{"id":{"repo_id":"rit","oai_identifier":"oai:repository.rit.edu:theses-9360"},"canonical_url":"https://search.ndltd.org/etd/rit/oai:repository.rit.edu:theses-9360","repository":{"repo_id":"rit","name":"Rochester Institute of Technology","base_url":"https://repository.rit.edu/do/oai/"},"display":{"title":"Using Least Variance for Robust Extraction of Systolic Time Intervals","abstract":"Systolic time intervals (STI) are clinically used as non-invasive predictor of cardiovascular disease. However, algorithm accuracy generally suffers across subjects and physiological states, requiring parameter tuning for robust STI extraction. To address this challenge, an automated methodology of processing with varying tuning parameters was explored. In this work, two STIs were examined: the R-wave pulse transit time to the PPG foot at the ear (rPTT) and the left ventricular ejection time (LVET). Historic feature detection algorithms were used with a range of tuning parameters over a 60 second interval, with least variance used to select the optimal parameter for robust extraction. These least variance algorithms were quantitatively compared to historic, single parameter algorithms using a positive predictive value metric. In order to decrease the runtime of the algorithms, the least variance algorithms were written such that they could run on a GPU using CUDA. Overall, the least variance algorithms were able to extract the features better than the historic algorithms, without sacrificing runtime. In addition to providing this robust and reliable STI extraction, the least variance algorithms can be adapted to extract features from any period data stream.","abstract_html":"Systolic time intervals (STI) are clinically used as non-invasive predictor of cardiovascular disease. However, algorithm accuracy generally suffers across subjects and physiological states, requiring parameter tuning for robust STI extraction. To address this challenge, an automated methodology of processing with varying tuning parameters was explored. In this work, two STIs were examined: the R-wave pulse transit time to the PPG foot at the ear (rPTT) and the left ventricular ejection time (LVET). Historic feature detection algorithms were used with a range of tuning parameters over a 60 second interval, with least variance used to select the optimal parameter for robust extraction. These least variance algorithms were quantitatively compared to historic, single parameter algorithms using a positive predictive value metric. In order to decrease the runtime of the algorithms, the least variance algorithms were written such that they could run on a GPU using CUDA. Overall, the least variance algorithms were able to extract the features better than the historic algorithms, without sacrificing runtime. In addition to providing this robust and reliable STI extraction, the least variance algorithms can be adapted to extract features from any period data stream.","abstract_has_math":false,"creators":["Cziesler, Cody R"],"institution":null,"degree_name":"Computer Engineering (MS)","degree_level":"Thesis","degree_discipline":"Microsystems Engineering (KGCOE)","degree_department":null,"school":null,"contributors":["David A. Borkholder"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:01:41Z","subjects":["Biomedical signal processing","Least variance","Left ventricular ejection time","Pulse transit time","Systolic time intervals"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.rit.edu/theses/8333","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.rit.edu/theses/8333","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.rit.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.rit.edu%3Atheses-9360","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["David A. Borkholder"]},{"key":"dc:creator","label":"Author","values":["Cziesler, Cody R"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["1970-01-01T11:38:07Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-05-21T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Microsystems Engineering (KGCOE)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Computer Engineering (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical signal processing","Least variance","Left ventricular ejection time","Pulse transit time","Systolic time intervals"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.rit.edu/theses/8333"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Systolic time intervals (STI) are clinically used as non-invasive predictor of cardiovascular disease. However, algorithm accuracy generally suffers across subjects and physiological states, requiring parameter tuning for robust STI extraction. To address this challenge, an automated methodology of processing with varying tuning parameters was explored. In this work, two STIs were examined: the R-wave pulse transit time to the PPG foot at the ear (rPTT) and the left ventricular ejection time (LVET). Historic feature detection algorithms were used with a range of tuning parameters over a 60 second interval, with least variance used to select the optimal parameter for robust extraction. These least variance algorithms were quantitatively compared to historic, single parameter algorithms using a positive predictive value metric. In order to decrease the runtime of the algorithms, the least variance algorithms were written such that they could run on a GPU using CUDA. Overall, the least variance algorithms were able to extract the features better than the historic algorithms, without sacrificing runtime. In addition to providing this robust and reliable STI extraction, the least variance algorithms can be adapted to extract features from any period data stream."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>Physical copy available from RIT's Wallace Library at RC681 .C94 2014</p>"]},{"key":"dc:title","label":"Title","values":["Using Least Variance for Robust Extraction of Systolic Time Intervals"]}]}],"canonical_facts":{"dc:contributor":["David A. Borkholder"],"dc:creator":["Cziesler, Cody R"],"dc:date.available":["1970-01-01T11:38:07Z"],"dc:date.created":["2014-05-21T07:00:00Z"],"dc:description.abstract":["Systolic time intervals (STI) are clinically used as non-invasive predictor of cardiovascular disease. However, algorithm accuracy generally suffers across subjects and physiological states, requiring parameter tuning for robust STI extraction. To address this challenge, an automated methodology of processing with varying tuning parameters was explored. In this work, two STIs were examined: the R-wave pulse transit time to the PPG foot at the ear (rPTT) and the left ventricular ejection time (LVET). Historic feature detection algorithms were used with a range of tuning parameters over a 60 second interval, with least variance used to select the optimal parameter for robust extraction. These least variance algorithms were quantitatively compared to historic, single parameter algorithms using a positive predictive value metric. In order to decrease the runtime of the algorithms, the least variance algorithms were written such that they could run on a GPU using CUDA. Overall, the least variance algorithms were able to extract the features better than the historic algorithms, without sacrificing runtime. In addition to providing this robust and reliable STI extraction, the least variance algorithms can be adapted to extract features from any period data stream."],"dc:description.note":["<p>Physical copy available from RIT's Wallace Library at RC681 .C94 2014</p>"],"dc:identifier":["https://repository.rit.edu/theses/8333"],"dc:subject":["Biomedical signal processing","Least variance","Left ventricular ejection time","Pulse transit time","Systolic time intervals"],"dc:title":["Using Least Variance for Robust Extraction of Systolic Time Intervals"],"thesis:degree_discipline":["Microsystems Engineering (KGCOE)"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Computer Engineering (MS)"]},"updated_at":"2026-11-19T09:01:41Z"}