{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/14376"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/14376","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"Gypsum Scaling in Bulk Neutralization Circuits","abstract":"Hydrometallurgical water treatment circuits experience substantial scaling due to the neutralization of sulphuric acid and precipitation of dissolved metals with slaked lime slurry. Operationally disruptive counter-measures, such as mechanical and chemical cleaning, are often required to remove scale and restore capacity to process equipment. The composition of scale formed in the Key Lake Bulk Neutralization circuits was characterized using X-Ray Powder Diffraction, Raman Spectroscopy, Scanning Electron Microscopy, and Energy Dispersive X-Ray Spectroscopy. The impact of hydrodynamics, and degree of super-saturation on the propensity for scale formation was evaluated using rotating cylindrical coupons to measure the induction period and specific scaling rate under conditions typical of Bulk Neutralization circuits located in Northern Saskatchewan.","abstract_html":"Hydrometallurgical water treatment circuits experience substantial scaling due to the neutralization of sulphuric acid and precipitation of dissolved metals with slaked lime slurry. Operationally disruptive counter-measures, such as mechanical and chemical cleaning, are often required to remove scale and restore capacity to process equipment. The composition of scale formed in the Key Lake Bulk Neutralization circuits was characterized using X-Ray Powder Diffraction, Raman Spectroscopy, Scanning Electron Microscopy, and Energy Dispersive X-Ray Spectroscopy. The impact of hydrodynamics, and degree of super-saturation on the propensity for scale formation was evaluated using rotating cylindrical coupons to measure the induction period and specific scaling rate under conditions typical of Bulk Neutralization circuits located in Northern Saskatchewan.","abstract_has_math":false,"creators":["Tennant, Derek"],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":"Chemical Engineering","degree_department":"Chemical and Biological Engineering","school":null,"contributors":[],"advisors":["Evitts, Richard","Heppner, Kevin"],"committee_chairs":[],"committee_members":["Soltan Mohammadzadeh, Jafar","Oguocha, Ike"],"year":2022,"date_issued":"2022-12-16","date_published":"2022-12-16","updated_at":"2026-11-19T10:01:26Z","subjects":["Bulk Neutralization","Rotating Cylinder Electrode","Gypsum","Scaling"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10388/14376","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/14376","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F14376","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F14376","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Evitts, Richard","Heppner, Kevin"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Soltan Mohammadzadeh, Jafar","Oguocha, Ike"]},{"key":"dc:creator","label":"Author","values":["Tennant, Derek"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-12-16T15:44:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-12-16T15:44:06Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2022"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-12"]},{"key":"dc:date.issued","label":"Date","values":["2022-12-16"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2022"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2022-12-16T15:44:07Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Chemical and Biological Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bulk Neutralization","Rotating Cylinder Electrode","Gypsum","Scaling"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/14376"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hydrometallurgical water treatment circuits experience substantial scaling due to the neutralization of sulphuric acid and precipitation of dissolved metals with slaked lime slurry. Operationally disruptive counter-measures, such as mechanical and chemical cleaning, are often required to remove scale and restore capacity to process equipment. The composition of scale formed in the Key Lake Bulk Neutralization circuits was characterized using X-Ray Powder Diffraction, Raman Spectroscopy, Scanning Electron Microscopy, and Energy Dispersive X-Ray Spectroscopy. The impact of hydrodynamics, and degree of super-saturation on the propensity for scale formation was evaluated using rotating cylindrical coupons to measure the induction period and specific scaling rate under conditions typical of Bulk Neutralization circuits located in Northern Saskatchewan."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Gypsum Scaling in Bulk Neutralization Circuits"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Evitts, Richard","Heppner, Kevin"],"dc:contributor.committeemember":["Soltan Mohammadzadeh, Jafar","Oguocha, Ike"],"dc:creator":["Tennant, Derek"],"dc:date.accessioned":["2022-12-16T15:44:06Z"],"dc:date.available":["2022-12-16T15:44:06Z"],"dc:date.copyright":["2022"],"dc:date.created":["2022-12"],"dc:date.issued":["2022-12-16"],"dc:date.submitted":["December 2022"],"dc:date.updated":["2022-12-16T15:44:07Z"],"dc:description.abstract":["Hydrometallurgical water treatment circuits experience substantial scaling due to the neutralization of sulphuric acid and precipitation of dissolved metals with slaked lime slurry. Operationally disruptive counter-measures, such as mechanical and chemical cleaning, are often required to remove scale and restore capacity to process equipment. The composition of scale formed in the Key Lake Bulk Neutralization circuits was characterized using X-Ray Powder Diffraction, Raman Spectroscopy, Scanning Electron Microscopy, and Energy Dispersive X-Ray Spectroscopy. The impact of hydrodynamics, and degree of super-saturation on the propensity for scale formation was evaluated using rotating cylindrical coupons to measure the induction period and specific scaling rate under conditions typical of Bulk Neutralization circuits located in Northern Saskatchewan."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/14376"],"dc:language.iso":["en"],"dc:subject":["Bulk Neutralization","Rotating Cylinder Electrode","Gypsum","Scaling"],"dc:title":["Gypsum Scaling in Bulk Neutralization Circuits"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_department":["Chemical and Biological Engineering"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:01:26Z"}