{"id":{"repo_id":"rowan","oai_identifier":"oai:rdw.rowan.edu:etd-4181"},"canonical_url":"https://search.ndltd.org/etd/rowan/oai:rdw.rowan.edu:etd-4181","repository":{"repo_id":"rowan","name":"Rowan University","base_url":"https://rdw.rowan.edu/do/oai/"},"display":{"title":"Fabrication and Characterization of Flexible Microelectrode Arrays On Kapton Polyimide For Implantable Spinal Cord Stimulation Applications","abstract":"Recent advances in spinal cord stimulation (SCS) technology have made a significant impact in the treatment of chronic pain which is a prevalent issue amongst 20% of the population in developed nations. A few medical device manufactures have developed SCS devices that have been studied in clinical environments and reported to be effective and safe for commercial use. However, the current SCS devices available are bulky, rigid, and still present infection, fibrosis, discomfort, pulse delivery challenges and other concerns for patients. In this study, flexible electrodes processed on Kapton® polyimide films by physical vapor and inkjet deposition are fabricated and investigated to address some of these issues. The electrodes are composed of an initial layer of silver (Ag) or copper (Cu) conductive metal, followed by a titanium (Ti) buffer layer, and FDA approved titanium nitride (TiN) coating to create a multilayered, flexible, thin, biocompatible, efficient, minimally invasive, and functional lead. Flexible lead and electrode specimen are prepared and tested to evaluate the metal-to-polymer adhesion strength, resistivity under mechanical bending and stretching, and charge exchange properties. The results demonstrate that the flexible lead coatings are safe, thin, light, strongly adhered, durable, with efficient charge exchange characteristics, which make them a viable option for implantable SCS applications.","abstract_html":"Recent advances in spinal cord stimulation (SCS) technology have made a significant impact in the treatment of chronic pain which is a prevalent issue amongst 20% of the population in developed nations. A few medical device manufactures have developed SCS devices that have been studied in clinical environments and reported to be effective and safe for commercial use. However, the current SCS devices available are bulky, rigid, and still present infection, fibrosis, discomfort, pulse delivery challenges and other concerns for patients. In this study, flexible electrodes processed on Kapton® polyimide films by physical vapor and inkjet deposition are fabricated and investigated to address some of these issues. The electrodes are composed of an initial layer of silver (Ag) or copper (Cu) conductive metal, followed by a titanium (Ti) buffer layer, and FDA approved titanium nitride (TiN) coating to create a multilayered, flexible, thin, biocompatible, efficient, minimally invasive, and functional lead. Flexible lead and electrode specimen are prepared and tested to evaluate the metal-to-polymer adhesion strength, resistivity under mechanical bending and stretching, and charge exchange properties. The results demonstrate that the flexible lead coatings are safe, thin, light, strongly adhered, durable, with efficient charge exchange characteristics, which make them a viable option for implantable SCS applications.","abstract_has_math":false,"creators":["Jamhour, Nabil"],"institution":null,"degree_name":"Master of Science (M.S.)","degree_level":"Thesis","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Wei Xue, Ph.D. and Jeffrey Hettinger, Ph.D.","Francis Haas, Ph.D.","Lei Yu, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:59:40Z","subjects":["Chronic Pain Management; Electrode Coatings; Flexible Electronics; Flexible Spinal Cord Stimulator; Stencil Lithography","Spinal implants","Chronic pain--Treatment","Kapton (Trademark)","Biomedical Engineering and Bioengineering","Materials Science and Engineering","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://rdw.rowan.edu/etd/3175","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://rdw.rowan.edu/etd/3175","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://rdw.rowan.