{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/15564"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/15564","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"Developing force feedback for human-robot interactions with telerobotic manipulators","abstract":"Robotic manipulators are being used for a growing number of applications. However, one concern with robotic manipulators is that they have a limited awareness of its environment. This can cause issues with safety or control of the manipulator. Therefore, it is important to develop sensor systems for different applications. This research is part of the Musculoskeletal Tele-robotic Imaging Machine (MSK-TIM) project at the University of Saskatchewan. The purpose of this project is to develop a remotely controlled robotic manipulator to conduct medical ultrasound examinations. In human-robot interactions, safety of the human is paramount. Therefore, this research investigates two different methods to measure the contact load: a load cell and a material model. To investigate using a load cell in a teleoperated system, a 1 degree-of-freedom (DOF) force sensor was installed, and remote control of the manipulator was developed. Other upgrades include developing a graphical user interface (GUI) and supporting remote control of ultrasound parameters. Using this system, an experienced radiologist conducted remote examination of 24 arms. Afterward, both the radiologist and participants reported their experience. The changes to the MSK-TIM were found to improve the function of the device, especially image quality. The visual force feedback was noted by the radiologist to be a useful tool as it indicated when the applied force exceeded recommended limits. To investigate the material-model method of obtain force-feedback, a finite element model of the arm-probe interaction was generated. The geometry of the soft tissue was obtained using photogrammetry. Experimental stiffness behaviour of the wrist was captured using the MSK-TIM. This data was used in model-correction analysis to obtain the first-order Ogden hyper-elastic material parameters of the soft tissue within the wrist. As a result, the developed finite element model could predict the contact force based on the displacement of the ultrasound probe into the skin. Several changes were then applied to the original model to optimize its computational efficiency. The final model was shown to be reasonable for real-time applications. As a result of this study, it has been shown that both a load cell and material model can be used to predict the contact force of a human-robot interaction.","abstract_html":"Robotic manipulators are being used for a growing number of applications. However, one concern with robotic manipulators is that they have a limited awareness of its environment. This can cause issues with safety or control of the manipulator. Therefore, it is important to develop sensor systems for different applications. This research is part of the Musculoskeletal Tele-robotic Imaging Machine (MSK-TIM) project at the University of Saskatchewan. The purpose of this project is to develop a remotely controlled robotic manipulator to conduct medical ultrasound examinations. In human-robot interactions, safety of the human is paramount. Therefore, this research investigates two different methods to measure the contact load: a load cell and a material model. To investigate using a load cell in a teleoperated system, a 1 degree-of-freedom (DOF) force sensor was installed, and remote control of the manipulator was developed. Other upgrades include developing a graphical user interface (GUI) and supporting remote control of ultrasound parameters. Using this system, an experienced radiologist conducted remote examination of 24 arms. Afterward, both the radiologist and participants reported their experience. The changes to the MSK-TIM were found to improve the function of the device, especially image quality. The visual force feedback was noted by the radiologist to be a useful tool as it indicated when the applied force exceeded recommended limits. To investigate the material-model method of obtain force-feedback, a finite element model of the arm-probe interaction was generated. The geometry of the soft tissue was obtained using photogrammetry. Experimental stiffness behaviour of the wrist was captured using the MSK-TIM. This data was used in model-correction analysis to obtain the first-order Ogden hyper-elastic material parameters of the soft tissue within the wrist. As a result, the developed finite element model could predict the contact force based on the displacement of the ultrasound probe into the skin. Several changes were then applied to the original model to optimize its computational efficiency. The final model was shown to be reasonable for real-time applications. As a result of this study, it has been shown that both a load cell and material model can be used to predict the contact force of a human-robot interaction.","abstract_has_math":false,"creators":["Ochitwa, Zachary"],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Fotouhi, Reza","Obaid, Haron"],"committee_chairs":[],"committee_members":["Johnston, J.D.","Ko, Seok Bum"],"year":2024,"date_issued":"2024-04-08","date_published":"2024-04-08","updated_at":"2026-11-19T10:01:17Z","subjects":["Force-feedback","Telemedicine","Robotics"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0009-0006-0526-6002"],"render_values":[{"text":"0009-0006-0526-6002","href":"https://orcid.org/0009-0006-0526-6002","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/10388/15564","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/15564","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2026-04-08","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F15564","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F15564","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fotouhi, Reza","Obaid, Haron"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Johnston, J.D.","Ko, Seok Bum"]},{"key":"dc:creator","label":"Author","values":["Ochitwa, Zachary"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0009-0006-0526-6002"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-04-09T02:32:47Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2024"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-02"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2026-04-08"]},{"key":"dc:date.issued","label":"Date","values":["2024-04-08"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2026-04-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["February 