{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/14897"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/14897","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"A Data-Driven Framework for Transformer Health Monitoring in Distribution Networks","abstract":"Distribution networks typically contain a large number of distribution transformers that are critical for high-quality uninterrupted energy delivery. Distribution transformers are the last portion in a power delivery system, their health is essential to ensure the reliability of distribution networks, and their failure may cause huge technical and economic problems to power utilities and customers. The distribution transformer failure may be influenced by its maintenance history, risk index in a distribution network associated with keraunic level, average number of lightning strikes, protection devices employed, dissolved gas analysis (DGA) data, overloading, and phase unbalance etc. To prevent sudden failures of transformers while meeting growing electricity demands, transformer health monitoring and failure prediction become increasingly important in operation and maintenance procedures for power utilities. To enhance reliable operation of transformers in distribution networks, an effective data-driven framework for the distribution transformer heath monitoring is proposed in this thesis, which is computationally efficient, accurate, reliable, and comprehensive to monitor the health of distribution transformers based on readily available lightning strike data, distribution networks risk index, DGA data, historical maintenance data, advanced metering infrastructure (AMI) data, roof-top photovoltaics (PV) production data, and electric vehicle (EV) charging stations data. To develop the proposed framework, first, a comprehensive literature review is conducted on data-driven approaches for distribution transformer health monitoring to understand research gaps; second, a novel distribution transformer failure prediction method through a hybrid one-class deep support vector data description (SVDD) is proposed using lightning strike data and distribution networks risk index data, and this method helps distribution transformer predictive maitenance; third, a novel data-driven hybrid approach is proposed to predict the health index (HI) of a transformer using DGA data, where a robust technique is used to handle missing or erroneous data due to sensor or data transfer issues, and five case studies with different percentages of missing data are used to validate the proposed approach; fourth, the combined impact of plug-in electric vehicles (PEV) charging load and roof-top PV is investigated through a case study in Saskatoon, Canada, the results show that the increased PEV adoption exacerbates the transformer stress, while PV integration mitigates these effects, especially during summer, and this highlights the need to encourage rooftop PV adoption to balance the PEV charging demand on transformers; finally, a novel hierarchical load forecast aggregation technique in distribution transformers using AMI data recorded by Saskatoon Light and Power in Canada is proposed to accurately predict each customer’s load, each transformer phase load and the total transformer load, which helps to determine the transformer overloading and load unbalance.","abstract_html":"Distribution networks typically contain a large number of distribution transformers that are critical for high-quality uninterrupted energy delivery. Distribution transformers are the last portion in a power delivery system, their health is essential to ensure the reliability of distribution networks, and their failure may cause huge technical and economic problems to power utilities and customers. The distribution transformer failure may be influenced by its maintenance history, risk index in a distribution network associated with keraunic level, average number of lightning strikes, protection devices employed, dissolved gas analysis (DGA) data, overloading, and phase unbalance etc. To prevent sudden failures of transformers while meeting growing electricity demands, transformer health monitoring and failure prediction become increasingly important in operation and maintenance procedures for power utilities. To enhance reliable operation of transformers in distribution networks, an effective data-driven framework for the distribution transformer heath monitoring is proposed in this thesis, which is computationally efficient, accurate, reliable, and comprehensive to monitor the health of distribution transformers based on readily available lightning strike data, distribution networks risk index, DGA data, historical maintenance data, advanced metering infrastructure (AMI) data, roof-top photovoltaics (PV) production data, and electric vehicle (EV) charging stations data. To develop the proposed framework, first, a comprehensive literature review is conducted on data-driven approaches for distribution transformer health monitoring to understand research gaps; second, a novel distribution transformer failure prediction method through a hybrid one-class deep support vector data description (SVDD) is proposed using lightning strike data and distribution networks risk index data, and this method helps