{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-12435"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-12435","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Comparison of Methane Plume Detection Using Shortwave and Longwave Infrared Hyperspectral Sensors Under Varying Environmental Conditions","abstract":"Methane is a prevalent greenhouse gas with potent heat trapping capabilities, but methane emissions can be difficult to detect and track. Hyperspectral imagery is an effective method of detection which can locate methane emission sources in order to mitigate leaks, as well as provide accountability for reaching emissions reduction goals. Because of methane’s absorption features in the infrared, both shortwave infrared (SWIR) and longwave infrared (LWIR) hyperspectral sensors have been used to accurately detect methane plumes. However, surface, environmental and atmospheric background conditions can cause methane detectability to vary. This study compared methane detectability under varying environmental conditions for two airborne hyperspectral sensors: AVIRIS-NG in the SWIR and HyTES in the LWIR. For this trade study, we modeled methane plume detection under a wide variety of precisely known conditions by making use of synthetic images which were comprised of MODTRAN-generated radiance curves. We applied a matched filter to these images to assess detection accuracy, and used these results to identify the conditions which have the greatest impact on detectability in the SWIR and LWIR: surface reflectance, surface temperature, and water vapor concentration. We then computed the specific boundaries on these conditions which make methane most detectable for each instrument. The results of this trade study can help inform decision making about which sensors are most useful for various types of methane emission analysis, such as leak detection, plume mapping, and emissions rate quantification.","abstract_html":"Methane is a prevalent greenhouse gas with potent heat trapping capabilities, but methane emissions can be difficult to detect and track. Hyperspectral imagery is an effective method of detection which can locate methane emission sources in order to mitigate leaks, as well as provide accountability for reaching emissions reduction goals. Because of methane’s absorption features in the infrared, both shortwave infrared (SWIR) and longwave infrared (LWIR) hyperspectral sensors have been used to accurately detect methane plumes. However, surface, environmental and atmospheric background conditions can cause methane detectability to vary. This study compared methane detectability under varying environmental conditions for two airborne hyperspectral sensors: AVIRIS-NG in the SWIR and HyTES in the LWIR. For this trade study, we modeled methane plume detection under a wide variety of precisely known conditions by making use of synthetic images which were comprised of MODTRAN-generated radiance curves. We applied a matched filter to these images to assess detection accuracy, and used these results to identify the conditions which have the greatest impact on detectability in the SWIR and LWIR: surface reflectance, surface temperature, and water vapor concentration. We then computed the specific boundaries on these conditions which make methane most detectable for each instrument. The results of this trade study can help inform decision making about which sensors are most useful for various types of methane emission analysis, such as leak detection, plume mapping, and emissions rate quantification.","abstract_has_math":false,"creators":["Zimmerman, Lucy"],"institution":null,"degree_name":"Imaging Science (MS)","degree_level":"Thesis","degree_discipline":"Chester F. Carlson Center for Imaging Science (COS)","degree_department":null,"school":null,"contributors":["John Kerekes"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:05:12Z","subjects":["Gas leak detection","Hyperspectral","Longwave infrared","Methane detection","Remote sensing","Shortwave infrared"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/11299","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/11299","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-12435","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["John Kerekes"]},{"key":"dc:creator","label":"Author","values":["Zimmerman, Lucy"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2022-09-30T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-09-07T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chester F. Carlson Center for Imaging Science (COS)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Imaging Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Gas leak detection","Hyperspectral","Longwave infrared","Methane detection","Remote sensing","Shortwave infrared"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/11299"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Methane is a prevalent greenhouse gas with potent heat trapping capabilities, but methane emissions can be difficult to detect and track. Hyperspectral imagery is an effective method of detection which can locate methane emission sources in order to mitigate leaks, as well as provide accountability for reaching emissions reduction goals. Because of methane’s absorption features in the infrared, both shortwave infrared (SWIR) and longwave infrared (LWIR) hyperspectral sensors have been used to accurately detect methane plumes. However, surface, environmental and atmospheric background conditions can cause methane detectability to vary. This study compared methane detectability under varying environmental conditions for two airborne hyperspectral sensors: AVIRIS-NG in the SWIR and HyTES in the LWIR. For this trade study, we modeled methane plume detection under a wide variety of precisely known conditions by making use of synthetic images which were comprised of MODTRAN-generated radiance curves. We applied a matched filter to these images to assess detection accuracy, and used these results to identify the conditions which have the greatest impact on detectability in the SWIR and LWIR: surface reflectance, surface temperature, and water vapor concentration. We then computed the specific boundaries on these conditions which make methane most detectable for each instrument. The results of this trade study can help inform decision making about which sensors are most useful for various types of methane emission analysis, such as leak detection, plume mapping, and emissions rate quantification."]},{"key":"dc:title","label":"Title","values":["Comparison of Methane Plume Detection Using Shortwave and Longwave Infrared Hyperspectral Sensors Under Varying Environmental Conditions"]}]}],"canonical_facts":{"dc:contributor":["John Kerekes"],"dc:creator":["Zimmerman, Lucy"],"dc:date.available":["2022-09-30T07:00:00Z"],"dc:date.created":["2022-09-07T07:00:00Z"],"dc:description.abstract":["Methane is a prevalent greenhouse gas with potent heat trapping capabilities, but methane emissions can be difficult to detect and track. Hyperspectral imagery is an effective method of detection which can locate methane emission sources in order to mitigate leaks, as well as provide accountability for reaching emissions reduction goals. Because of methane’s absorption features in the infrared, both shortwave infrared (SWIR) and longwave infrared (LWIR) hyperspectral sensors have been used to accurately detect methane plumes. However, surface, environmental and atmospheric background conditions can cause methane detectability to vary. This study compared methane detectability under varying environmental conditions for two airborne hyperspectral sensors: AVIRIS-NG in the SWIR and HyTES in the LWIR. For this trade study, we modeled methane plume detection under a wide variety of precisely known conditions by making use of synthetic images which were comprised of MODTRAN-generated radiance curves. We applied a matched filter to these images to assess detection accuracy, and used these results to identify the conditions which have the greatest impact on detectability in the SWIR and LWIR: surface reflectance, surface temperature, and water vapor concentration. We then computed the specific boundaries on these conditions which make methane most detectable for each instrument. The results of this trade study can help inform decision making about which sensors are most useful for various types of methane emission analysis, such as leak detection, plume mapping, and emissions rate quantification."],"dc:identifier":["https://repository.rit.edu/theses/11299"],"dc:subject":["Gas leak detection","Hyperspectral","Longwave infrared","Methane detection","Remote sensing","Shortwave infrared"],"dc:title":["Comparison of Methane Plume Detection Using Shortwave and Longwave Infrared Hyperspectral Sensors Under Varying Environmental Conditions"],"thesis:degree_discipline":["Chester F. Carlson Center for Imaging Science (COS)"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Imaging Science (MS)"]},"updated_at":"2026-11-19T09:05:12Z"}