{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-7748"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-7748","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Increasing Visual Detectability in Reduced Exposure Mammography by Contrast Adjustment","abstract":"The radiobiologic level from an average direct-exposure, fine-grain mammograph approaches 4000 millirads. Copying reduced-exposure mammographs onto high gradient films yields a method of reducing radiation to the patient by a factor of 2. A mathematically based tone-reproduction system was developed in an attempt to produce acceptable facsimile images from a series of reduced-exposure mammographs. Acceptability was tested by radiologists using a sensitometric phantum. The radiologists were asked to quality rank a full exposure mammograph, facsimile mammographs, and a film-screen mammograph in terms of detectability of size and number of calcifications. Based on evidence, there is reason to believe that a facsimile mammograph produced with 50 percent normal radiation is diagnostically equivalent to a film/screen mammograph. However, even with this reduction in photographic and radiobiologic exposure, film/screen combination mammographs result in approximately 500 millirads, thus making them superior in terms of patient irradiation.","abstract_html":"The radiobiologic level from an average direct-exposure, fine-grain mammograph approaches 4000 millirads. Copying reduced-exposure mammographs onto high gradient films yields a method of reducing radiation to the patient by a factor of 2. A mathematically based tone-reproduction system was developed in an attempt to produce acceptable facsimile images from a series of reduced-exposure mammographs. Acceptability was tested by radiologists using a sensitometric phantum. The radiologists were asked to quality rank a full exposure mammograph, facsimile mammographs, and a film-screen mammograph in terms of detectability of size and number of calcifications. Based on evidence, there is reason to believe that a facsimile mammograph produced with 50 percent normal radiation is diagnostically equivalent to a film/screen mammograph. However, even with this reduction in photographic and radiobiologic exposure, film/screen combination mammographs result in approximately 500 millirads, thus making them superior in terms of patient irradiation.","abstract_has_math":false,"creators":["Richer, Stuart"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":"School of Photographic Arts and Sciences (CIAS)","degree_department":null,"school":null,"contributors":["Schumann, Gerhard"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:00:54Z","subjects":["Breast cancer detection","Mammography","Photographic arts and sciences","Senior research project"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/6743","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/6743","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-7748","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Schumann, Gerhard"]},{"key":"dc:creator","label":"Author","values":["Richer, Stuart"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1977-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["School of Photographic Arts and Sciences (CIAS)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Breast cancer detection","Mammography","Photographic arts and sciences","Senior research project"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/6743"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The radiobiologic level from an average direct-exposure, fine-grain mammograph approaches 4000 millirads. Copying reduced-exposure mammographs onto high gradient films yields a method of reducing radiation to the patient by a factor of 2. A mathematically based tone-reproduction system was developed in an attempt to produce acceptable facsimile images from a series of reduced-exposure mammographs. Acceptability was tested by radiologists using a sensitometric phantum. The radiologists were asked to quality rank a full exposure mammograph, facsimile mammographs, and a film-screen mammograph in terms of detectability of size and number of calcifications. Based on evidence, there is reason to believe that a facsimile mammograph produced with 50 percent normal radiation is diagnostically equivalent to a film/screen mammograph. However, even with this reduction in photographic and radiobiologic exposure, film/screen combination mammographs result in approximately 500 millirads, thus making them superior in terms of patient irradiation."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>Note: imported from RIT’s Digital Media Library running on DSpace to RIT Scholar Works in February 2014. Physical copy available through RIT's The Wallace Library at: RJ496.I6 D46 2009</p>"]},{"key":"dc:title","label":"Title","values":["Increasing Visual Detectability in Reduced Exposure Mammography by Contrast Adjustment"]}]}],"canonical_facts":{"dc:contributor":["Schumann, Gerhard"],"dc:creator":["Richer, Stuart"],"dc:date.created":["1977-01-01T08:00:00Z"],"dc:description.abstract":["The radiobiologic level from an average direct-exposure, fine-grain mammograph approaches 4000 millirads. Copying reduced-exposure mammographs onto high gradient films yields a method of reducing radiation to the patient by a factor of 2. A mathematically based tone-reproduction system was developed in an attempt to produce acceptable facsimile images from a series of reduced-exposure mammographs. Acceptability was tested by radiologists using a sensitometric phantum. The radiologists were asked to quality rank a full exposure mammograph, facsimile mammographs, and a film-screen mammograph in terms of detectability of size and number of calcifications. Based on evidence, there is reason to believe that a facsimile mammograph produced with 50 percent normal radiation is diagnostically equivalent to a film/screen mammograph. However, even with this reduction in photographic and radiobiologic exposure, film/screen combination mammographs result in approximately 500 millirads, thus making them superior in terms of patient irradiation."],"dc:description.note":["<p>Note: imported from RIT’s Digital Media Library running on DSpace to RIT Scholar Works in February 2014. Physical copy available through RIT's The Wallace Library at: RJ496.I6 D46 2009</p>"],"dc:identifier":["https://repository.rit.edu/theses/6743"],"dc:subject":["Breast cancer detection","Mammography","Photographic arts and sciences","Senior research project"],"dc:title":["Increasing Visual Detectability in Reduced Exposure Mammography by Contrast Adjustment"],"thesis:degree_discipline":["School of Photographic Arts and Sciences (CIAS)"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-19T09:00:54Z"}