{"id":{"repo_id":"rowan","oai_identifier":"oai:rdw.rowan.edu:etd-3663"},"canonical_url":"https://search.ndltd.org/etd/rowan/oai:rdw.rowan.edu:etd-3663","repository":{"repo_id":"rowan","name":"Rowan University","base_url":"https://rdw.rowan.edu/do/oai/"},"display":{"title":"Fabrication of enhanced carbon based biocompatible and biodegradable microelectronic materials derived from lignocellulosic biomass","abstract":"The development of materials capable of harmlessly being broken down and removed from the body is a crucial step towards the development of short-term application electronic biomedical implants. Once developed, these implants, known as bioresorbable electronics, will open a wide array of temporary applications in the field of biomedical implantable devices. Necessary to the operation of bioresorbable electronics within the body is a power source that is similarly biocompatible and biodegradable. To this end, enhanced carbon-based materials and a bio-ionic liquid were developed for the fabrication of a preliminary implantable and bioresorbable battery and tested for functional properties. Electrodes were fabricated from carbonized fibers electrospun from solutions of PEO, Kraft Lignin, and a metal salt. The electrolyte was fabricated from fibers electrospun from solutions of PEO, GelMA, and Choline Acrylate. A complete battery set-up with both the fabricated anode, cathode, and electrolyte was characterized using Chronopotentiometry to obtain a potential value of 1.3 volts at an applied current density 0.71 ÂµA /cm2.","abstract_html":"The development of materials capable of harmlessly being broken down and removed from the body is a crucial step towards the development of short-term application electronic biomedical implants. Once developed, these implants, known as bioresorbable electronics, will open a wide array of temporary applications in the field of biomedical implantable devices. Necessary to the operation of bioresorbable electronics within the body is a power source that is similarly biocompatible and biodegradable. To this end, enhanced carbon-based materials and a bio-ionic liquid were developed for the fabrication of a preliminary implantable and bioresorbable battery and tested for functional properties. Electrodes were fabricated from carbonized fibers electrospun from solutions of PEO, Kraft Lignin, and a metal salt. The electrolyte was fabricated from fibers electrospun from solutions of PEO, GelMA, and Choline Acrylate. A complete battery set-up with both the fabricated anode, cathode, and electrolyte was characterized using Chronopotentiometry to obtain a potential value of 1.3 volts at an applied current density 0.71 ÂµA /cm2.","abstract_has_math":false,"creators":["Hawkins, Harrison Thomas"],"institution":null,"degree_name":"MS Chemical Engineering","degree_level":"Thesis","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Noshadi, Iman","Mugweru, Amos","Beachley, Vince"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:59:05Z","subjects":["Implants, Artificial--Biocompatibility","Biomedical materials","Biomedical Engineering and Bioengineering","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://rdw.rowan.edu/etd/2661","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://rdw.rowan.edu/etd/2661","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://rdw.rowan.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ardw.rowan.edu%3Aetd-3663","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Noshadi, Iman","Mugweru, Amos","Beachley, Vince"]},{"key":"dc:creator","label":"Author","values":["Hawkins, Harrison Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-05-17T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-05-16T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS Chemical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Implants, Artificial--Biocompatibility","Biomedical materials","Biomedical Engineering and Bioengineering","Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://rdw.rowan.edu/etd/2661"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The development of materials capable of harmlessly being broken down and removed from the body is a crucial step towards the development of short-term application electronic biomedical implants. Once developed, these implants, known as bioresorbable electronics, will open a wide array of temporary applications in the field of biomedical implantable devices. Necessary to the operation of bioresorbable electronics within the body is a power source that is similarly biocompatible and biodegradable. To this end, enhanced carbon-based materials and a bio-ionic liquid were developed for the fabrication of a preliminary implantable and bioresorbable battery and tested for functional properties. Electrodes were fabricated from carbonized fibers electrospun from solutions of PEO, Kraft Lignin, and a metal salt. The electrolyte was fabricated from fibers electrospun from solutions of PEO, GelMA, and Choline Acrylate. A complete battery set-up with both the fabricated anode, cathode, and electrolyte was characterized using Chronopotentiometry to obtain a potential value of 1.3 volts at an applied current density 0.71 ÂµA /cm2."]},{"key":"dc:title","label":"Title","values":["Fabrication of enhanced carbon based biocompatible and biodegradable microelectronic materials derived from lignocellulosic biomass"]}]}],"canonical_facts":{"dc:contributor":["Noshadi, Iman","Mugweru, Amos","Beachley, Vince"],"dc:creator":["Hawkins, Harrison Thomas"],"dc:date.available":["2019-05-17T07:00:00Z"],"dc:date.created":["2019-05-16T07:00:00Z"],"dc:description.abstract":["The development of materials capable of harmlessly being broken down and removed from the body is a crucial step towards the development of short-term application electronic biomedical implants. Once developed, these implants, known as bioresorbable electronics, will open a wide array of temporary applications in the field of biomedical implantable devices. Necessary to the operation of bioresorbable electronics within the body is a power source that is similarly biocompatible and biodegradable. To this end, enhanced carbon-based materials and a bio-ionic liquid were developed for the fabrication of a preliminary implantable and bioresorbable battery and tested for functional properties. Electrodes were fabricated from carbonized fibers electrospun from solutions of PEO, Kraft Lignin, and a metal salt. The electrolyte was fabricated from fibers electrospun from solutions of PEO, GelMA, and Choline Acrylate. A complete battery set-up with both the fabricated anode, cathode, and electrolyte was characterized using Chronopotentiometry to obtain a potential value of 1.3 volts at an applied current density 0.71 ÂµA /cm2."],"dc:identifier":["https://rdw.rowan.edu/etd/2661"],"dc:subject":["Implants, Artificial--Biocompatibility","Biomedical materials","Biomedical Engineering and Bioengineering","Chemical Engineering"],"dc:title":["Fabrication of enhanced carbon based biocompatible and biodegradable microelectronic materials derived from lignocellulosic biomass"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS Chemical Engineering"]},"updated_at":"2026-11-19T08:59:05Z"}