{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-13047"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-13047","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Photonic Integrated Circuit Data Acquisition and Tunable Laser Control for Biomedical Point of Care Systems","abstract":"In the world of healthcare, it has always been desirable to have a single test that can screen for multiple different patient ailments at once. Toward this end, a silicon photonics platform has been developed that uses photonic integrated circuits in combination with lasers to simultaneously perform various biological assays, i.e., to screen for biological markers in a patient’s sample. This system uses inexpensive passive flow cards with inexpensive photonic integrated circuits to create a disposable test platform that can be used in point of care environments. However, the necessary bench-top equipment to run an assay with these cards is currently cost prohibitive for point of care applications. In this work, an alternative, custom, low-cost system tailored to the specific needs of this platform has been developed. This system, also called the reader, is able to drive and control various tunable laser sources and read data from photodiodes, which capture radiation power levels at the output of the optical system. The photo generated currents are then amplified in an analog front end, digitized using a microcontroller embedded analog-to-digital converter, and finally stored and transferred to a host PC for post-processing.","abstract_html":"In the world of healthcare, it has always been desirable to have a single test that can screen for multiple different patient ailments at once. Toward this end, a silicon photonics platform has been developed that uses photonic integrated circuits in combination with lasers to simultaneously perform various biological assays, i.e., to screen for biological markers in a patient’s sample. This system uses inexpensive passive flow cards with inexpensive photonic integrated circuits to create a disposable test platform that can be used in point of care environments. However, the necessary bench-top equipment to run an assay with these cards is currently cost prohibitive for point of care applications. In this work, an alternative, custom, low-cost system tailored to the specific needs of this platform has been developed. This system, also called the reader, is able to drive and control various tunable laser sources and read data from photodiodes, which capture radiation power levels at the output of the optical system. The photo generated currents are then amplified in an analog front end, digitized using a microcontroller embedded analog-to-digital converter, and finally stored and transferred to a host PC for post-processing.","abstract_has_math":false,"creators":["Thoburn, Maximilian"],"institution":null,"degree_name":"Electrical Engineering (MS)","degree_level":"Thesis","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Dorin Patru"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:05:51Z","subjects":["Embedded systems","Microfluidics","Multiplex biosensor","Near-infrared spectroscopy","Ring resonator","Transimpedance amplifier"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/11910","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/11910","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-13047","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dorin Patru"]},{"key":"dc:creator","label":"Author","values":["Thoburn, Maximilian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-03-29T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-08-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Electrical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Embedded systems","Microfluidics","Multiplex biosensor","Near-infrared spectroscopy","Ring resonator","Transimpedance amplifier"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/11910"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In the world of healthcare, it has always been desirable to have a single test that can screen for multiple different patient ailments at once. Toward this end, a silicon photonics platform has been developed that uses photonic integrated circuits in combination with lasers to simultaneously perform various biological assays, i.e., to screen for biological markers in a patient’s sample. This system uses inexpensive passive flow cards with inexpensive photonic integrated circuits to create a disposable test platform that can be used in point of care environments. However, the necessary bench-top equipment to run an assay with these cards is currently cost prohibitive for point of care applications. In this work, an alternative, custom, low-cost system tailored to the specific needs of this platform has been developed. This system, also called the reader, is able to drive and control various tunable laser sources and read data from photodiodes, which capture radiation power levels at the output of the optical system. The photo generated currents are then amplified in an analog front end, digitized using a microcontroller embedded analog-to-digital converter, and finally stored and transferred to a host PC for post-processing."]},{"key":"dc:title","label":"Title","values":["Photonic Integrated Circuit Data Acquisition and Tunable Laser Control for Biomedical Point of Care Systems"]}]}],"canonical_facts":{"dc:contributor":["Dorin Patru"],"dc:creator":["Thoburn, Maximilian"],"dc:date.available":["2025-03-29T07:00:00Z"],"dc:date.created":["2024-08-01T07:00:00Z"],"dc:description.abstract":["In the world of healthcare, it has always been desirable to have a single test that can screen for multiple different patient ailments at once. Toward this end, a silicon photonics platform has been developed that uses photonic integrated circuits in combination with lasers to simultaneously perform various biological assays, i.e., to screen for biological markers in a patient’s sample. This system uses inexpensive passive flow cards with inexpensive photonic integrated circuits to create a disposable test platform that can be used in point of care environments. However, the necessary bench-top equipment to run an assay with these cards is currently cost prohibitive for point of care applications. In this work, an alternative, custom, low-cost system tailored to the specific needs of this platform has been developed. This system, also called the reader, is able to drive and control various tunable laser sources and read data from photodiodes, which capture radiation power levels at the output of the optical system. The photo generated currents are then amplified in an analog front end, digitized using a microcontroller embedded analog-to-digital converter, and finally stored and transferred to a host PC for post-processing."],"dc:identifier":["https://repository.rit.edu/theses/11910"],"dc:subject":["Embedded systems","Microfluidics","Multiplex biosensor","Near-infrared spectroscopy","Ring resonator","Transimpedance amplifier"],"dc:title":["Photonic Integrated Circuit Data Acquisition and Tunable Laser Control for Biomedical Point of Care Systems"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Electrical Engineering (MS)"]},"updated_at":"2026-11-19T09:05:51Z"}