{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-13911"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-13911","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Semiconductor Laser Calibration Through Photonic Chip with Microcontroller Driven Wavelength Inference","abstract":"Integrated Silicon Photonics leverages light-speed operation with lower power and higher data rates than electronic counterparts. To achieve this, light is sent through a silicon circuit, where it is manipulated to perform various operations. Primarily, the light for these circuits comes from laser sources. Semiconductor lasers are typically used for their small form factor and ability to be heterogeneously integrated into larger, more complex systems. Because the optical phase and wavelength of light respond to minute changes in local refractive index, light is increasingly used for high-sensitivity sensing in integrated photonic circuit applications. As such, schemes that integrate the laser into larger integrated photonic systems would enable inline monitoring across a wide array of applications in sensor fields, such as biological sensing. In the general sense, some form of biosensor requires wavelength sweeps to detect a change and correlate it with a biological process occurring within the circuit/system. To achieve smooth, linear wavelength sweeps, laser sources need to be calibrated over a specified range. A typical integrated laser source configuration is a distributed bragg reflector (DBR), which uses two different structures to control the output wavelength. Both the phase current, controlling the cavity's phase, and the grating current, which controls the filter, are the wavelength control variables. Calibration requires finding the correct combination of grating and phase currents to traverse the 2-dimensional wavelength space. Measuring the wavelength of a laser source is typically not trivial, and an expensive lab-grade wavemeter is required. In this thesis, an alternative that uses an integrated photonic circuit to extract the laser wavelength was developed, and furthermore, a calibration algorithm is demonstrated that works with both cases: (i) the lab-grade wavemeter instrument and (ii) the photonic integrated circuit implementation of a wavemeter to deliver laser calibration with a custom laser driver and a custom-made data collection system.","abstract_html":"Integrated Silicon Photonics leverages light-speed operation with lower power and higher data rates than electronic counterparts. To achieve this, light is sent through a silicon circuit, where it is manipulated to perform various operations. Primarily, the light for these circuits comes from laser sources. Semiconductor lasers are typically used for their small form factor and ability to be heterogeneously integrated into larger, more complex systems. Because the optical phase and wavelength of light respond to minute changes in local refractive index, light is increasingly used for high-sensitivity sensing in integrated photonic circuit applications. As such, schemes that integrate the laser into larger integrated photonic systems would enable inline monitoring across a wide array of applications in sensor fields, such as biological sensing. In the general sense, some form of biosensor requires wavelength sweeps to detect a change and correlate it with a biological process occurring within the circuit/system. To achieve smooth, linear wavelength sweeps, laser sources need to be calibrated over a specified range. A typical integrated laser source configuration is a distributed bragg reflector (DBR), which uses two different structures to control the output wavelength. Both the phase current, controlling the cavity&#x27;s phase, and the grating current, which controls the filter, are the wavelength control variables. Calibration requires finding the correct combination of grating and phase currents to traverse the 2-dimensional wavelength space. Measuring the wavelength of a laser source is typically not trivial, and an expensive lab-grade wavemeter is required. In this thesis, an alternative that uses an integrated photonic circuit to extract the laser wavelength was developed, and furthermore, a calibration algorithm is demonstrated that works with both cases: (i) the lab-grade wavemeter instrument and (ii) the photonic integrated circuit implementation of a wavemeter to deliver laser calibration with a custom laser driver and a custom-made data collection system.","abstract_has_math":false,"creators":["Acheson, Clayton"],"institution":null,"degree_name":"Computer Engineering (MS)","degree_level":"Thesis","degree_discipline":"Computer Engineering","degree_department":null,"school":null,"contributors":["Stefan Preble"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T05:34:17Z","subjects":["AIM Photonics","Photonic Integrated Circuits","Tunable DBR Laser","Tunable Laser Calibration"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/12782","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/12782","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Arit%3Aoai%3Arepository.rit.edu%3Atheses-13911","prefix":"oai_dc"},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-13911","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Stefan Preble"]},{"key":"dc:creator","label":"Author","values":["Acheson, Clayton"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-09-01T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-08-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Computer Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["AIM