{"id":{"repo_id":"sask","oai_identifier":"oai:harvest.usask.ca:10388/16032"},"canonical_url":"https://search.ndltd.org/etd/sask/oai:harvest.usask.ca:10388/16032","repository":{"repo_id":"sask","name":"University of Saskatchewan","base_url":"https://harvest.usask.ca/server/oai/request"},"display":{"title":"Beam Transmission Efficiency Measurement of the Injector System of the Canadian Light Source for the Top-up Mode of Operation","abstract":"The beam transmission efficiency was measured in terms of charge through the CLS accelerator complex to determine the performance of the injector system for top-up operation. Propagation through the injection system incurs notable losses from bending magnets, beam choppers along the way and the transition from 2856MHz to 500MHz RF frequency at the injection point from the Linac-to-Booster transfer line (LTB) to the booster. The present system only monitors the efficiency of the booster to storage ring injection with two parametric current transformers (PCTs). In this experiment, the transmission efficiencies between four key points in the Linac and LTB were measured using fast current transformers (FCTs) along with the present system, which gives an overview of the total transmission efficiency from a very close point of the electron gun to the storage ring. The FCT signals were corrected for the loss attributed to the cable attenuation by employing Fast Fourier analysis and determining the cables’ S21-parameter. The charge calculation was improved by 3.3 − 7.5% with the corrected signals and the overall efficiency was found to be 16% ± 1% for top-up injection mode.","abstract_html":"The beam transmission efficiency was measured in terms of charge through the CLS accelerator complex to determine the performance of the injector system for top-up operation. Propagation through the injection system incurs notable losses from bending magnets, beam choppers along the way and the transition from 2856MHz to 500MHz RF frequency at the injection point from the Linac-to-Booster transfer line (LTB) to the booster. The present system only monitors the efficiency of the booster to storage ring injection with two parametric current transformers (PCTs). In this experiment, the transmission efficiencies between four key points in the Linac and LTB were measured using fast current transformers (FCTs) along with the present system, which gives an overview of the total transmission efficiency from a very close point of the electron gun to the storage ring. The FCT signals were corrected for the loss attributed to the cable attenuation by employing Fast Fourier analysis and determining the cables’ S21-parameter. The charge calculation was improved by 3.3 − 7.5% with the corrected signals and the overall efficiency was found to be 16% ± 1% for top-up injection mode.","abstract_has_math":false,"creators":["Rahman, Milad"],"institution":"University of Saskatchewan","degree_name":"Master of Science (M.Sc.)","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics and Engineering Physics","school":null,"contributors":[],"advisors":["Boland, Mark"],"committee_chairs":[],"committee_members":["Smolyakov, Andrei","Degenstein, Doug","Pywell, Rob","Achenbach, Sven"],"year":2024,"date_issued":"2024-09-16","date_published":"2024-09-16","updated_at":"2026-11-19T10:00:54Z","subjects":["CLS","Transmission Efficiency","Top-up Injection"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0009-0002-5516-7089"],"render_values":[{"text":"0009-0002-5516-7089","href":"https://orcid.org/0009-0002-5516-7089","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/10388/16032","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10388/16032","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Asask%3Aoai%3Aharvest.usask.ca%3A10388%2F16032","prefix":"oai_dc"},"source_record":{"url":"https://harvest.usask.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aharvest.usask.ca%3A10388%2F16032","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Boland, Mark"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Smolyakov, Andrei","Degenstein, Doug","Pywell, Rob","Achenbach, Sven"]},{"key":"dc:creator","label":"Author","values":["Rahman, Milad"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0009-0002-5516-7089"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-09-16T21:13:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-09-16T21:13:08Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2024"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-09"]},{"key":"dc:date.issued","label":"Date","values":["2024-09-16"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["September 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-09-16T21:13:08Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_department","label":"Department","values":["Physics and Engineering Physics"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Saskatchewan"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["CLS","Transmission Efficiency","Top-up Injection"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10388/16032"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The beam transmission efficiency was measured in terms of charge through the CLS accelerator complex to determine the performance of the injector system for top-up operation. Propagation through the injection system incurs notable losses from bending magnets, beam choppers along the way and the transition from 2856MHz to 500MHz RF frequency at the injection point from the Linac-to-Booster transfer line (LTB) to the booster. The present system only monitors the efficiency of the booster to storage ring injection with two parametric current transformers (PCTs). In this experiment, the transmission efficiencies between four key points in the Linac and LTB were measured using fast current transformers (FCTs) along with the present system, which gives an overview of the total transmission efficiency from a very close point of the electron gun to the storage ring. The FCT signals were corrected for the loss attributed to the cable attenuation by employing Fast Fourier analysis and determining the cables’ S21-parameter. The charge calculation was improved by 3.3 − 7.5% with the corrected signals and the overall efficiency was found to be 16% ± 1% for top-up injection mode."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Beam Transmission Efficiency Measurement of the Injector System of the Canadian Light Source for the Top-up Mode of Operation"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Boland, Mark"],"dc:contributor.committeemember":["Smolyakov, Andrei","Degenstein, Doug","Pywell, Rob","Achenbach, Sven"],"dc:creator":["Rahman, Milad"],"dc:date.accessioned":["2024-09-16T21:13:08Z"],"dc:date.available":["2024-09-16T21:13:08Z"],"dc:date.copyright":["2024"],"dc:date.created":["2024-09"],"dc:date.issued":["2024-09-16"],"dc:date.submitted":["September 2024"],"dc:date.updated":["2024-09-16T21:13:08Z"],"dc:description.abstract":["The beam transmission efficiency was measured in terms of charge through the CLS accelerator complex to determine the performance of the injector system for top-up operation. Propagation through the injection system incurs notable losses from bending magnets, beam choppers along the way and the transition from 2856MHz to 500MHz RF frequency at the injection point from the Linac-to-Booster transfer line (LTB) to the booster. The present system only monitors the efficiency of the booster to storage ring injection with two parametric current transformers (PCTs). In this experiment, the transmission efficiencies between four key points in the Linac and LTB were measured using fast current transformers (FCTs) along with the present system, which gives an overview of the total transmission efficiency from a very close point of the electron gun to the storage ring. The FCT signals were corrected for the loss attributed to the cable attenuation by employing Fast Fourier analysis and determining the cables’ S21-parameter. The charge calculation was improved by 3.3 − 7.5% with the corrected signals and the overall efficiency was found to be 16% ± 1% for top-up injection mode."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10388/16032"],"dc:language.iso":["en"],"dc:subject":["CLS","Transmission Efficiency","Top-up Injection"],"dc:title":["Beam Transmission Efficiency Measurement of the Injector System of the Canadian Light Source for the Top-up Mode of Operation"],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"person:identifier.orcid":["0009-0002-5516-7089"],"thesis:degree_department":["Physics and Engineering Physics"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.Sc.)"],"thesis:institution_name":["University of Saskatchewan"]},"updated_at":"2026-11-19T10:00:54Z"}