{"id":{"repo_id":"rowan","oai_identifier":"oai:rdw.rowan.edu:etd-4302"},"canonical_url":"https://search.ndltd.org/etd/rowan/oai:rdw.rowan.edu:etd-4302","repository":{"repo_id":"rowan","name":"Rowan University","base_url":"https://rdw.rowan.edu/do/oai/"},"display":{"title":"INJECTABLE HYDROGELS THAT CAN MEASURE RADIATION AT BODY TEMPERATURE","abstract":"Hydrogel-based radiation dosimeters are used to calibrate and validate radiation delivered by linear accelerators used in radiotherapy. Specifically, Fricke hydrogel-based dosimeters containing ferrous ion complexes oxidize upon exposure to radiation, leading to a change in optical density that can be measured via a color change in a photometric reagent. While gelatin-based Fricke hydrogels are routinely used to measure radiation, these hydrogels are unstable at body temperature, and it is currently not possible to noninvasively measure radiation dose inside a patient. This study reports the synthesis and characterization of self-forming hydrogels containing Fricke components that are stable at body temperature. The effects of varying individual Fricke hydrogel components on the sensitivity (measured by change in optical density) to radiation dose were systematically studied. Self-forming hydrogels were prepared using xylenol orange (XO) in the range of 0.05 to 0.5 mM, ferrous ammonium sulfate (Mohr’s salt) in the range of 0.1 to 1 mM, and sulfuric acid (H2SO4) in the range of 0 to 100 mM. The minimum concentration of Fricke components to create self-forming hydrogels that are sensitive to radiation dose (0 to 40 Gy) at room and body temperature was found to be XO (0.2 mM), H2SO4, (25 mM) and Mohr’s salt (0.5 mM). To assess self-forming hydrogel biocompatibility, human mesenchymal stem cells (MSCs) cultured in medium were exposed to cylindrical hydrogels containing Fricke components, and MSCs co-cultured with self-forming hydrogels containing the optimized formulation remained highly viable. Plans for a preclinical study using a rodent tumor model are underway, bringing this technology one step closer to clinical practice.","abstract_html":"Hydrogel-based radiation dosimeters are used to calibrate and validate radiation delivered by linear accelerators used in radiotherapy. Specifically, Fricke hydrogel-based dosimeters containing ferrous ion complexes oxidize upon exposure to radiation, leading to a change in optical density that can be measured via a color change in a photometric reagent. While gelatin-based Fricke hydrogels are routinely used to measure radiation, these hydrogels are unstable at body temperature, and it is currently not possible to noninvasively measure radiation dose inside a patient. This study reports the synthesis and characterization of self-forming hydrogels containing Fricke components that are stable at body temperature. The effects of varying individual Fricke hydrogel components on the sensitivity (measured by change in optical density) to radiation dose were systematically studied. Self-forming hydrogels were prepared using xylenol orange (XO) in the range of 0.05 to 0.5 mM, ferrous ammonium sulfate (Mohr’s salt) in the range of 0.1 to 1 mM, and sulfuric acid (H2SO4) in the range of 0 to 100 mM. The minimum concentration of Fricke components to create self-forming hydrogels that are sensitive to radiation dose (0 to 40 Gy) at room and body temperature was found to be XO (0.2 mM), H2SO4, (25 mM) and Mohr’s salt (0.5 mM). To assess self-forming hydrogel biocompatibility, human mesenchymal stem cells (MSCs) cultured in medium were exposed to cylindrical hydrogels containing Fricke components, and MSCs co-cultured with self-forming hydrogels containing the optimized formulation remained highly viable. Plans for a preclinical study using a rodent tumor model are underway, bringing this technology one step closer to clinical practice.","abstract_has_math":false,"creators":["Ball, Daniel Joseph"],"institution":null,"degree_name":"Master of Science (M.S.)","degree_level":"Thesis","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Sebastian Vega, Ph.D.","Erik Brewer, Ph.D.","Leonard Kim, D.A.B.R."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:59:46Z","subjects":["radiation dosimeters","Fricke hydrogels","Radiation dosimetry","Biomedical Engineering and Bioengineering","Chemical Engineering","Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://rdw.rowan.edu/etd/3296","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://rdw.rowan.edu/etd/3296","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://rdw.rowan.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ardw.rowan.edu%3Aetd-4302","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sebastian Vega, Ph.D.","Erik Brewer, Ph.D.","Leonard Kim, D.A.B.R."]