{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-9359"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-9359","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Modeling, Simulation and Fabrication of 100 nm (Leff) High Performance CMOS Transistors","abstract":"A 100 nm CMOS process is modeled and simulated using advanced ion implantation, diffusion models, recombination and mobility models; in ATHENA and ATLAS respectively. This process is designed for a mask length of 150 nm and effective gate length of = The drive current on modeled and simulated device for NMOS and PMOS are 300 µA/µm and 63 µA/µm at 1.2 V drain and gate bias respectively. The threshold voltage for the modeled NMOS and PMOS is 0.479 V and -0.58 V with DIBL less than 12 mV/V on both the devices. Unit process improvements includes retrograde well doping to reduce short channel effects, double exposure to obtain minimum feature size, anisotropic polysilicon and nitride spacers etch, high dose source drain extension implants to minimize the contribution of parasitic resistance to ON state performance of the device, high dose source drain implants followed by SALICIDE process to provide ohmic contacts. Fabricated devices failed because of excessive gate leakage.","abstract_html":"A 100 nm CMOS process is modeled and simulated using advanced ion implantation, diffusion models, recombination and mobility models; in ATHENA and ATLAS respectively. This process is designed for a mask length of 150 nm and effective gate length of = The drive current on modeled and simulated device for NMOS and PMOS are 300 µA/µm and 63 µA/µm at 1.2 V drain and gate bias respectively. The threshold voltage for the modeled NMOS and PMOS is 0.479 V and -0.58 V with DIBL less than 12 mV/V on both the devices. Unit process improvements includes retrograde well doping to reduce short channel effects, double exposure to obtain minimum feature size, anisotropic polysilicon and nitride spacers etch, high dose source drain extension implants to minimize the contribution of parasitic resistance to ON state performance of the device, high dose source drain implants followed by SALICIDE process to provide ohmic contacts. Fabricated devices failed because of excessive gate leakage.","abstract_has_math":false,"creators":["Amareshbabu, Chandan K"],"institution":null,"degree_name":"Electrical Engineering (MS)","degree_level":"Thesis","degree_discipline":"Electrical Engineering (KGCOE)","degree_department":null,"school":null,"contributors":["Lynn F. Fuller"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:01:41Z","subjects":["Fabrication","Diffusion","Doping concentration","Lithography","Metals","Dry etch"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/8334","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/8334","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-9359","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Lynn F. Fuller"]},{"key":"dc:creator","label":"Author","values":["Amareshbabu, Chandan K"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["1970-01-01T11:38:07Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-08-14T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering (KGCOE)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Electrical Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fabrication","Diffusion","Doping concentration","Lithography","Metals","Dry etch"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/8334"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A 100 nm CMOS process is modeled and simulated using advanced ion implantation, diffusion models, recombination and mobility models; in ATHENA and ATLAS respectively. This process is designed for a mask length of 150 nm and effective gate length of = The drive current on modeled and simulated device for NMOS and PMOS are 300 µA/µm and 63 µA/µm at 1.2 V drain and gate bias respectively. The threshold voltage for the modeled NMOS and PMOS is 0.479 V and -0.58 V with DIBL less than 12 mV/V on both the devices. Unit process improvements includes retrograde well doping to reduce short channel effects, double exposure to obtain minimum feature size, anisotropic polysilicon and nitride spacers etch, high dose source drain extension implants to minimize the contribution of parasitic resistance to ON state performance of the device, high dose source drain implants followed by SALICIDE process to provide ohmic contacts. Fabricated devices failed because of excessive gate leakage."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>Physical copy available from RIT's Wallace Library at TK7871.99.M44 A63 2014</p>"]},{"key":"dc:title","label":"Title","values":["Modeling, Simulation and Fabrication of 100 nm (Leff) High Performance CMOS Transistors"]}]}],"canonical_facts":{"dc:contributor":["Lynn F. Fuller"],"dc:creator":["Amareshbabu, Chandan K"],"dc:date.available":["1970-01-01T11:38:07Z"],"dc:date.created":["2014-08-14T07:00:00Z"],"dc:description.abstract":["A 100 nm CMOS process is modeled and simulated using advanced ion implantation, diffusion models, recombination and mobility models; in ATHENA and ATLAS respectively. This process is designed for a mask length of 150 nm and effective gate length of = The drive current on modeled and simulated device for NMOS and PMOS are 300 µA/µm and 63 µA/µm at 1.2 V drain and gate bias respectively. The threshold voltage for the modeled NMOS and PMOS is 0.479 V and -0.58 V with DIBL less than 12 mV/V on both the devices. Unit process improvements includes retrograde well doping to reduce short channel effects, double exposure to obtain minimum feature size, anisotropic polysilicon and nitride spacers etch, high dose source drain extension implants to minimize the contribution of parasitic resistance to ON state performance of the device, high dose source drain implants followed by SALICIDE process to provide ohmic contacts. Fabricated devices failed because of excessive gate leakage."],"dc:description.note":["<p>Physical copy available from RIT's Wallace Library at TK7871.99.M44 A63 2014</p>"],"dc:identifier":["https://repository.rit.edu/theses/8334"],"dc:subject":["Fabrication","Diffusion","Doping concentration","Lithography","Metals","Dry etch"],"dc:title":["Modeling, Simulation and Fabrication of 100 nm (Leff) High Performance CMOS Transistors"],"thesis:degree_discipline":["Electrical Engineering (KGCOE)"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Electrical Engineering (MS)"]},"updated_at":"2026-11-19T09:01:41Z"}