{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/15911"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/15911","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"ENHANCEMENT OF DAMPING OF SYNCHRONOUS GENERATORS AND CONDENSERS","abstract":"An alternating current power system is semi-rigid and angular changes in voltages or shaft positions result from changes in load. Power systems are inherently lightly damped and changes in voltage or power give rise to oscillations which may be sustained and limited or may lead to system failure due to loss of synchronism. System oscillations are reflected in the shaft speed, the terminal voltage, the real power, the reactive power and the line current of each generator or motor. Extra damping can be introduced electrically through appropriate feedback into the generator exciter circuit. A great deal of research has been done on electrical damping, the results of which dominate the recent papers on power system stabilization. Currently investigations by industry are centred around finding the feedback signal that yields the highest damping. This thesis is a report of digital computer studies carried out by the author on systems which are now being employed by industry on a trial basis. Two state space models, simulating a hydraulic turbine-generator and a synchronous condenser from the Saskatchewan Power Corporation System are checked for stability to determine the relative merits of the various damping enhancement networks.","abstract_html":"An alternating current power system is semi-rigid and angular changes in voltages or shaft positions result from changes in load. Power systems are inherently lightly damped and changes in voltage or power give rise to oscillations which may be sustained and limited or may lead to system failure due to loss of synchronism. System oscillations are reflected in the shaft speed, the terminal voltage, the real power, the reactive power and the line current of each generator or motor. Extra damping can be introduced electrically through appropriate feedback into the generator exciter circuit. A great deal of research has been done on electrical damping, the results of which dominate the recent papers on power system stabilization. Currently investigations by industry are centred around finding the feedback signal that yields the highest damping. This thesis is a report of digital computer studies carried out by the author on systems which are now being employed by industry on a trial basis. Two state space models, simulating a hydraulic turbine-generator and a synchronous condenser from the Saskatchewan Power Corporation System are checked for stability to determine the relative merits of the various damping enhancement networks.","abstract_has_math":false,"creators":["Strmotich, Frank L."],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":null,"degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":["Fleming, R. J."],"committee_chairs":[],"committee_members":[],"year":1970,"date_issued":"1970-05","date_published":"1970-05","updated_at":"2026-11-19T10:13:48Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10388/15911","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/15911","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F15911","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F15911","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fleming, R. J."]},{"key":"dc:creator","label":"Author","values":["Strmotich, Frank L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-15T21:27:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-15T21:27:50Z"]},{"key":"dc:date.issued","label":"Date","values":["1970-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 1970"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/15911"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An alternating current power system is semi-rigid and angular changes in voltages or shaft positions result from changes in load. Power systems are inherently lightly damped and changes in voltage or power give rise to oscillations which may be sustained and limited or may lead to system failure due to loss of synchronism. System oscillations are reflected in the shaft speed, the terminal voltage, the real power, the reactive power and the line current of each generator or motor. Extra damping can be introduced electrically through appropriate feedback into the generator exciter circuit. A great deal of research has been done on electrical damping, the results of which dominate the recent papers on power system stabilization. Currently investigations by industry are centred around finding the feedback signal that yields the highest damping. This thesis is a report of digital computer studies carried out by the author on systems which are now being employed by industry on a trial basis. Two state space models, simulating a hydraulic turbine-generator and a synchronous condenser from the Saskatchewan Power Corporation System are checked for stability to determine the relative merits of the various damping enhancement networks."]},{"key":"dc:title","label":"Title","values":["ENHANCEMENT OF DAMPING OF SYNCHRONOUS GENERATORS AND CONDENSERS"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fleming, R. J."],"dc:creator":["Strmotich, Frank L."],"dc:date.accessioned":["2024-08-15T21:27:50Z"],"dc:date.available":["2024-08-15T21:27:50Z"],"dc:date.issued":["1970-05"],"dc:date.submitted":["May 1970"],"dc:description.abstract":["An alternating current power system is semi-rigid and angular changes in voltages or shaft positions result from changes in load. Power systems are inherently lightly damped and changes in voltage or power give rise to oscillations which may be sustained and limited or may lead to system failure due to loss of synchronism. System oscillations are reflected in the shaft speed, the terminal voltage, the real power, the reactive power and the line current of each generator or motor. Extra damping can be introduced electrically through appropriate feedback into the generator exciter circuit. A great deal of research has been done on electrical damping, the results of which dominate the recent papers on power system stabilization. Currently investigations by industry are centred around finding the feedback signal that yields the highest damping. This thesis is a report of digital computer studies carried out by the author on systems which are now being employed by industry on a trial basis. Two state space models, simulating a hydraulic turbine-generator and a synchronous condenser from the Saskatchewan Power Corporation System are checked for stability to determine the relative merits of the various damping enhancement networks."],"dc:identifier.uri":["https://hdl.handle.net/10388/15911"],"dc:title":["ENHANCEMENT OF DAMPING OF SYNCHRONOUS GENERATORS AND CONDENSERS"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:13:48Z"}