{"id":{"repo_id":"rowan","oai_identifier":"oai:rdw.rowan.edu:etd-3456"},"canonical_url":"https://search.ndltd.org/etd/rowan/oai:rdw.rowan.edu:etd-3456","repository":{"repo_id":"rowan","name":"Rowan University","base_url":"https://rdw.rowan.edu/do/oai/"},"display":{"title":"High throughput analysis of the penetration of iron oxide/polyethylene glycol nanoparticles into multicellular breast cancer tumor spheroids","abstract":"The purpose of this study was to design and optimize a system for the high-throughput analysis of multicellular tumor spheroids (MCTS), and validate the system through the study of a complex biological model. The system was successfully created and optimized, allowing the histological recovery of MCTS at rates up to 90% for microarrays of 24-spheroids. Arrays of 96-spheroids were recovered at rates up to 86%. The system was used to study the penetration of 5k Da-polyethylene coated superparamagnetic iron-oxide nanoparticles (5k-PEG SPIONs) into HTB-126 breast cancer spheroids cultured to a mean diameter of 486 micrometer (± 25.2 micrometer). Results were compared to an identical study using 2D cultures. Positive staining for the SPION dosage of 100 microgram/milliliter in 2D culture regardless of incubation time was observed along with a lack of staining for all other concentrations in both 2D and 3D. SPION incubation led to necrosis in breast cancer spheroids after 3 days.","abstract_html":"The purpose of this study was to design and optimize a system for the high-throughput analysis of multicellular tumor spheroids (MCTS), and validate the system through the study of a complex biological model. The system was successfully created and optimized, allowing the histological recovery of MCTS at rates up to 90% for microarrays of 24-spheroids. Arrays of 96-spheroids were recovered at rates up to 86%. The system was used to study the penetration of 5k Da-polyethylene coated superparamagnetic iron-oxide nanoparticles (5k-PEG SPIONs) into HTB-126 breast cancer spheroids cultured to a mean diameter of 486 micrometer (± 25.2 micrometer). Results were compared to an identical study using 2D cultures. Positive staining for the SPION dosage of 100 microgram/milliliter in 2D culture regardless of incubation time was observed along with a lack of staining for all other concentrations in both 2D and 3D. SPION incubation led to necrosis in breast cancer spheroids after 3 days.","abstract_has_math":false,"creators":["Gabriel, Jonathan Robert"],"institution":null,"degree_name":"MS Mechanical Engineering","degree_level":"Thesis","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Beachley, Vince","Merrill, Thomas","Vernengo, Andrea J."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:58:45Z","subjects":["cancer","diagnostics","high-throughput","multicellular","spheroid","tumor","Cancer--Treatment","Tumors--Analysis","Cell culture","Biomedical Engineering and Bioengineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://rdw.rowan.edu/etd/2454","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://rdw.rowan.edu/etd/2454","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://rdw.rowan.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ardw.rowan.edu%3Aetd-3456","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Beachley, Vince","Merrill, Thomas","Vernengo, Andrea J."]},{"key":"dc:creator","label":"Author","values":["Gabriel, Jonathan Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2018-07-18T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-07-18T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS Mechanical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["cancer","diagnostics","high-throughput","multicellular","spheroid","tumor","Cancer--Treatment","Tumors--Analysis","Cell culture","Biomedical Engineering and Bioengineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://rdw.rowan.edu/etd/2454"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this study was to design and optimize a system for the high-throughput analysis of multicellular tumor spheroids (MCTS), and validate the system through the study of a complex biological model. The system was successfully created and optimized, allowing the histological recovery of MCTS at rates up to 90% for microarrays of 24-spheroids. Arrays of 96-spheroids were recovered at rates up to 86%. The system was used to study the penetration of 5k Da-polyethylene coated superparamagnetic iron-oxide nanoparticles (5k-PEG SPIONs) into HTB-126 breast cancer spheroids cultured to a mean diameter of 486 micrometer (± 25.2 micrometer). Results were compared to an identical study using 2D cultures. Positive staining for the SPION dosage of 100 microgram/milliliter in 2D culture regardless of incubation time was observed along with a lack of staining for all other concentrations in both 2D and 3D. SPION incubation led to necrosis in breast cancer spheroids after 3 days."]},{"key":"dc:title","label":"Title","values":["High throughput analysis of the penetration of iron oxide/polyethylene glycol nanoparticles into multicellular breast cancer tumor spheroids"]}]}],"canonical_facts":{"dc:contributor":["Beachley, Vince","Merrill, Thomas","Vernengo, Andrea J."],"dc:creator":["Gabriel, Jonathan Robert"],"dc:date.available":["2018-07-18T07:00:00Z"],"dc:date.created":["2017-07-18T07:00:00Z"],"dc:description.abstract":["The purpose of this study was to design and optimize a system for the high-throughput analysis of multicellular tumor spheroids (MCTS), and validate the system through the study of a complex biological model. The system was successfully created and optimized, allowing the histological recovery of MCTS at rates up to 90% for microarrays of 24-spheroids. Arrays of 96-spheroids were recovered at rates up to 86%. The system was used to study the penetration of 5k Da-polyethylene coated superparamagnetic iron-oxide nanoparticles (5k-PEG SPIONs) into HTB-126 breast cancer spheroids cultured to a mean diameter of 486 micrometer (± 25.2 micrometer). Results were compared to an identical study using 2D cultures. Positive staining for the SPION dosage of 100 microgram/milliliter in 2D culture regardless of incubation time was observed along with a lack of staining for all other concentrations in both 2D and 3D. SPION incubation led to necrosis in breast cancer spheroids after 3 days."],"dc:identifier":["https://rdw.rowan.edu/etd/2454"],"dc:subject":["cancer","diagnostics","high-throughput","multicellular","spheroid","tumor","Cancer--Treatment","Tumors--Analysis","Cell culture","Biomedical Engineering and Bioengineering"],"dc:title":["High throughput analysis of the penetration of iron oxide/polyethylene glycol nanoparticles into multicellular breast cancer tumor spheroids"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS Mechanical Engineering"]},"updated_at":"2026-11-19T08:58:45Z"}