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-04-09T02:32:47Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Mechanical Engineering"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Force-feedback","Telemedicine","Robotics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/15564"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Robotic manipulators are being used for a growing number of applications. However, one concern with robotic manipulators is that they have a limited awareness of its environment. This can cause issues with safety or control of the manipulator. Therefore, it is important to develop sensor systems for different applications. This research is part of the Musculoskeletal Tele-robotic Imaging Machine (MSK-TIM) project at the University of Saskatchewan. The purpose of this project is to develop a remotely controlled robotic manipulator to conduct medical ultrasound examinations. In human-robot interactions, safety of the human is paramount. Therefore, this research investigates two different methods to measure the contact load: a load cell and a material model. To investigate using a load cell in a teleoperated system, a 1 degree-of-freedom (DOF) force sensor was installed, and remote control of the manipulator was developed. Other upgrades include developing a graphical user interface (GUI) and supporting remote control of ultrasound parameters. Using this system, an experienced radiologist conducted remote examination of 24 arms. Afterward, both the radiologist and participants reported their experience. The changes to the MSK-TIM were found to improve the function of the device, especially image quality. The visual force feedback was noted by the radiologist to be a useful tool as it indicated when the applied force exceeded recommended limits. To investigate the material-model method of obtain force-feedback, a finite element model of the arm-probe interaction was generated. The geometry of the soft tissue was obtained using photogrammetry. Experimental stiffness behaviour of the wrist was captured using the MSK-TIM. This data was used in model-correction analysis to obtain the first-order Ogden hyper-elastic material parameters of the soft tissue within the wrist. As a result, the developed finite element model could predict the contact force based on the displacement of the ultrasound probe into the skin. Several changes were then applied to the original model to optimize its computational efficiency. The final model was shown to be reasonable for real-time applications. As a result of this study, it has been shown that both a load cell and material model can be used to predict the contact force of a human-robot interaction."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Developing force feedback for human-robot interactions with telerobotic manipulators"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fotouhi, Reza","Obaid, Haron"],"dc:contributor.committeemember":["Johnston, J.D.","Ko, Seok Bum"],"dc:creator":["Ochitwa, Zachary"],"dc:date.accessioned":["2024-04-09T02:32:47Z"],"dc:date.copyright":["2024"],"dc:date.created":["2024-02"],"dc:date.embargo":["2026-04-08"],"dc:date.issued":["2024-04-08"],"dc:date.liftdate":["2026-04-08"],"dc:date.submitted":["February 2024"],"dc:date.updated":["2024-04-09T02:32:47Z"],"dc:description.abstract":["Robotic manipulators are being used for a growing number of applications. However, one concern with robotic manipulators is that they have a limited awareness of its environment. This can cause issues with safety or control of the manipulator. Therefore, it is important to develop sensor systems for different applications. This research is part of the Musculoskeletal Tele-robotic Imaging Machine (MSK-TIM) project at the University of Saskatchewan. The purpose of this project is to develop a remotely controlled robotic manipulator to conduct medical ultrasound examinations. In human-robot interactions, safety of the human is paramount. Therefore, this research investigates two different methods to measure the contact load: a load cell and a material model. To investigate using a load cell in a teleoperated system, a 1 degree-of-freedom (DOF) force sensor was installed, and remote control of the manipulator was developed. Other upgrades include developing a graphical user interface (GUI) and supporting remote control of ultrasound parameters. Using this system, an experienced radiologist conducted remote examination of 24 arms. Afterward, both the radiologist and participants reported their experience. The changes to the MSK-TIM were found to improve the function of the device, especially image quality. The visual force feedback was noted by the radiologist to be a useful tool as it indicated when the applied force exceeded recommended limits. To investigate the material-model method of obtain force-feedback, a finite element model of the arm-probe interaction was generated. The geometry of the soft tissue was obtained using photogrammetry. Experimental stiffness behaviour of the wrist was captured using the MSK-TIM. This data was used in model-correction analysis to obtain the first-order Ogden hyper-elastic material parameters of the soft tissue within the wrist. As a result, the developed finite element model could predict the contact force based on the displacement of the ultrasound probe into the skin. Several changes were then applied to the original model to optimize its computational efficiency. The final model was shown to be reasonable for real-time applications. As a result of this study, it has been shown that both a load cell and material model can be used to predict the contact force of a human-robot interaction."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/15564"],"dc:language.iso":["en"],"dc:subject":["Force-feedback","Telemedicine","Robotics"],"dc:title":["Developing force feedback for human-robot interactions with telerobotic manipulators"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"person:identifier.orcid":["0009-0006-0526-6002"],"thesis:degree_department":["Mechanical Engineering"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:01:17Z"}