon interference, classification of the light source, and characterization of detectors. Currently, the most efficient detector in the telecom wavelength is the Superconducting Nanowire detector. How- ever, experiments have been successful in demonstrating single-photon measurements can be done with unconventional detectors. One such method employed an EMCCD camera to observe spatial correlations between pixels with single photons. This thesis aims to test non-single photon-counting PIN photodetectors to observe time-correlation measurement. The improved detection model uses a high-resolution 2GHz oscilloscope and a cross-correlation algorithm. Results were compared with coincidence measurements using an SNSPD and TAC module. Previous PIN-related single- photon experiments mainly used PIN avalanche detectors. We aim to accomplish the same task with Thorlabs PDA-CF 10 amplified detectors."]},{"key":"dc:title","label":"Title","values":["Quantum Correlations using Classical Detectors"]}]}],"canonical_facts":{"dc:contributor":["George M. Thurston"],"dc:creator":["Adikarige, Chamithri"],"dc:date.available":["2022-01-27T08:00:00Z"],"dc:date.created":["2021-12-01T08:00:00Z"],"dc:description.abstract":["Single photons are vital to quantum computing, information processing, and transportation. Popular single-photon experiments are one or two-photon interference, classification of the light source, and characterization of detectors. Currently, the most efficient detector in the telecom wavelength is the Superconducting Nanowire detector. How- ever, experiments have been successful in demonstrating single-photon measurements can be done with unconventional detectors. One such method employed an EMCCD camera to observe spatial correlations between pixels with single photons. This thesis aims to test non-single photon-counting PIN photodetectors to observe time-correlation measurement. The improved detection model uses a high-resolution 2GHz oscilloscope and a cross-correlation algorithm. Results were compared with coincidence measurements using an SNSPD and TAC module. Previous PIN-related single- photon experiments mainly used PIN avalanche detectors. We aim to accomplish the same task with Thorlabs PDA-CF 10 amplified detectors."],"dc:identifier":["https://repository.rit.edu/theses/11075"],"dc:subject":["None provided"],"dc:title":["Quantum Correlations using Classical Detectors"],"thesis:degree_discipline":["School of Physics and Astronomy (COS)"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Physics (MS)"]},"updated_at":"2026-11-19T09:04:53Z"}