Back to results

University of Saskatchewan

Radio Frequency Power Amplifiers Adapted For Low Field Magnetic Resonance Imaging

Abstract

dc:description.abstract

Magnetic Resonance Imaging (MRI) is a reliable and established minimally invasive imaging technique that can provide diagnostically relevant information about the internal structures of the human body. While the basic design of the new MRI scanners is not much different from when they were first designed a few decades ago, finding new ways to modify these big, power-hungry, expensive and complex systems is becoming more and more essential. One of the ways of removing the restrictions that conventional MRI systems have is making them low field. This leads to lighter, smaller, simpler and less expensive MRI scanners that can potentially become portable. Once they are portable, MRI scanners can have various applications ranging from being used in emergency and operating rooms to being taken to remote areas and even outer space. The Space MRI Lab at the University of Saskatchewan focuses on building prototypes of portable MRIs for monitoring astronaut health by using TRansmit Array Spatial Encoding (TRASE). TRASE is an innovative MRI method that operates without relying on noisy, heavy and complex gradient coils. In TRASE, the spatial encoding happens based on the phase gradients of the transmit radio frequency (RF) magnetic field. TRASE-based MRI scanners have specific requirements. One of those requirements is RF power amplifiers (RFPAs) with high-power RF output, high duty cycle and fast switching times. These characteristics are important for achieving maximal TRASE MRI resolution. However, since no commercially available RFPA with these specifications exists, it was necessary to build RFPAs customized for TRASE applications. A class A/B Ham radio power amplifier design was modified to be more compatible with TRASE-based MRIs. As part of this thesis, two of these RFPAs were constructed at the University of Saskatchewan Space MRI Lab. The RFPAs were assembled to be used with the Merlin MRI, an ankle-sized portable MRI tested in zero-gravity which uses TRASE. Fortunately, both of the RFPAs showed expected results at the testing stage and have since been integrated with the Merlin MRI. Details of the assembly work are presented in this thesis.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Biomedical Engineering
Department thesis:degree_department
Biomedical Engineering
Grantor
University of Saskatchewan
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ebadollahi-Somee, Faezeh
Advisors dc:contributor.advisor
  • Sarty, Gordon
  • McWilliams, Kathryn
Committee members dc:contributor.committeemember
  • McWilliams, Kathryn
  • McWalter, Emily
  • Sharp, Jonathan
  • Bradley, Michael

Subjects

dc:subject × 8

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10388/14550

Chain of custody

source
Harvested from
University of Saskatchewan
Base URL
harvest.usask.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ebadollahi-Somee, Faezeh. Radio Frequency Power Amplifiers Adapted For Low Field Magnetic Resonance Imaging. Masters thesis, University of Saskatchewan, 2023. https://hdl.handle.net/10388/14550