Photonics","Photonic Integrated Circuits","Tunable DBR Laser","Tunable Laser Calibration"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/12782"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Integrated Silicon Photonics leverages light-speed operation with lower power and higher data rates than electronic counterparts. To achieve this, light is sent through a silicon circuit, where it is manipulated to perform various operations. Primarily, the light for these circuits comes from laser sources. Semiconductor lasers are typically used for their small form factor and ability to be heterogeneously integrated into larger, more complex systems. Because the optical phase and wavelength of light respond to minute changes in local refractive index, light is increasingly used for high-sensitivity sensing in integrated photonic circuit applications. As such, schemes that integrate the laser into larger integrated photonic systems would enable inline monitoring across a wide array of applications in sensor fields, such as biological sensing. In the general sense, some form of biosensor requires wavelength sweeps to detect a change and correlate it with a biological process occurring within the circuit/system. To achieve smooth, linear wavelength sweeps, laser sources need to be calibrated over a specified range. A typical integrated laser source configuration is a distributed bragg reflector (DBR), which uses two different structures to control the output wavelength. Both the phase current, controlling the cavity's phase, and the grating current, which controls the filter, are the wavelength control variables. Calibration requires finding the correct combination of grating and phase currents to traverse the 2-dimensional wavelength space. Measuring the wavelength of a laser source is typically not trivial, and an expensive lab-grade wavemeter is required. In this thesis, an alternative that uses an integrated photonic circuit to extract the laser wavelength was developed, and furthermore, a calibration algorithm is demonstrated that works with both cases: (i) the lab-grade wavemeter instrument and (ii) the photonic integrated circuit implementation of a wavemeter to deliver laser calibration with a custom laser driver and a custom-made data collection system."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>This thesis has been embargoed. The full-text will be available on or around 8/13/2027.</p>"]},{"key":"dc:title","label":"Title","values":["Semiconductor Laser Calibration Through Photonic Chip with Microcontroller Driven Wavelength Inference"]}]}],"canonical_facts":{"dc:contributor":["Stefan Preble"],"dc:creator":["Acheson, Clayton"],"dc:date.available":["2026-09-01T07:00:00Z"],"dc:date.created":["2026-08-01T07:00:00Z"],"dc:description.abstract":["Integrated Silicon Photonics leverages light-speed operation with lower power and higher data rates than electronic counterparts. To achieve this, light is sent through a silicon circuit, where it is manipulated to perform various operations. Primarily, the light for these circuits comes from laser sources. Semiconductor lasers are typically used for their small form factor and ability to be heterogeneously integrated into larger, more complex systems. Because the optical phase and wavelength of light respond to minute changes in local refractive index, light is increasingly used for high-sensitivity sensing in integrated photonic circuit applications. As such, schemes that integrate the laser into larger integrated photonic systems would enable inline monitoring across a wide array of applications in sensor fields, such as biological sensing. In the general sense, some form of biosensor requires wavelength sweeps to detect a change and correlate it with a biological process occurring within the circuit/system. To achieve smooth, linear wavelength sweeps, laser sources need to be calibrated over a specified range. A typical integrated laser source configuration is a distributed bragg reflector (DBR), which uses two different structures to control the output wavelength. Both the phase current, controlling the cavity's phase, and the grating current, which controls the filter, are the wavelength control variables. Calibration requires finding the correct combination of grating and phase currents to traverse the 2-dimensional wavelength space. Measuring the wavelength of a laser source is typically not trivial, and an expensive lab-grade wavemeter is required. In this thesis, an alternative that uses an integrated photonic circuit to extract the laser wavelength was developed, and furthermore, a calibration algorithm is demonstrated that works with both cases: (i) the lab-grade wavemeter instrument and (ii) the photonic integrated circuit implementation of a wavemeter to deliver laser calibration with a custom laser driver and a custom-made data collection system."],"dc:description.note":["<p>This thesis has been embargoed. The full-text will be available on or around 8/13/2027.</p>"],"dc:identifier":["https://repository.rit.edu/theses/12782"],"dc:subject":["AIM Photonics","Photonic Integrated Circuits","Tunable DBR Laser","Tunable Laser Calibration"],"dc:title":["Semiconductor Laser Calibration Through Photonic Chip with Microcontroller Driven Wavelength Inference"],"thesis:degree_discipline":["Computer Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Computer Engineering (MS)"]},"updated_at":"2026-11-27T05:34:17Z"}