},{"key":"dc:creator","label":"Author","values":["Ball, Daniel Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-09-24T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-09-23T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["radiation dosimeters","Fricke hydrogels","Radiation dosimetry","Biomedical Engineering and Bioengineering","Chemical Engineering","Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://rdw.rowan.edu/etd/3296"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hydrogel-based radiation dosimeters are used to calibrate and validate radiation delivered by linear accelerators used in radiotherapy. Specifically, Fricke hydrogel-based dosimeters containing ferrous ion complexes oxidize upon exposure to radiation, leading to a change in optical density that can be measured via a color change in a photometric reagent. While gelatin-based Fricke hydrogels are routinely used to measure radiation, these hydrogels are unstable at body temperature, and it is currently not possible to noninvasively measure radiation dose inside a patient. This study reports the synthesis and characterization of self-forming hydrogels containing Fricke components that are stable at body temperature. The effects of varying individual Fricke hydrogel components on the sensitivity (measured by change in optical density) to radiation dose were systematically studied. Self-forming hydrogels were prepared using xylenol orange (XO) in the range of 0.05 to 0.5 mM, ferrous ammonium sulfate (Mohr’s salt) in the range of 0.1 to 1 mM, and sulfuric acid (H2SO4) in the range of 0 to 100 mM. The minimum concentration of Fricke components to create self-forming hydrogels that are sensitive to radiation dose (0 to 40 Gy) at room and body temperature was found to be XO (0.2 mM), H2SO4, (25 mM) and Mohr’s salt (0.5 mM). To assess self-forming hydrogel biocompatibility, human mesenchymal stem cells (MSCs) cultured in medium were exposed to cylindrical hydrogels containing Fricke components, and MSCs co-cultured with self-forming hydrogels containing the optimized formulation remained highly viable. Plans for a preclinical study using a rodent tumor model are underway, bringing this technology one step closer to clinical practice."]},{"key":"dc:title","label":"Title","values":["INJECTABLE HYDROGELS THAT CAN MEASURE RADIATION AT BODY TEMPERATURE"]}]}],"canonical_facts":{"dc:contributor":["Sebastian Vega, Ph.D.","Erik Brewer, Ph.D.","Leonard Kim, D.A.B.R."],"dc:creator":["Ball, Daniel Joseph"],"dc:date.available":["2024-09-24T07:00:00Z"],"dc:date.created":["2024-09-23T07:00:00Z"],"dc:description.abstract":["Hydrogel-based radiation dosimeters are used to calibrate and validate radiation delivered by linear accelerators used in radiotherapy. Specifically, Fricke hydrogel-based dosimeters containing ferrous ion complexes oxidize upon exposure to radiation, leading to a change in optical density that can be measured via a color change in a photometric reagent. While gelatin-based Fricke hydrogels are routinely used to measure radiation, these hydrogels are unstable at body temperature, and it is currently not possible to noninvasively measure radiation dose inside a patient. This study reports the synthesis and characterization of self-forming hydrogels containing Fricke components that are stable at body temperature. The effects of varying individual Fricke hydrogel components on the sensitivity (measured by change in optical density) to radiation dose were systematically studied. Self-forming hydrogels were prepared using xylenol orange (XO) in the range of 0.05 to 0.5 mM, ferrous ammonium sulfate (Mohr’s salt) in the range of 0.1 to 1 mM, and sulfuric acid (H2SO4) in the range of 0 to 100 mM. The minimum concentration of Fricke components to create self-forming hydrogels that are sensitive to radiation dose (0 to 40 Gy) at room and body temperature was found to be XO (0.2 mM), H2SO4, (25 mM) and Mohr’s salt (0.5 mM). To assess self-forming hydrogel biocompatibility, human mesenchymal stem cells (MSCs) cultured in medium were exposed to cylindrical hydrogels containing Fricke components, and MSCs co-cultured with self-forming hydrogels containing the optimized formulation remained highly viable. Plans for a preclinical study using a rodent tumor model are underway, bringing this technology one step closer to clinical practice."],"dc:identifier":["https://rdw.rowan.edu/etd/3296"],"dc:subject":["radiation dosimeters","Fricke hydrogels","Radiation dosimetry","Biomedical Engineering and Bioengineering","Chemical Engineering","Engineering"],"dc:title":["INJECTABLE HYDROGELS THAT CAN MEASURE RADIATION AT BODY TEMPERATURE"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (M.S.)"]},"updated_at":"2026-11-19T08:59:46Z"}