{"id":{"repo_id":"rowan","oai_identifier":"oai:rdw.rowan.edu:etd-4136"},"canonical_url":"https://search.ndltd.org/etd/rowan/oai:rdw.rowan.edu:etd-4136","repository":{"repo_id":"rowan","name":"Rowan University","base_url":"https://rdw.rowan.edu/do/oai/"},"display":{"title":"CHEMICAL AND POLYMER CHARACTERIZATION OF THE POTENTIAL MODES OF DEGRADATION OF AN INJECTABLE NUCLEUS PULPOSUS REPLACEMENT DEVICE","abstract":"HYDRAFIL™ is a poly(vinyl alcohol)/poly(ethylene glycol)-based hydrogel nucleus pulposus replacement device that is injected in situ and has demonstrated efficacy in lowering the prevalence and pain associated with back. In this work, we developed a method to analyze HYDRAFIL™ polymer composition using (TGA) and characterized intermolecular bonding interactions within the hydrogel through (FTIR). To function as a permanent implant for nucleus pulposus replacement, HYDRAFIL™ must be stable when exposed to a multitude of degradation pathways, namely, thermal, chemical, and mechanical. We subjected HYDRAFIL™ to accelerated thermal and chemical degradation pathways and described compositional, physical and chemical property changes using a kinetic framework. HYDRAFIL™ exhibited evidence of degradation when subject to extreme, atypical conditions, but proved to be stable in response to clinically and physiologically relevant pathways of degradation. To assess mechanical degradation, we generated HYDRAFIL™ particulates using cryogenic milling to mimic long-term mechanical wear particulates Morphological changes and shape descriptors were evaluated when HYDRAFIL™ was cryogenically milled under different cooling phases and grinding cycles. Particulates were evaluated in a rabbit model and showed excellent biocompatibility and safety, even within the spinal canal.","abstract_html":"HYDRAFIL™ is a poly(vinyl alcohol)/poly(ethylene glycol)-based hydrogel nucleus pulposus replacement device that is injected in situ and has demonstrated efficacy in lowering the prevalence and pain associated with back. In this work, we developed a method to analyze HYDRAFIL™ polymer composition using (TGA) and characterized intermolecular bonding interactions within the hydrogel through (FTIR). To function as a permanent implant for nucleus pulposus replacement, HYDRAFIL™ must be stable when exposed to a multitude of degradation pathways, namely, thermal, chemical, and mechanical. We subjected HYDRAFIL™ to accelerated thermal and chemical degradation pathways and described compositional, physical and chemical property changes using a kinetic framework. HYDRAFIL™ exhibited evidence of degradation when subject to extreme, atypical conditions, but proved to be stable in response to clinically and physiologically relevant pathways of degradation. To assess mechanical degradation, we generated HYDRAFIL™ particulates using cryogenic milling to mimic long-term mechanical wear particulates Morphological changes and shape descriptors were evaluated when HYDRAFIL™ was cryogenically milled under different cooling phases and grinding cycles. Particulates were evaluated in a rabbit model and showed excellent biocompatibility and safety, even within the spinal canal.","abstract_has_math":false,"creators":["Abbondandolo, Antonio G."],"institution":null,"degree_name":"Master of Science in Biomedical Engineering","degree_level":"Thesis","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Erik Brewer, Ph.D.","Anthony Lowman, Ph.D.","Joseph F. Stanzione, III, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:59:33Z","subjects":["Degradation","FTIR","Hydrolysis","Polymer","TGA","Thermal Oxidation","Intervertebral disk prostheses","Implants, Artificial","Biomedical Engineering and Bioengineering","Orthotics and Prosthetics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://rdw.rowan.edu/etd/3133","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://rdw.rowan.edu/etd/3133","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://rdw.rowan.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ardw.rowan.edu%3Aetd-4136","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Erik Brewer, Ph.D.","Anthony Lowman, Ph.D.","Joseph F. Stanzione, III, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Abbondandolo, Antonio G."