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ardw.rowan.edu%3Aetd-4181","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Wei Xue, Ph.D. and Jeffrey Hettinger, Ph.D.","Francis Haas, Ph.D.","Lei Yu, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Jamhour, Nabil"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-12-14T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-12-15T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chronic Pain Management; Electrode Coatings; Flexible Electronics; Flexible Spinal Cord Stimulator; Stencil Lithography","Spinal implants","Chronic pain--Treatment","Kapton (Trademark)","Biomedical Engineering and Bioengineering","Materials Science and Engineering","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://rdw.rowan.edu/etd/3175"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Recent advances in spinal cord stimulation (SCS) technology have made a significant impact in the treatment of chronic pain which is a prevalent issue amongst 20% of the population in developed nations. A few medical device manufactures have developed SCS devices that have been studied in clinical environments and reported to be effective and safe for commercial use. However, the current SCS devices available are bulky, rigid, and still present infection, fibrosis, discomfort, pulse delivery challenges and other concerns for patients. In this study, flexible electrodes processed on Kapton® polyimide films by physical vapor and inkjet deposition are fabricated and investigated to address some of these issues. The electrodes are composed of an initial layer of silver (Ag) or copper (Cu) conductive metal, followed by a titanium (Ti) buffer layer, and FDA approved titanium nitride (TiN) coating to create a multilayered, flexible, thin, biocompatible, efficient, minimally invasive, and functional lead. Flexible lead and electrode specimen are prepared and tested to evaluate the metal-to-polymer adhesion strength, resistivity under mechanical bending and stretching, and charge exchange properties. The results demonstrate that the flexible lead coatings are safe, thin, light, strongly adhered, durable, with efficient charge exchange characteristics, which make them a viable option for implantable SCS applications."]},{"key":"dc:title","label":"Title","values":["Fabrication and Characterization of Flexible Microelectrode Arrays On Kapton Polyimide For Implantable Spinal Cord Stimulation Applications"]}]}],"canonical_facts":{"dc:contributor":["Wei Xue, Ph.D. and Jeffrey Hettinger, Ph.D.","Francis Haas, Ph.D.","Lei Yu, Ph.D."],"dc:creator":["Jamhour, Nabil"],"dc:date.available":["2025-12-14T08:00:00Z"],"dc:date.created":["2023-12-15T08:00:00Z"],"dc:description.abstract":["Recent advances in spinal cord stimulation (SCS) technology have made a significant impact in the treatment of chronic pain which is a prevalent issue amongst 20% of the population in developed nations. A few medical device manufactures have developed SCS devices that have been studied in clinical environments and reported to be effective and safe for commercial use. However, the current SCS devices available are bulky, rigid, and still present infection, fibrosis, discomfort, pulse delivery challenges and other concerns for patients. In this study, flexible electrodes processed on Kapton® polyimide films by physical vapor and inkjet deposition are fabricated and investigated to address some of these issues. The electrodes are composed of an initial layer of silver (Ag) or copper (Cu) conductive metal, followed by a titanium (Ti) buffer layer, and FDA approved titanium nitride (TiN) coating to create a multilayered, flexible, thin, biocompatible, efficient, minimally invasive, and functional lead. Flexible lead and electrode specimen are prepared and tested to evaluate the metal-to-polymer adhesion strength, resistivity under mechanical bending and stretching, and charge exchange properties. The results demonstrate that the flexible lead coatings are safe, thin, light, strongly adhered, durable, with efficient charge exchange characteristics, which make them a viable option for implantable SCS applications."],"dc:identifier":["https://rdw.rowan.edu/etd/3175"],"dc:subject":["Chronic Pain Management; Electrode Coatings; Flexible Electronics; Flexible Spinal Cord Stimulator; Stencil Lithography","Spinal implants","Chronic pain--Treatment","Kapton (Trademark)","Biomedical Engineering and Bioengineering","Materials Science and Engineering","Mechanical Engineering"],"dc:title":["Fabrication and Characterization of Flexible Microelectrode Arrays On Kapton Polyimide For Implantable Spinal Cord Stimulation Applications"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (M.S.)"]},"updated_at":"2026-11-19T08:59:40Z"}