distribution transformer predictive maitenance; third, a novel data-driven hybrid approach is proposed to predict the health index (HI) of a transformer using DGA data, where a robust technique is used to handle missing or erroneous data due to sensor or data transfer issues, and five case studies with different percentages of missing data are used to validate the proposed approach; fourth, the combined impact of plug-in electric vehicles (PEV) charging load and roof-top PV is investigated through a case study in Saskatoon, Canada, the results show that the increased PEV adoption exacerbates the transformer stress, while PV integration mitigates these effects, especially during summer, and this highlights the need to encourage rooftop PV adoption to balance the PEV charging demand on transformers; finally, a novel hierarchical load forecast aggregation technique in distribution transformers using AMI data recorded by Saskatoon Light and Power in Canada is proposed to accurately predict each customer’s load, each transformer phase load and the total transformer load, which helps to determine the transformer overloading and load unbalance.","abstract_has_math":false,"creators":["Mogos, Aman Samson"],"institution":"University of Saskatchewan","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Liang, Xiaodong","Chung, Tony"],"committee_chairs":[],"committee_members":["Hany, Farag","Mehr, Aryan S","Zhang, Chris","Chen, Li","Faried, Sherif"],"year":2023,"date_issued":"2023-08-17","date_published":"2023-08-17","updated_at":"2026-11-19T10:11:34Z","subjects":["Distribution Transformer","Health Monitoring","Data-based approaches","Machine Learning","Health Index"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0003-3534-1246"],"render_values":[{"text":"0000-0003-3534-1246","href":"https://orcid.org/0000-0003-3534-1246","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/10388/14897","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/14897","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2024-08-17","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F14897","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F14897","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Liang, Xiaodong","Chung, Tony"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hany, Farag","Mehr, Aryan S","Zhang, Chris","Chen, Li","Faried, Sherif"]},{"key":"dc:creator","label":"Author","values":["Mogos, Aman Samson"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0003-3534-1246"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-08-17T21:10:35Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-11"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2024-08-17"]},{"key":"dc:date.issued","label":"Date","values":["2023-08-17"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2024-08-17"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["November 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2023-08-17T21:10:35Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Distribution Transformer","Health Monitoring","Data-based approaches","Machine Learning","Health Index"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/14897"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Distribution networks typically contain a large number of distribution transformers that are critical for high-quality uninterrupted energy delivery. Distribution transformers are the last portion in a power delivery system, their health is essential to ensure the reliability of distribution networks, and their failure may cause huge technical and economic problems to power utilities and customers. The distribution transformer failure may be influenced by its maintenance history, risk index in a distribution network associated with keraunic level, average number of lightning strikes, protection devices employed, dissolved gas analysis (DGA) data, overloading, and phase unbalance etc. To prevent sudden failures of transformers while meeting growing electricity demands, transformer health monitoring and failure prediction become increasingly important in operation and maintenance procedures for power utilities. To enhance reliable operation of transformers in distribution networks, an effective data-driven framework for the distribution transformer heath monitoring is proposed in this thesis, which is computationally efficient, accurate, reliable, and comprehensive to monitor the health of distribution transformers based on readily available lightning strike data, distribution networks risk index, DGA data, historical maintenance data, advanced metering infrastructure (AMI) data, roof-top photovoltaics (PV) production data, and electric vehicle (EV) charging stations data. To develop the proposed framework, first, a comprehensive literature review is conducted on data-driven approaches for distribution transformer health monitoring to understand research gaps; second, a novel distribution transformer failure prediction method through a hybrid one-class deep support vector data description (SVDD) is proposed using lightning strike data and distribution networks risk index data, and this method helps distribution transformer predictive maitenance; third, a novel data-driven hybrid approach is proposed to predict the health index (HI) of a