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-06-15T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-06-14T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Degradation","FTIR","Hydrolysis","Polymer","TGA","Thermal Oxidation","Intervertebral disk prostheses","Implants, Artificial","Biomedical Engineering and Bioengineering","Orthotics and Prosthetics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://rdw.rowan.edu/etd/3133"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["HYDRAFIL™ is a poly(vinyl alcohol)/poly(ethylene glycol)-based hydrogel nucleus pulposus replacement device that is injected in situ and has demonstrated efficacy in lowering the prevalence and pain associated with back. In this work, we developed a method to analyze HYDRAFIL™ polymer composition using (TGA) and characterized intermolecular bonding interactions within the hydrogel through (FTIR). To function as a permanent implant for nucleus pulposus replacement, HYDRAFIL™ must be stable when exposed to a multitude of degradation pathways, namely, thermal, chemical, and mechanical. We subjected HYDRAFIL™ to accelerated thermal and chemical degradation pathways and described compositional, physical and chemical property changes using a kinetic framework. HYDRAFIL™ exhibited evidence of degradation when subject to extreme, atypical conditions, but proved to be stable in response to clinically and physiologically relevant pathways of degradation. To assess mechanical degradation, we generated HYDRAFIL™ particulates using cryogenic milling to mimic long-term mechanical wear particulates Morphological changes and shape descriptors were evaluated when HYDRAFIL™ was cryogenically milled under different cooling phases and grinding cycles. Particulates were evaluated in a rabbit model and showed excellent biocompatibility and safety, even within the spinal canal."]},{"key":"dc:title","label":"Title","values":["CHEMICAL AND POLYMER CHARACTERIZATION OF THE POTENTIAL MODES OF DEGRADATION OF AN INJECTABLE NUCLEUS PULPOSUS REPLACEMENT DEVICE"]}]}],"canonical_facts":{"dc:contributor":["Erik Brewer, Ph.D.","Anthony Lowman, Ph.D.","Joseph F. Stanzione, III, Ph.D."],"dc:creator":["Abbondandolo, Antonio G."],"dc:date.available":["2023-06-15T07:00:00Z"],"dc:date.created":["2023-06-14T07:00:00Z"],"dc:description.abstract":["HYDRAFIL™ is a poly(vinyl alcohol)/poly(ethylene glycol)-based hydrogel nucleus pulposus replacement device that is injected in situ and has demonstrated efficacy in lowering the prevalence and pain associated with back. In this work, we developed a method to analyze HYDRAFIL™ polymer composition using (TGA) and characterized intermolecular bonding interactions within the hydrogel through (FTIR). To function as a permanent implant for nucleus pulposus replacement, HYDRAFIL™ must be stable when exposed to a multitude of degradation pathways, namely, thermal, chemical, and mechanical. We subjected HYDRAFIL™ to accelerated thermal and chemical degradation pathways and described compositional, physical and chemical property changes using a kinetic framework. HYDRAFIL™ exhibited evidence of degradation when subject to extreme, atypical conditions, but proved to be stable in response to clinically and physiologically relevant pathways of degradation. To assess mechanical degradation, we generated HYDRAFIL™ particulates using cryogenic milling to mimic long-term mechanical wear particulates Morphological changes and shape descriptors were evaluated when HYDRAFIL™ was cryogenically milled under different cooling phases and grinding cycles. Particulates were evaluated in a rabbit model and showed excellent biocompatibility and safety, even within the spinal canal."],"dc:identifier":["https://rdw.rowan.edu/etd/3133"],"dc:subject":["Degradation","FTIR","Hydrolysis","Polymer","TGA","Thermal Oxidation","Intervertebral disk prostheses","Implants, Artificial","Biomedical Engineering and Bioengineering","Orthotics and Prosthetics"],"dc:title":["CHEMICAL AND POLYMER CHARACTERIZATION OF THE POTENTIAL MODES OF DEGRADATION OF AN INJECTABLE NUCLEUS PULPOSUS REPLACEMENT DEVICE"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Biomedical Engineering"]},"updated_at":"2026-11-19T08:59:33Z"}