{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-3986"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-3986","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Application of imaging system geometric models to a synthetic image generation system","abstract":"A generalized imaging system geometric model has been incorporated into the Center for Imaging Science Digital Imaging and Remote Sensing Image Generation (DIRSIG) software system. The camera model is capable of simulating the geometric characteristics of frame cameras, line scanners and pushbroom scanners. The user of the model has the ability to define both the sensor internal orientation as well as provide time varying external orientation parameters. The model has been successfully validated through the use of both diagnostic simulated scenes as well as quantitative comparisons between actual imagery and simulated imagery.","abstract_html":"A generalized imaging system geometric model has been incorporated into the Center for Imaging Science Digital Imaging and Remote Sensing Image Generation (DIRSIG) software system. The camera model is capable of simulating the geometric characteristics of frame cameras, line scanners and pushbroom scanners. The user of the model has the ability to define both the sensor internal orientation as well as provide time varying external orientation parameters. The model has been successfully validated through the use of both diagnostic simulated scenes as well as quantitative comparisons between actual imagery and simulated imagery.","abstract_has_math":false,"creators":["Salacain, James M."],"institution":null,"degree_name":"Imaging Science (MS)","degree_level":"Thesis","degree_discipline":"Chester F. Carlson Center for Imaging Science (COS)","degree_department":null,"school":null,"contributors":["Schott, John"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:00:33Z","subjects":["Imaging science"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/2982","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/2982","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-3986","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Schott, John"]},{"key":"dc:creator","label":"Author","values":["Salacain, James M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1995-03-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chester F. Carlson Center for Imaging Science (COS)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Imaging Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Imaging science"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/2982"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A generalized imaging system geometric model has been incorporated into the Center for Imaging Science Digital Imaging and Remote Sensing Image Generation (DIRSIG) software system. The camera model is capable of simulating the geometric characteristics of frame cameras, line scanners and pushbroom scanners. The user of the model has the ability to define both the sensor internal orientation as well as provide time varying external orientation parameters. The model has been successfully validated through the use of both diagnostic simulated scenes as well as quantitative comparisons between actual imagery and simulated imagery."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>Note: imported from RIT’s Digital Media Library running on DSpace to RIT Scholar Works. Physical copy available through RIT's The Wallace Library at: TR693 .S24 1995</p>"]},{"key":"dc:title","label":"Title","values":["Application of imaging system geometric models to a synthetic image generation system"]}]}],"canonical_facts":{"dc:contributor":["Schott, John"],"dc:creator":["Salacain, James M."],"dc:date.created":["1995-03-01T08:00:00Z"],"dc:description.abstract":["A generalized imaging system geometric model has been incorporated into the Center for Imaging Science Digital Imaging and Remote Sensing Image Generation (DIRSIG) software system. The camera model is capable of simulating the geometric characteristics of frame cameras, line scanners and pushbroom scanners. The user of the model has the ability to define both the sensor internal orientation as well as provide time varying external orientation parameters. The model has been successfully validated through the use of both diagnostic simulated scenes as well as quantitative comparisons between actual imagery and simulated imagery."],"dc:description.note":["<p>Note: imported from RIT’s Digital Media Library running on DSpace to RIT Scholar Works. Physical copy available through RIT's The Wallace Library at: TR693 .S24 1995</p>"],"dc:identifier":["https://repository.rit.edu/theses/2982"],"dc:subject":["Imaging science"],"dc:title":["Application of imaging system geometric models to a synthetic image generation system"],"thesis:degree_discipline":["Chester F. Carlson Center for Imaging Science (COS)"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Imaging Science (MS)"]},"updated_at":"2026-11-19T09:00:33Z"}