transformer using DGA data, where a robust technique is used to handle missing or erroneous data due to sensor or data transfer issues, and five case studies with different percentages of missing data are used to validate the proposed approach; fourth, the combined impact of plug-in electric vehicles (PEV) charging load and roof-top PV is investigated through a case study in Saskatoon, Canada, the results show that the increased PEV adoption exacerbates the transformer stress, while PV integration mitigates these effects, especially during summer, and this highlights the need to encourage rooftop PV adoption to balance the PEV charging demand on transformers; finally, a novel hierarchical load forecast aggregation technique in distribution transformers using AMI data recorded by Saskatoon Light and Power in Canada is proposed to accurately predict each customer’s load, each transformer phase load and the total transformer load, which helps to determine the transformer overloading and load unbalance."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A Data-Driven Framework for Transformer Health Monitoring in Distribution Networks"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Liang, Xiaodong","Chung, Tony"],"dc:contributor.committeemember":["Hany, Farag","Mehr, Aryan S","Zhang, Chris","Chen, Li","Faried, Sherif"],"dc:creator":["Mogos, Aman Samson"],"dc:date.accessioned":["2023-08-17T21:10:35Z"],"dc:date.copyright":["2023"],"dc:date.created":["2023-11"],"dc:date.embargo":["2024-08-17"],"dc:date.issued":["2023-08-17"],"dc:date.liftdate":["2024-08-17"],"dc:date.submitted":["November 2023"],"dc:date.updated":["2023-08-17T21:10:35Z"],"dc:description.abstract":["Distribution networks typically contain a large number of distribution transformers that are critical for high-quality uninterrupted energy delivery. Distribution transformers are the last portion in a power delivery system, their health is essential to ensure the reliability of distribution networks, and their failure may cause huge technical and economic problems to power utilities and customers. The distribution transformer failure may be influenced by its maintenance history, risk index in a distribution network associated with keraunic level, average number of lightning strikes, protection devices employed, dissolved gas analysis (DGA) data, overloading, and phase unbalance etc. To prevent sudden failures of transformers while meeting growing electricity demands, transformer health monitoring and failure prediction become increasingly important in operation and maintenance procedures for power utilities. To enhance reliable operation of transformers in distribution networks, an effective data-driven framework for the distribution transformer heath monitoring is proposed in this thesis, which is computationally efficient, accurate, reliable, and comprehensive to monitor the health of distribution transformers based on readily available lightning strike data, distribution networks risk index, DGA data, historical maintenance data, advanced metering infrastructure (AMI) data, roof-top photovoltaics (PV) production data, and electric vehicle (EV) charging stations data. To develop the proposed framework, first, a comprehensive literature review is conducted on data-driven approaches for distribution transformer health monitoring to understand research gaps; second, a novel distribution transformer failure prediction method through a hybrid one-class deep support vector data description (SVDD) is proposed using lightning strike data and distribution networks risk index data, and this method helps distribution transformer predictive maitenance; third, a novel data-driven hybrid approach is proposed to predict the health index (HI) of a transformer using DGA data, where a robust technique is used to handle missing or erroneous data due to sensor or data transfer issues, and five case studies with different percentages of missing data are used to validate the proposed approach; fourth, the combined impact of plug-in electric vehicles (PEV) charging load and roof-top PV is investigated through a case study in Saskatoon, Canada, the results show that the increased PEV adoption exacerbates the transformer stress, while PV integration mitigates these effects, especially during summer, and this highlights the need to encourage rooftop PV adoption to balance the PEV charging demand on transformers; finally, a novel hierarchical load forecast aggregation technique in distribution transformers using AMI data recorded by Saskatoon Light and Power in Canada is proposed to accurately predict each customer’s load, each transformer phase load and the total transformer load, which helps to determine the transformer overloading and load unbalance."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/14897"],"dc:language.iso":["en"],"dc:subject":["Distribution Transformer","Health Monitoring","Data-based approaches","Machine Learning","Health Index"],"dc:title":["A Data-Driven Framework for Transformer Health Monitoring in Distribution Networks"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"person:identifier.orcid":["0000-0003-3534-1246"],"thesis:degree_department":["Electrical and Computer Engineering"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:11:34Z"}