{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/15544"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/15544","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"A TECHNIQUE FOR ESTIMATING TRANSMISSION LINE FAULT LOCATIONS FROM DIGITAL IMPEDANCE RELAY MEASUREMENTS","abstract":"The usual approach for estimating locations of transmission line shunt faults has been to measure the apparent impedance to the fault from a line terminal and convert the impedance to line length. One factor that adversely affects fault location estimates is the fault resistance that appears to the relay to be an impedance that has both resistive and reactive components if the fault current is supplied from both line terminals. Several methods that estimate transmission line fault locations have been proposed in the past. These methods use fundamental frequency voltages and currents measured at one or both line terminals. The accuracy of the methods that use data from one line terminal depends on the accuracy of the estimates of source impedances and fault current distribution factors. The accuracy of the methods that use data from two line terminals depends on the synchronization of the measurements taken at two line terminals. This thesis presents a technique that estimates the location of a transmission line shunt fault from fundamental frequency voltages and currents measured at the line terminals. The technique uses apparent impedances as seen from the terminals of a transmission line. Line charging is initially neglected and is later taken into consideration. Results from computer simulations of single and multi-phase faults on a 500 kV line inter-connecting two power systems are presented. The results indicate that the proposed method is quite accurate even when fault resistances are numerically comparable to the line impedances. The observations from the two line terminals do not have to be synchronized. Source impedances, distribution factors and pre-fault currents are not needed by the estimation procedure.","abstract_html":"The usual approach for estimating locations of transmission line shunt faults has been to measure the apparent impedance to the fault from a line terminal and convert the impedance to line length. One factor that adversely affects fault location estimates is the fault resistance that appears to the relay to be an impedance that has both resistive and reactive components if the fault current is supplied from both line terminals. Several methods that estimate transmission line fault locations have been proposed in the past. These methods use fundamental frequency voltages and currents measured at one or both line terminals. The accuracy of the methods that use data from one line terminal depends on the accuracy of the estimates of source impedances and fault current distribution factors. The accuracy of the methods that use data from two line terminals depends on the synchronization of the measurements taken at two line terminals. This thesis presents a technique that estimates the location of a transmission line shunt fault from fundamental frequency voltages and currents measured at the line terminals. The technique uses apparent impedances as seen from the terminals of a transmission line. Line charging is initially neglected and is later taken into consideration. Results from computer simulations of single and multi-phase faults on a 500 kV line inter-connecting two power systems are presented. The results indicate that the proposed method is quite accurate even when fault resistances are numerically comparable to the line impedances. The observations from the two line terminals do not have to be synchronized. Source impedances, distribution factors and pre-fault currents are not needed by the estimation procedure.","abstract_has_math":false,"creators":["Agarwal, Rajendra"],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":null,"degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1985,"date_issued":"1985-03","date_published":"1985-03","updated_at":"2026-11-19T10:00:54Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10388/15544","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/15544","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F15544","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Agarwal, Rajendra"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-04-01T22:07:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-04-01T22:07:30Z"]},{"key":"dc:date.issued","label":"Date","values":["1985-03"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["March 1985"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/15544"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The usual approach for estimating locations of transmission line shunt faults has been to measure the apparent impedance to the fault from a line terminal and convert the impedance to line length. One factor that adversely affects fault location estimates is the fault resistance that appears to the relay to be an impedance that has both resistive and reactive components if the fault current is supplied from both line terminals. Several methods that estimate transmission line fault locations have been proposed in the past. These methods use fundamental frequency voltages and currents measured at one or both line terminals. The accuracy of the methods that use data from one line terminal depends on the accuracy of the estimates of source impedances and fault current distribution factors. The accuracy of the methods that use data from two line terminals depends on the synchronization of the measurements taken at two line terminals. This thesis presents a technique that estimates the location of a transmission line shunt fault from fundamental frequency voltages and currents measured at the line terminals. The technique uses apparent impedances as seen from the terminals of a transmission line. Line charging is initially neglected and is later taken into consideration. Results from computer simulations of single and multi-phase faults on a 500 kV line inter-connecting two power systems are presented. The results indicate that the proposed method is quite accurate even when fault resistances are numerically comparable to the line impedances. The observations from the two line terminals do not have to be synchronized. Source impedances, distribution factors and pre-fault currents are not needed by the estimation procedure."]},{"key":"dc:title","label":"Title","values":["A TECHNIQUE FOR ESTIMATING TRANSMISSION LINE FAULT LOCATIONS FROM DIGITAL IMPEDANCE RELAY MEASUREMENTS"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Agarwal, Rajendra"],"dc:date.accessioned":["2024-04-01T22:07:30Z"],"dc:date.available":["2024-04-01T22:07:30Z"],"dc:date.issued":["1985-03"],"dc:date.submitted":["March 1985"],"dc:description.abstract":["The usual approach for estimating locations of transmission line shunt faults has been to measure the apparent impedance to the fault from a line terminal and convert the impedance to line length. One factor that adversely affects fault location estimates is the fault resistance that appears to the relay to be an impedance that has both resistive and reactive components if the fault current is supplied from both line terminals. Several methods that estimate transmission line fault locations have been proposed in the past. These methods use fundamental frequency voltages and currents measured at one or both line terminals. The accuracy of the methods that use data from one line terminal depends on the accuracy of the estimates of source impedances and fault current distribution factors. The accuracy of the methods that use data from two line terminals depends on the synchronization of the measurements taken at two line terminals. This thesis presents a technique that estimates the location of a transmission line shunt fault from fundamental frequency voltages and currents measured at the line terminals. The technique uses apparent impedances as seen from the terminals of a transmission line. Line charging is initially neglected and is later taken into consideration. Results from computer simulations of single and multi-phase faults on a 500 kV line inter-connecting two power systems are presented. The results indicate that the proposed method is quite accurate even when fault resistances are numerically comparable to the line impedances. The observations from the two line terminals do not have to be synchronized. Source impedances, distribution factors and pre-fault currents are not needed by the estimation procedure."],"dc:identifier.uri":["https://hdl.handle.net/10388/15544"],"dc:title":["A TECHNIQUE FOR ESTIMATING TRANSMISSION LINE FAULT LOCATIONS FROM DIGITAL IMPEDANCE RELAY MEASUREMENTS"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:00:54Z"}